Home Companies Tianjin Estel Electronic Science and Technology Co.,Ltd

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

Tianjin Estel Electronic Science and Technology Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Shenzhen, China

Contact name:Fiona Liang

Inquir Now

Tianjin Estel Electronic Science and Technology Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

Country/Region china
City & Province shenzhen guangdong
Categories Other Surveillance Products
InquireNow

Product Details

 

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

 

Quick Details:

 

Place of Origin: Shenzhen, China (Mainland)Communication Interface: RS485, Ethernet, RS485/232 multiplex
Brand Name: ESTELAnalog Input: four ways
Model Number: NEM-500Digital Input: eight ways
Product Name: Environment Monitoring SystemDry contact (relay) output:eight ways
Certification: ISO9001, CE, 3C, FCC, TLCOperating Voltage: 85 VAC~300 VAC, or 20 VDC~ 60 VDC
Application: Outdoor Telecom CabinetAlarm Sensors: door sensor, smoke sensor, water sensor, temperature and humidity sensor, tilt & shock combination sensor

 

Payment & Shipping Terms:

 

Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:L/C, D/A, D/P, T/T, Western Union
Supply Ability:20,000 sets per month
Delivery Time:7-10 working days
Packaging Details:carton/wooden case

 

1. Description

 

The NEM-500 is a small high-reliability environment monitoring unit developed to provide environment/device control and remote monitoring for communications base stations, integrated equipment rooms, and out-door cabinets.

The monitoring unit monitors important environmental factors such as temperature, humidity, smog, water penetration, access control, vibration/leaning, main distribution frame (MDF), and surge protection device (SPD). When any value collected by a sensor exceeds the preset threshold, an alarm is sent through the LCD, buzzer, or system log.

The monitoring unit also provides complete device detection functions, such as switch power status detection. Through a preserved custom interface (optional), the unit can be connected to another sensor in main contact point output type.

 

 

2. Product Appearance

 

Chassis dimensions (H x W x D) are 43.6 mm (1U) x 482.6 mm (19 inches) x 122 mm. Front cabling is adopted. The following shows the front panel of the chassis:

 

 

Note: The diagram is for reference only and the dimensions may be different from those of the real device. Note: In this document, transmitter, sensor, and integrated transmitter have the same meaning.

 

Interface specifications

 

1.)Power switch

 

It is used to power on/off the device.

 

2.)Power interface

 

This device can be powered by AC or DC power supply.

AC voltage range: 85 VAC to 300 VAC;

DC voltage range: 20 VDC to 60 VDC

 

3.)Liquid crystal display (LCD)

 

It displays sensor status data and parameter configuration pages.

 

4.)Buttons

 

They are used together with the LCD for menu page up/down and parameter settings.

 

UP: Go to the previous page up (when viewing), or increase the parameter value (when setting);

DOWN: Go to the next page up (when viewing), or decrease the parameter value (when setting);

OK: Confirm the selection of a menu option (when viewing), or of a parameter value (when setting).

 

5.)LEDs

 

They show the operation and alarm status of the monitoring unit.

 

Power LED: It indicates that the device is powered on and running;

Minor alarm: It indicates a minor alarm;

Major alarm: It indicates a major alarm.

 

6.)Sensor input interfaces

 

Four current-type analog input ports, with 12 VDC power ports connected to temperature, or temperature and humidity combination sensors;

 

 Eight switch (dry contact) input ports, three of which with 12 VDC power ports connected to access control, smog detector, infrared detector, or SPD sensors;

 

8.)Dry contact (relay) output interfaces

 

Eight ports are available to send alarm signals to the upper-level alarm center, or to control the device’s startup/close-down.

You can customize alarm rules, and associate any alarm signal with a relay among O1 to O8. Ports O1 to O4 output switch signals;

Ports O5 to O8 control large-current devices such as fans and heaters.

 

9.)RS485/RS232/Ethernet interfaces

 

Four ports: A is an optional Ethernet port; B and C are fixed RS485 ports; D is an RS485/RS232 multiplex port that can be set to work in either RS485 or RS232 mode. Port A, D can be switch by the system automatically.

 

Ports A and D are used to connect the remote computer or alarm center device;

Ports B and C are used to connect other RS485-interface devices, such as the switch power, air conditioners, heat exchangers, and temperature and humidity sensors. (Note: Transparent data transmission and forwarding are supported. The complete monitoring functionality is to be developed based on standard communications protocols.)

 

Configuration and cabling diagram:

 

 

Specifications of the Environment Monitoring System

 

Model

NEM-510

NEM-520

NEM-530

Analog input port (4 mA to 20 mA)

4

4

4

Dry contact (Digital) input port

8

8

8

AC voltage detection (single phase)

/

1

1

DC voltage detection

1

1

1

Dry contact (relay) output port

8

8

8

RS485 interface (fixed)

2

2

2

RS485/RS232 multiplex interface for uploading (Can switch between RS485/RS232)

1, fixed to RS485

1, RS485/RS232

multiplex

1, RS485/RS232

multiplex

Ethernet

1, optional

1, optional

1, optional

Water detection sensor module

Supported,

optional

Supported,

optional

Supported,

optional

Thermostat (Control fans)

 

/

Supported,

optional

Supported,

optional

Thermostat (Control heater)

 

/

Supported,

optional

Supported,

optional

AC power (220 V) supply

Supported,

optional

Supported,

optional

Supported,

optional

DC power (48 V) supply

Supported,

optional

Supported,

optional

Supported,

optional

Remote computer monitoring software

 

 

 

Controllable heat exchanger

 

/

 

/

Supported,

optional

Monitored air conditioner

 

/

 

/

Supported,

optional

Monitored switching power

 

/

 

/

Supported,

optional

Monitored Smart Air-Conditioning

Remote Control

 

/

 

/

Supported,

optional

 

3. Features

 

3.1 Front maintenance (front cabling): higher space utilization and easy maintenance

3.2 Combat structure: standard 1U/19-inch chassis for easy installation

3.3 Monitoring of cabinet switch power: The monitoring unit can be connected to the switch power for transparent data transmission and forwarding. The complete monitoring functionality is to be developed based on standard communications protocols.

3.4 Uploading over standard protocols: The monitoring unit uploads environment data to the monitoring background and receives remote system commands over specified protocols in main contact point or RS485/232/IP mode.

3.5 Complete monitoring functionality: The monitoring unit intelligently controls all environment devices in an equipment room, and automatically monitors environment parameters against the alarm thresholds from remote.

3.6 GUI-based host computer control software:

3.7 Various sensors supported: The monitoring unit can be connected to various analog-output sensors, switch-output sensors, and RS232, RS485 interface sensors.

3.8 Built-in common sensors for simplified cabling during monitoring system installation Optional built-in DC power failure sensor, AC power failure sensor, and water sensor

3.9 Flexible power supply mode: voltage range as 85 VAC to 300 VAC, or 20 VDC to 60 VDC

 

4. Product Specifications

 

Environment variables

 

No.VariableSpecificationDescription
1

Temperature

 

/Humidity

4

Four port supports 4 mA to 20 mA current-type sensor;

The port supports 4 temperature sensor, or 2 temperature/humidity combination sensor.

2Water detection2

Leaking and water penetration detection

 

One port has a built-in sensor and you only need to connect the outside of the chassis to the pole;

The other external port is connected to the external water sensor

 

(Dry contact interface).

3Access control1Door status (open/close) detection
4Smoke1Smoke and fire detection
5AC power failure alarm1

Single-phase AC voltage detection

One sensor is built in and the AC power cable must be connected to the local detection terminal.

6DC power failure alarm1

DC voltage detection

One sensor is built in and the DC power cable must be connected to the local detection terminal.

7SPD1SPD status detection (Dry contact interface)
8MDF1MDF status detection
9Switching power1

Switching power status detection (RS485 connection in standard configuration)

Optional RS232 serial port connection (through RS485-RS232

 

No.VariableSpecificationDescription
   

Converter)

Transparent data transmission and forwarding are supported. The complete monitoring functionality is to be developed based on standard communications protocols.

10Custom2

One port is connected to the switching power failure sensor (Dry contact interface) by default;

The other port is connected to a custom dry contact type sensor,

 

with 12 V power supply for external sensors.

 

Output ports

 

No.VariableSpecificationDescription
1Dry contact output8

Custom output signal type:

 

O1/O2/O3/O4 are small-current output ports;

O5/O6/O7/O8 are large-current output ports, with relay contact capacity as 5 A 250 VAC and 5 A 30 VDC.

 

Communication ports

 

Four ports are configured as follows:

 

No.Interface TypeSpecificationDescription
1RS4852

It is connected to the RS485 port of an intelligent device. Transparent data transmission and forwarding are supported. The complete monitoring functionality is to be developed based

on standard communications protocols.

2Ethernet1 (optional)

It is connected to a remote computer or alarm center over

 

TCP/IP.

3

RS485/232

 

multiplex

1

It is connected to a remote computer or alarm center.

 

The interface type is RS232 or RS485 (RS485 by default).

 

Note: Items 2 and 3 cannot coexist.

 

5. Functions

 

  • Signal collection function

The monitoring unit collects data of environment variables (such as temperature, humidity, smog) and device variables (such as switch power), passes the data for multipoint control unit (MCU) processing and analysis, and shows the equipment room status on the local liquid crystal display (LCD) or remote computer;

  • Alarm function

An alarm is sent when any value collected by a sensor exceeds the preset threshold;

 

  • History record function

Historical alarms can be queried.

 

  • Local or remote control function

Local users can press the front panel buttons to query and set parameters and data;

The monitoring unit communicates with the host computer through the Ethernet (IP)/RS232/RS485/main contact point interface, and the host computer can read all status data of the monitoring unit and modify system settings from remote.

The remote control software for the host computer is optional.

 

6. Packing and Shipping

 

 

 

Our Delivery Agent

 

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

 

7. Our Contact Information

 

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

           lxf.estel@hotmail.com
Skype: fiona.liang10

Hot Products

Custom Environment Monitoring System Spot-Type Photoelectric Smoke Sensor Detector Quick Details ...
ABS Housing Environment Monitoring System Door Sensor / Alarm Reed Switch Quick Details Place of ...
Remote Monitoring Environment / Security Monitoring System Support RS485 RS232 Quick Details: Place ...
Environment Monitoring System Intelligently Turn On / Turn Off LED Lamp Quick Details: Place of ...
Environmental Monitoring Sensors , Water Sensor Switch For Alarming Water Level Inside Cabinet Quick ...
Professional Environment Temperature And Humidity Sensor Low Power Consumption Quick Details: Place ...