Bipolar Vacuum Transformer Oil Purifier Machine 12000Liters/Hour
Application:
Bipolar Vacuum Transformer Oil Purifier Machine
12000Liters/Hour, Oil Flow Variable from 0~12000Liters/Hour, High Vacuum Transformer
Oil Filtration Machine ZYD-200 is mainly used for electric power department and industries to deal
with various oils such as transformer oil, mutual oil, switch oil,
insulating oil, dielectric oil and so on. The machine is especially
for purifying the insulation oil in all kinds of large power
equipments that are above 110KV, especially for the altitude is
over 500-1000 meters. It can remove the free and dissolved water, gas and particles from oil high-efficiently, increasing the
pressure force and quality of oil, make sure the electric device
running safely. The dielectric value of treated oil is higher than 75~85KV. It is
very suitable for the large electric&insulation equipments.
What ZYD can do for you?
1.Removes water, trace water from oil completely
2. Remove impurities from transformer oil fast
3. Reduces combustible gases and oxygen to standard value
4. Improves oil dielectric values
5. Improves transformer power factor
6. Extends oil service life
7. Extends transformer service life and reliability
Features:
1. Two pumps: vacuum pump and booster pump
2. Three-stage filter system
3. Z-shape Heater to make the heating uniformity
4. Installing oil-level floating ball and double-infrared liquid
level automatic controller to control the oil level
5. Foam sensor to avoid oil leaking
6. Temperature Controller to protect the machine
7. Suitable oil filtration machine for high voltage transformer
8. Large filtration area, high capacity of holding impurities
9. Two vacuum separator to increase separating size and time.
10. Doing online oil purification of substations over 110 KV.
11. Independent function of vacuum oil filling and drying.
12. Duplex stereo flash evaporation technology
13. Equipped with pressure protective system and interlocked
protective system to connect oil pump, heater and liquid level
controller. If there has any fault, it will be power off
automatically.
14. Saving energy and time
Technical Parameters:
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working Vacuum | Mpa | -0.08 ~-0.099 | |||||||
Working Pressure | Mpa | ≤ 0.3 | |||||||
Temp Range | ℃ | 20 ~80 | |||||||
Power Supply | 380V, 50Hz, 3Phase( As per required) | ||||||||
Working Noise | Db | 60 - 80 (Depended on the configuation) | |||||||
Heating Power | KW | 30 | 60 | 90 | 135 | 150 | 165 | 180 | |
Total Power | KW | 35 | 67.5 | 101.5 | 149 | 164 | 198 | ||
Inlet/Outlet Diam | MM | 25 | 32 | 42 | 50 | 50 | 60 | 60 | |
Weight | KG | 450 | 550 | 750 | 950 | 1200 | 1850 | 2000 | |
Size | Length | MM | 1450 | 1450 | 1750 | 1850 | 1950 | 2050 | 2150 |
Width | MM | 950 | 1000 | 1250 | 1300 | 1350 | 1400 | 1450 | |
Height | MM | 1700 | 1750 | 1950 | 2000 | 2050 | 2100 | 2150 | |
AFTER TREATMENT | |||||||||
Dielectric Strength | KV | ≥ 75-85 | |||||||
Water Content | PPM | ≤ 3 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Particle Size | μ | ≤ 3 | |||||||
Cleanliness ≤NAS 1638 Grade 5 |