Chongqqing Rexon Oil Purification Co., Ltd |
|
Fully Enclosed Type Onsite Power Station Use Transformer Oil Purifier Machine 9000Liters/Hour
Product Introduction:
Our vacuum transformer oil purifier is developed on the
characteristics of oil for electricity, especially for special
high-voltage transformer above 110kv facilities. We developed the
most advanced and the best special insulating oil treatment
equipment successfully. Oil purification standard reaches
Q/GDW122-2005. After several improvements, the device has reached
domestic leading level and international similar products in the
same performance parameters, with a high price-performance ratio.
This product is a combination of the international advanced film
theory and atomized oil treatment technology, with a highly
efficient degassing dehydration and breaking emulsification effect.
Oil in this system is fully thin-film (Oil exposed area are fully
expanded), and oil is increased the "journey", so that water or gas
in oil is vaporized for sufficient time to reach the best effect of
dehydration degassing.
The device uses electronic anti-foaming devices and high efficiency
of the needle breaking foam technology to eliminate foam (patented
technology) and make no "injection" phenomenon during operation.
Adopting the "Y-type" gear pump, guide wheel technology (patented technology) and VFD
driving technology, we solved oil-drain problems in high-vacuum and
noise problems.
Application:
Fully Enclosed Type Onsite Power Station Use Transformer Oil
Purifier Machine 9000Liters/Hour, High Vacuum Transformer Oil
Filtration Machine ZYD-150 is mainly used for electric power department and industries to deal
with various oils such as transformer oil, mutual oil, switch oil,
insulating oil, dielectric oil and so on. The machine is especially
for purifying the insulation oil in all kinds of large power
equipments that are above 110KV, especially for the altitude is
over 500-1000 meters. It can remove the free and dissolved water, gas and particles from oil high-efficiently, increasing the
pressure force and quality of oil, make sure the electric device
running safely. The dielectric value of treated oil is higher than 75~85KV. It is
very suitable for the large electric&insulation equipments.
Features:
1. Double-stage vacuum system, strong power of vacuum evacuating,
ultimate vacuum value ≤ 5Pa.
2. Big capacity of moisture ands gas separating chambers, efficient
oil film sprayer, increasing separating size and separating time to
ensure the dry-level and dielectric strength of oil improving
greatly.
3. Duplex-Stereo film evaporation technology, combined with unique
and advanced dewatering, degassing components, can rapidly and
effectively separate water, gas from oil.
4. Multi-stage precision filtration system, mesh filtration
combined with molecular adsorption technologies, which can purify
oil high efficient and make oil highly pure.
5. Efficient electric heating system, heating uniformity, less
power consumption, safe, and reliable.
6. Double-infrared liquid level sensor, pressure protective system
and foaming elimination system to ensure machine operating easy and
safely.
7. Adopt interlocked protective system, which connect oil pump,
heater and liquid level sensor, avoiding blank heating, blank
pumping, oil leak and electricity leak. If there is any fault,
machine will be power off automatically.
8. It can be operated both online and offline of transformers.
9. Can be used independent device for vacuuming transformers which
are above 110KV and can vacuum oil filling for power equipment.
10. Can work online for 150 hours continuously, high reliable and
long time running.
11. Can be installed by PLC programming control system to achieve
machine working fully automatically.
Advantage:
Fully Enclosed Type Onsite Power Station Use Transformer Oil
Purifier Machine 9000Liters/Hour, High Vacuum Transformer Oil
Filtration Machine ZYD-150, it can be used for every different
model from 0~9000Liters/Hour. Oil flow rate changeable easily. It
can quickly remove water, trace water, dissolved gas, particles as
well as acetylene, hydrogen, methane and other harmful ingredients
from oil effectively to improve oil's dielectric strength,
effectively making sure electric equipments working safely and
normally. As the bridge-type vacuum linking system that also can be an
independent vacuum power supply, which can vacuuming and oil
injecting for electric insulation devices.
The oil technical data after treatment:
1. Gas content is less than 0.1%
2. Impurity size is less than 1μm without free carbon
3. Water content is less than 3 part per million
3. Oil dielectric strength (breakdown voltage) is more than 75KV
4. Acidity value is less than 0.01 mg KOH/g
5. Dielectric loss factors at 90℃ is less than 0.001
(oil filtration, oil purification, oil treatment, oil purifier, oil recycling, oil processing, oil filtering, oil filtration, energy saving, oil regeneration, oil processor, oil filter, oil process, oil purify, oil regenerating, oil restoration, waste oil disposal, oil reclaimed, oil reclaiming, waste oil management, oil regenerate, oil reconditioned, oil reconstituted, oil restituting, oil recovering, oil recondition, oil filters, oil refinery, oil refiner, oil cleaning, oil recycle, oil reclaiming, oil separator, oil recovery, oil recycle, oil reclamation, oil refinery, oil separator, oil separation, oil purifiers, oil recondition )
Technical Parameters:
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working Vacuum | Mpa | -0.08 ~-0.099 | |||||||
Working Pressure | Mpa | ≤ 0.3 | |||||||
Temp Range | ℃ | 20 ~80 | |||||||
Power Supply | 380V, 50Hz, 3Phase( As per required) | ||||||||
Working Noise | Db | 60 - 80 (Depended on the configuation) | |||||||
Heating Power | KW | 30 | 60 | 90 | 135 | 150 | 165 | 180 | |
Total Power | KW | 35 | 67.5 | 101.5 | 149 | 164 | 198 | ||
Inlet/Outlet Diam | MM | 25 | 32 | 42 | 50 | 50 | 60 | 60 | |
Weight | KG | 450 | 550 | 750 | 950 | 1200 | 1850 | 2000 | |
Size | Length | MM | 1450 | 1450 | 1750 | 1850 | 1950 | 2050 | 2150 |
Width | MM | 950 | 1000 | 1250 | 1300 | 1350 | 1400 | 1450 | |
Height | MM | 1700 | 1750 | 1950 | 2000 | 2050 | 2100 | 2150 | |
AFTER TREATMENT | |||||||||
Dielectric Strength | KV | ≥ 75-85 | |||||||
Water Content | PPM | ≤ 3 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Particle Size | μ | ≤ 3 | |||||||
Cleanliness ≤NAS 1638 Grade 5 |
REXON Fully Automatic PLC Type Transformer Oil Filtration Machine
is a fully automatic transformer oil purification processing
equipment. With one button start, the machine runs automatically,
without the need for the operator to guard the machine and liberate
the labor. The fully automatic PLC type oil filter machine is easy
to use and easy to maintain. It is a transformer maintenance
equipment that is very suitable for on-site processing of
transformer oil.