Fully Enclosed Type Power Substation Used Transformer Oil Filtration Machine 3000LPH~18000LPH
 

Application:
Fully Enclosed Type Power Substation Used Transformer Oil Filtration Machine 3000LPH~18000LPH, Transformer Oil Filtration Plant uses big capacity vacuum pump with Big Model Roots Vacuum Pump is mainly used for removing trace water, gas and impurities from insulating dielectric oil, improving the insulating oil performance index. It is mainly applied to purification for high voltage insulating oil of 110KV,220KV,500KV,750KV,1000KV from power transmission equipment.
Feature:
1. Especially for removing water from transformer oil, such as free water, trace water and so on by the double stage vacuum system for high voltage oil.
2. Remove gas, air content from the old high voltage transformer oil by vacuum degassing system.
3. Remove impurities, tiny particles, acidity, sludge, free carbon, other soluble oil decay products and discoloration substances by 3 stages of filters (Primary filter, secondary filter, fine filter).
4. Independent vacuum oiling system for transformers, this oil purifier can also vacuum dry transformer and on-line operation with transformers.
5. Designed for processing high voltage insulating oils in workshops, onsite power stations, purifying oil in oil storage tanks or directly in transformers(energized or de-energized transformers).
6. Efficient electric heating system, heating uniformity, less power consumption, safe, and reliable.
7. Double-infrared liquid level sensor, pressure protective system and foaming detecting and eliminating to ensure machine operation easily and safely.
8. Adopt interlocked protective system, which connect oil pump, heater and liquid level sensor, avoiding blank heating, blank pumping.
 

Advantage:
Fully Enclosed Type Power Substation Used Transformer Oil Filtration Machine 3000LPH~18000LPH, High Voltage Transformer Oil Purifier Machine Model ZYD is particularly suitable for filtering high-grade transformer oil, super-voltage transformer oil and new transformer oil. It can be used for filtration of more than 110V substation live line work onsite. It's particularly suitable for treating high-grade transformer oil, super-voltage transformer oil and new transformer oil. It can be used for filtration of more than 110V substation live line work on-site. Meanwhile, it can be used as independent vacuum resource with functions of vacuum drying and vacuum oiling.
 
Technical Parameters:

ParametersUnitZYD-30ZYD-50ZYD-100ZYD-150ZYD-200ZYD-250ZYD-300
Flow RateL/H1800300060009000120001500018000
Working VacuumMpa-0.08 ~-0.099
Working PressureMpa≤ 0.3
Temp Range20 ~80
Power Supply 380V, 50Hz, 3Phase( As per required)
Working NoiseDb60 - 80 (Depended on the configuation)
Heating PowerKW306090135150165180
Total PowerKW3567.5101.5149164 198
Inlet/Outlet DiamMM25324250506060
WeightKG450550750950120018502000
SizeLengthMM1450145017501850195020502150
WidthMM950100012501300135014001450
HeightMM1700175019502000205021002150
AFTER TREATMENT
Dielectric StrengthKV≥ 75-85
Water ContentPPM≤ 3
Gas Content%≤ 0.1
Particle Sizeμ≤ 3
Cleanliness ≤NAS 1638 Grade 5


 

REXON high vacuum dehydration transformer oil filtration machine adopts two-stage high vacuum system, high efficiency three-stage filter system, high-power low-temperature heating system, constant temperature heating control system, intelligent electronic control system, PLC control system, automatic oil level The detection system, the vacuum detection system, and the safety protection system, etc., REXON machines are constructed using the latest oil filtering technology and internationally renowned brand accessories.
 
The oil technical data after treatment:
1. Gas content is less than 0.1%
2. Impurity size is less than 1μm without free carbon
3. Water content is less than 3 part per million
3. Oil dielectric strength (breakdown voltage) is more than 75KV
4. Acidity value is less than 0.01 mg KOH/g
5. Dielectric loss factors at 90℃ is less than 0.001
 
(oil filtration, oil purification, oil treatment, oil purifier, oil recycling, oil processing, oil filtering, oil filtration, energy saving, oil regeneration, oil processor, oil filter, oil process, oil purify, oil regenerating, oil restoration, waste oil disposal, oil reclaimed, oil reclaiming, waste oil management, oil regenerate, oil reconditioned, oil reconstituted, oil restituting, oil recovering, oil recondition, oil filters, oil refinery, oil refiner, oil cleaning, oil recycle, oil reclaiming, oil separator, oil recovery, oil recycle, oil reclamation, oil refinery, oil separator, oil separation, oil purifiers, oil recondition )

 































Hot Products

Fully Enclosed Type Onsite Power Station Use Insulating Oil Purification Plant 9000Liters/Hour ...
Fully Enclosed Type Bipolar Vacuum Transformer Oil Filtration Machine 12000Liters/Hour Technical ...
Fully Enclosed Type High Vacuum Dehydration Insulation Oil Purification System 9000LPH Application: ...
Fully Enclosed Type Vacuum Processing Insulating Oil Filtration System Dewater and Degas from Oil ...
Fully Enclosed Type Power Substation Used Transformer Oil Filtration Machine 3000LPH~18000LPH ...
Fully Enclosed Type High Efficiency Vacuum Dielectric Oil Purification Machine for Power Plant ...