Results fornes 714 loifrom 17 Products.
|
LOI Limited Oxygen Index Meter Introduction Limited Oxygen Index Meter measures minimum oxygen concentration as necessary when specimen combustion. This oxygen sensor is Paramagnet...
|
|
|
|
Intelligent Automatic Touch-Screen Control Oxygen Index Tester I. Intelligent Full-automatic Touch Screen Control Oxygen Index Tester Product Advantages: 1. Full-color touch screen ...
|
|
|
|
Paramagnetic Limited Oxygen Index Meter Introduction Limited Oxygen Index tester measures minimum oxygen concentration as necessary when specimen combustion. The oxygen sensor is ...
|
|
|
|
Paramagnetic Method Limited Oxygen Index Tester -- Model COI Introduction: COI Oxygen Index tester measures minimum oxygen concentration as necessary when specimen combustion. ...
|
|
|
|
Accord with standard:GB/T 2406.2-2009 GB/T 5454 ISO 4589-2-2006 ASTM D2863 NES 714 Technology data: 1.) test range:0~100% 2.) working pressure:0.05-0.3Mpa 3.) height of combustion ...
|
|
|
|
Introduction: This Critical Limiting Oxygen Index Apparatus measures minimum oxygen concentration as necessary when specimen combustion. The oxygen sensor is adapted Paramagnetic ...
|
|
|
|
Introduction: This Minimum Oxygen Index Test Apparatus measures minimum oxygen concentration as necessary when specimen combustion. The oxygen sensor is adapted Paramagnetic Type ...
|
|
|
|
Introduction: This fully automatic Oxygen Index Measuring Instrumentmeasures minimum oxygen concentration as necessary when specimen combustion. The oxygen sensor is adapted ...
|
|
|
|
LOI Limited Oxygen Index Tester Introduction Limited Oxygen Index tester measures minimum oxygen concentration as necessary when specimen combustion. This oxygen sensor is ...
|
|
|
|
Economic Type Electrochemistry Method Oxygen Index Tester -- Model LOI Introduction: OI Oxygen Index tester measures minimum oxygen concentration as necessary when specimen ...
|
|
|
|
ASTM D 2863 ISO 4589-2 Digital Oxygen Index Tester Applications measures minimum oxygen concentration as necessary when specimen combustion. This equipment’s the oxygen analyser is ...
|
|
|
|
Automatic Limited Oxygen Index Tester , Standard ISO4598-2 Oxygen Testing Machine Model:5801A Accord with standard:GB/T 2406.2-2009 GB/T 5454 ISO 4589-2-2006 ASTM D2863 NES 714 ...
|
|
|
|
School Laboratory Astm D 2863 Temperature Index Standard Iso 4598-2 1 Year Warranty Main configure: Portable ignition device Handheld point guns High temperature resistant quartz ...
|
|
|
|
Limited oxygen index tester 5801A Description : Put the sample fixed in a transparent combustion cylinder of upward flowing oxygen andnitrogen mixture,ignite top of sample and ...
|
|
|
|
Plastic Textile Rubber Oxygen Index Apparatus Standard ISO4598-2 Fire Resistance Material Support Test range 0-100% Work pressure 0.05-0.3Mpa Resolution 0.1% Test precision +-0.2% ...
|
|
|
|
Model:5801A Accord with standard:GB/T 2406.2-2009 GB/T 5454 ISO 4589-2-2006 ASTM D2863 NES 714 Technology data: Technology data: 1.) test range:0~100% 2.) working pressure:0.05-0...
|
|
|
|
Flammability Test Apparatus For Limited Oxygen Index Tester Model:5801A Accord with standard:GB/T 2406.2-2009 ISO 4589-2-2006 ASTM D2863 NES 714 Technology data: 1.) test range:0...
|
|
|
You may also be interested in :