Nitrogen generator membrane unit for sale with CE/ASME 500 CFM purity 99% 300 bar

How does membrane technology work?

Membrane nitrogen generators are based on a simple working principle. The main part of a membrane generator is the membrane module (+- 10cm in diameter), filled with small, hollow polymer fibers. First, dry, clean compressed air enters and due to the structure of these fibers parts of the air will flow to the outside of the fiber. This process is called permeation. During this process, water, oxygen and some of the argon exit through the membrane sides of the fibers. In the end, only nitrogen will remain. This is possible since different molecules permeate at different speeds. H2O will permeate very quickly, oxygen takes a little longer. Argon and Nitrogen permeate rather slowly, meaning that they will remain in the fibers long after the H2O and oxygen are gone (some of the Argon will permeate as well, but it would be inefficient to completely remove it from the air stream). Learn more about Nitrogen purity here. Because of the permeation through the fiber wall, an overpressure would occur inside the membrane housing. The fibers would clog and the permeation efficiency would be significantly lowered. To prevent that from happening there is an opening in the housing, the permeate vent, where these 'exhaust' gases (including H2O, oxygen and Argon) can escape.

Nitrogen purity and requirements for the intake air

It is very important for the intake air to be clean and dry before it enters the membrane. If this is not the case, the shallow fibers will quickly clog. In order to prevent this from happening, correct air treatment of the feed air has to be installed. In some cases the needed filters and dryers will already be built into the generator itself. This would mean that, in some cases, no additional filters should be installed between the compressor and generator. The fibers of the membrane can handle water vapor without much problems. It is however very important that the air doesn't contain liquid water, since this will have a detrimental impact on the membrane. Therefore, it is required for a good water separation solution to be in place upstream the generator, a refrigerant dryer for example. Taking care of the intake air of the generator will protect the membrane and ensure a long lifetime. Take a look at a typical installation below.

Choosing between a Membrane and PSA generator

Since the air factor is generally lower in PSA generators, which results in lower operating costs, you might think that choosing between the two is an easy choice. However, there are some notable advantages to using a membrane generator. The first one being the simpler working principle of membrane generators, this affects maintenance costs and results in a smaller footprint of the installation. They also start up faster and are a lot quieter than PSA generators, who typically have to cope with their blow-off noises at the end of each cycle. This last advantage makes a membrane nitrogen generator more suitable for places in which there are a lot of people working. When selecting the right type of generator, it's wise to look at the application it will be used for and then, considering the total package of (dis)advantages, make a choice.
 

 
 

ItemNitrogen purity (Nm3/hr)Dimensions

Weight
 

90%95%99%99.5%99.9%(L*W*H) mmKG
OSM151356123156.5450*300*1300100
OSM30270122463013550*500*1300140
OSM60540244926026900*850*1300200
OSM1201080488184120521200*1000*1500280
OSM1801620732276180781500*1200*1500400
OSM24018908543222401041800*1200*1600520
OSM300270012204603001302300*1350*1800600
OSM450405018306904501953850*1500*2000800
OSM52547252135805525227.54200*1550*2100950
OSM600540024409206002605000*1800*22501050
OSM675607527451035675292.55500*1800*23501250
OSM7506750305011507503255850*1850*24001500
OSM9008100366013809003906500*1950*24001700
OSM105094504270161010504557800*2100*24501950
OSM15001350061002300150065010500*2300*26002100
OSM180016200

7320
 

2760180078013000*2350*26002600

 
Design reference :
Compressed air inlet pressure 9 bar(g)/130 psi(g)
Air quality 1.4.1 according to ISO 8573-1:2010
Nitrogen outlet pressure 7 bar(g)/101psi(g)
Nitrogen quality 1.2.1 according to ISO 8573-1:2010.
Designed working temperature max 50 ℃
Dew point at Nitrogen outlet - 50 ℃
 
Notes:
Compressed air inlet pressure decide membrane performance
Following request of membrane nitrogen generator will be customized :
Compressed air pressure >14 bar(g)/203 psi(g) max up to 24 bar(g)/350 psi(g)
Working pressure >24 bar(g)/350 psi(g)
Dew point < - 50 ℃
Movable/containerized , plug and play
Diesel drive
Other special requirements as per site conditions
 
 

 


























Hot Products

2500CFM OSM serizes membrane nitrogen generator for oil and gas by diesel /electrical driving CE ...
Aircraft Fuel Tank Inserting membrane nitrogen generator pressure 500 psi purity 95%-99.9% by ASME...
Beverage manufacturing membrane nitrogen generator for food industry with capacity 300 scfm 100 psi ...
Membrane modular N2 generator for the Bacteria Elimination with capacity 500 scfm purity 95% 500 psi ...
Nitrogen generator membrane unit for sale with CE/ASME 500 CFM purity 99% 300 bar How does membrane ...
On-site membrane making own nitrogen generator by ASME certificates & CE fully automatic model ...