Medenstar Co.Ltd |
|
Led Dental Handpiece
Description:
Led Handpiece(Self Illimination)
Chuck Type:Push button
Workign Air Pressure:0.22-0.30MPa(0.25MPa prefrred)
Atomization Pressure:Under 5.00Mpa(0.30MPa prefrred)
Supply Voltage:3.2-3.5V
Free Load Speed:≥280,000R.P.M for torque head ≥350,000R.P.M for standard head
Life Of Led Bulb:≥5000hours
Led Luminous Intensity:≥1500mcd
Speed Of Generator:18,000-22,000R.P.M
Advantage
1. Fiber optic LED handpiece with self generator quick coupling,the
generator is inside the quick coupling,no need to autoclave under
135°C,would not damage;
2. The LED bulb can be changed easily,no need to ask for
professional maintainance,the densit can change easily by
theirselves;
3. Import LED bulb,professional LED light source,superior
brightness,more than 25000lux,
longevity 10000 hours.
4. 4 hole or 2 hole self generator quick coupling,can fit mainly
dental chair,no need fiber optic PCB board,easy to install and save
money;
5. Open cartridge,easy to clean and repair,work smoothly and
longer.
6. 135°C Autoclavable for 700 times.
7. 4 water spray and anti-retraction system to provide a fine spray
mist for better visibility,
cooling and cutting speed.
Product Parts:
Consists of handpiece head, handle, caudal thread, cartridge.
Working Conditions:
1.Air pressure 0.25~0.30mpa,must be filtrated.
2.Use high speed dental bur with shaft diameter
Φ1.59~1.60mm×21-23mm and roghtness less than 0.8um.
3.The amount of handpieces spray or water spray should be able to
adjusted.
4.Hard glass fiber,can be repeatedly sterilized in high temperautre
and pressure.
Product Scope:
Only used for drilling, molar of stomatology clamping high-speed
dental burs.
HPA013 Handpiecewe Provide Two Kind Of Head For Choice
HPA013S | HPA013T |
Standard Head | Torque Head |
Features:
1.Clamping force of handpiece is:20-45N
2.Noise not exceed 70dB
3.At 25-30 atmosphele pressure,350,000-400,000R.P.M(Standard
Head);280,000-320,000R.P.M(Torque Head)
Maintenance:
1.Considering safety first, please be careful to use it with full
attention.
2.Be limited to dentists who held the dental treatment
qualifications.
3.Strictly forbid decomposition and reconstruction by unauthorized.
4.Please run point testing on outside of patients oral beforehand.
If feel anomalies, please stop using immediately and contact with
our after-sales center.
5.When appears abnormal during using, please stop it immediately
and contact with our after-sales center.
6.It will cause a high noise using a center-vibration or bended bur
and a handpiece of which bearing has been worn, A long time in this
state will be harm to people’s hearing. Forbid using a vibration or
bended bur, if appear high noise, please replace the shaft core
early
7.Do not use a bending , cracking, deformation and unqualified bur.
If using it, may cause a snap, or a flying off to injury accident
during operation process.
8.Please ensure the bur chuck be clean. If with contaminant inside
of it, may causes bur clamping weaken or shaft core vibration.
9.Please run the bur under the provision rotation-speed by bur
manufacturers.
10.Do not crash, especially to avoid falling.
11.Please install a bur or a standard stick before using.
12.Aslo remember to install a bur or a standard stick when not in
using.
13.Please unload the bur and handpiece when the running stopped in
completely.