NINGBO TOPZHOU METERS INDUSTRIAL AND TRADING CO.,LTD |
|
Industrial Multi Jet Woltman Compound Water Meter with High Pressure
Description:
Combination Detachable Dry-dial Type Water Meter LXFY-80~150
Quick Detail:
1. Type name: Woltmann removable type
2. Model No.: LXFY-80 ~ 150
3. Standard :ISO 4064 Class B
4. Material: Cast iron
5. Large measuring scale and minimum starting flow rate
6. Horizontal installation
Product features:
Detachable ,liquid-sealed type ,rotary vane wheel type
Special liquid sealed register ensures the dial keep the reading clear in a long term service
Especially suitable to water supplying system of variable flow rate
Novel structure ,easy maintenance
Large measuring scale and minimum starting flow rate
Application:
This range of water meter is used to measure the total quantity of cold water which consumed in industrial and mining enterprise passing though the pipeline.
Installation requirements:
Main Technical data
Meter Size DN (mm) |
Class
| Qs Overload Flow | Qp Nominal Flow | Qt Transitional Flow | Qmin Min Flow | Starting Flow | Min Reading | Max Reading |
m³/h | L/h | m³ | ||||||
50 | B | 30 | 15 | 0.20 | 0.05 | 16 | 0.0001 | 9999999+99999 |
80 | B | 80 | 40 | 0.20 | 0.05 | 16 | 0.0001 | 9999999+99999 |
100 | B | 120 | 60 | 0.20 | 0.05 | 16 | 0.0001 | 9999999+99999 |
150 | B | 300 | 150 | 0.80 | 0.20 | 60 | 0.0001 | 9999999+99999 |
Meter size (mm) | Change-over flow | |
Qx1 (m³/h) Valve opening flow | Qx2 (m³/h) Valve opening flow | |
50 | 2.5 | 1.5 |
80 | 2.5 | 1.5 |
100 | 2.5 | 1.5 |
150 | 10.5 | 8 |
Maximum permissible error:
In the lower zone from Qmin inclusive up to but excluding Qt is ±5%
In the upper zone from Qt inclusive up to and including Qs is ±2%
Working Condition:
Water temperature:0℃≤t≤40℃ (For cold water meter)
Water pressure: ≤10bar (16bar on request)
Competitive Advantage:
Reasonable price with good quality
Long time guarantee
100% tested
On time delivery