Product Details

3 Phase 380V 37KW 50HP 75A MPPT Solar Pump Drive Inverter
 
ZK SU100 series MPPT solar pump inverter mainly features:

 

Built-in adaptive high-precision photovoltaic array MPPT algorithm, accuracy more than 99%

Input power can be solar DC and Grid AC

Effective waterless operation mode. If water pressure is low, reduces the frequency or stops by itself

Utmost water flow output, irrespective of the environment

LED displays the real-time system status and parameters

The soft-start of the motor avoids the water hammer effect and improves system service life

Built-in comprehensive protection and diagnosis mechanism

With overvoltage protection, overcurrent protection, over-temperature automatic frequency reduction and other protection functions; DC input anti-reverse function

Easy operation-Easy to install, no need to set parameters, ready to use, and has a one-key parameter recovery function

Ambient temperature for using: -10 to +55˚C.

 
How to select the solar panels for your solar pumping system?

 

Input voltage, power solar selection
Pumps modelInverte modelsVmpVocTotal Power of solar arrays
110VAC pumpT1 (for 110V)130VDC156VDC

≧ (1.3 to 2.0) rated power of Pump
It is also depend on the quality of solar panels. The higher the power input, performance will be better

220VAC pumpT2 (for 220V)310VDC372VDC
380VAC pumpT3 (for 380V)540VDC648VDC

 
Solar pump inverter MPPT efficiency more than 99%, but also
have to consider many factors of solar radiation. Like the quality of the solar panels. If the output frequency can’t get to 50Hz/60Hz, please try to add more solar panels, but voltage can not big than the inverter Max inout voltage.


Technical specifications:
 

ItemSpecification
Power inputVoltage, frequency

T1: 90V DC to 400V DC or 110V±15% AC, 50/60Hz
T2:150V DC to 450V DC or 220V±15% AC, 50/60Hz
T3: 250V DC to 750V DC or 380V±15% AC, 50/60Hz

 Allowable fluctuationsvoltage unbalance rate:<3%; Frequency:±5%; aberration rate: as IEC61800-2 required
 Power factor≥0.94(with DC reactor)
 Efficiency≥96%
OutputOutput voltageOutput under rated condition: 3 phase, 0~input voltage, inaccuracy<5%
 Output frequency range0-50/60HZ. (0-600HZ for PMSM)
 Output frequency accuracyMax frequency ±0.5%
 Overload capacityG type: 150% rated current/1 min, 180% rated current/10s, 200% rated current/0.5s
Main control performanceMotor control modeV/F without PG , VC without PG , VC with PG
 Speed control rangeVector control without PG, rated load 1:100;Vector control with PG, rated load 1:1000;
 Steady speed accuracy

VC without PG: ≤2% rated synchronized speed;
VC with PG: ≤0.05% rated synchronized speed

 Starting torque

VC without PG: when 0.5Hz, 150% rated torque;
VC with PG: when 0Hz, 200% rated torque

 Torque response

VC without PG: ≤20ms;
VC with PG: ≤10ms.

 Frequency accuracy

Digit setting: max frequency×±0.01%;
Analog setting: max frequency×±0.2%

 Frequency resolution

Digital setting: 0.01Hz;
Analog setting: maximum frequency × 0.05%

Product
basic functions

DC braking capacity

Starting frequency:0.00~50.00Hz; Braking time:0.0~60.0s;
Braking current:0.0~150.0% rated current

 Torque boost capacity

Auto torque upgrade 0.0%~100.0%;
Manual torque upgrade 0.0%~30.0%

 V/F curve4 modes: one linearity torque characteristic curve ,one self-setting V/F curve mode, one drop torque characteristic curve (1.1- 2.0 powers),and square V/F curve mode.
 Acceleration/Deceleration curve

2 modes: linear Acceleration/Deceleration and S curve Acceleration/Deceleration.
4 sets of ACC/DEC, time unit 0.01s selectable, longest time: 650.00s.

 Rated output voltageRely on power supply voltage compensate function, while motor rated voltage is 100%, set it at the range of 50-100%(output can not over input voltage).
 Voltage auto-adjustmentWhile power supply voltage fluctuates, it can auto-keep constant output voltage.
 Auto energy-saving runningWhile under V/F control mode, according to load situation, auto-optimize output voltage to save energy.
 Standard functionsPID control, speed track, power off restart, jump frequency, upper/lower frequency limit control, program operation, multi- speed, RS485, analog output, frequency impulse output.
 Frequency setting channelsKeyboard digital setting, keyboard potentiometer ,Analog voltage/current terminal AI1,AI2, Communication given and multi-channel terminal selection, Main and auxiliary channel combination, expansion card, supporting different modes switch.
 Feedback input channel

Voltage/Current Terminal AI1, Voltage/Current Terminal AI12, Communication
given, pulse input X5.

 Running command channelOperation panel given,external terminal given, communication given, expansion card given.
 Input command signalStart, stop, FWD/REV, JOG, multi-step speed, reset, ACC/DEC time selection, frequency given channel selection, exterior fault alarm.
Protective functionOvervoltage, under-voltage, current limit, over-current, overload, electric thermal relay, overheat, overvoltage stall, data protection, rapid speed protection, input/output phase failure protection.
EnvironmentInstall placealtitude ≤ 1000m,above 1000m down the rated amount, each increase of 100m down the rated mount of 1%;no condensation, ice ,rain, snow, hail; solar radiation below 700W/㎡, air pressure 70-106 kPa.
 Temperature, humidity-10 ~ + 50 ℃, derating above 40 ℃, maximum temperature 60 ℃ (no-load operation)5% to 95% RH (non-condensing)
 VibrationWhen 9~200Hz, 5.9m/s2(0.6g)
 Storage temperature-30 ~+50℃
 Protection gradeIP20, (IP54 is avaliable)
 Cooling methodForced air cooling
 

Model number list and specifications:
 

D1: General type:90V DC to 400V DC or

110V±15% AC, 50/60Hz

D2: General type:150V DC to 450V DC or

220V±15% AC, 50/60Hz

Inverter

specification

Current (A)

 

Inverter

specification

Current (A)

 

SU100-D1-R75G-B7SU100-D2-R75G-B4
SU100-D1-1R5G-B10SU100-D2-1R5G-B7
 SU100-D2-2R2G-B10
 SU100-D2-004G-B16

D3: General type:250V DC to 750V DC or

380V±15% AC, 50/60Hz

T3: General type:350V DC to 750V DC or

380V±15% AC, 50/60Hz

Inverter

specification

Current (A)

 

Inverter

specification

Current (A)

 

SU100-D3-R75G-B3SU100-D3-037G75
SU100-D3-1R5G-B4SU100-D3-045G90
SU100-D3-2R2G-B6SU100-D3-055G110
SU100-D3-004G-B10SU100-D3-075G150
SU100-D3-5R5G-B13SU100-D3-090G180
SU100-D3-7R5G-B17SU100-D3-110G210
SU100-D3-011G-B25SU100-D3-132G250
SU100-D3-015G-B32SU100-D3-160G310
SU100-D3-018G-B38*** 
SU100-D3-022G-B45  
SU100-D3-030G60  


 
 

 

Hot Products

0.75KW To 22KW Three Phase SG320 Series Solar Vfd Solar Pump Inverter For Solar Pumping System ZK ...
solar controller inverter system Solar pump inverter obtains direct current energy from photovoltaic ...
3 Phase 380V 37KW 50HP 75A MPPT Solar Pump Drive Inverter ZK SU100 series MPPT solar pump inverter ...
Solar water mppt vfd pump inverter drive 7.5kw 380v 440v Descriptions and Features: Whenever ...
IP54 Solar pump inverter MPPT for PMSM and AC PUMP Main feature of solar pump inverter: 1. IP65 ...
22KW IP54 waterproof Solar Pump Inverter solar pumping system consists of 3 components: 1.Solar ...