TLU Technology Co., LTD |
|
Honeywell TDC 3000 PLC Module 51195155-100 Original Brand New
C300 Controller Device Index
The Device Index, in conjunction with the Base IP Address (entered in the System Preferences dialog of Control Builder), gives the controller a unique IP address on the FTE network where the controller resides. The Device Index is manually set by using the three rotary switches located on the controller IOTA. The Device Index is also entered on the controller block configuration form (DEVICEIDX parameter).
Upon power-up of the controller, the Device Index is provided to the BOOTP Server on the associated FTE community. The BOOTP server issues an IP address for the controller, based on the Device Index of the controller and the Base IP Address configured for the FTE community. The controller's IP address identifies the controller as an FTE node on the network.
Advantage products
Allen Bradley | Bently Nevada | ABB | ICS Triplex | GE FANUC |
1756-IM16I | 3500/32 | CI810B | T8312 | IC693PWR321Y |
1756-OW16I | 3500/42M | CI854AK01 | T3481 | IC693CHS397L |
1749-IE12 | 3500/20 | IMMFP12 | T3511 | IC697ALG230F |
1794-OE12 | 3500/50 | IMDSM04 | T3310 | IC697MDL653 |
1747-L531 | 3500/15 | IMFCS01 | T3401 | IC200ALG322D |
1756-DNB | 3500/25 | NTAI06 | T3420A | IC200ALG320B |
1756-OF8 | 3500/92 | NTCL01 | T3401 | IC200ALG260A |
1746-NI16I | 128229-01 | INNIS21 | T3481 | IC200MDD843E |
1746-IB16 | 125720-01 | BRC300 | T3310 | D20EME 526-2100 |
1746-IB32 | 125760-01 | SCAAE35510 | T8225 | IS215WEPAH2BB |
1746-OW16 | 133442-01 | IMASI23 | T8151B | IS210BPPCH1AD |
1747-L532 | 125840-01 | TPS02 | T9432 | IS200AEPAH1BKE |
1747-L531 | 133396-01 | 3BHB002953R0108 | T9110 | IS220PSVOHIA |
1756-IF16 | 125800-01 | 6640635A1 | T9402 | IS220PAICH1A |
1747-L541 | 133323-01 | NTCL01-A | T9451 | IS220PDIOH1A |
1756-OF8 | 135137-01 | NTD101 | T9802 | IS220PPROH1A |
1785-KA | 125768-01 | SPDS014 | T9852 | IS220PPDAH1A |
2711-T10C15 | 330130-040-00-00 | SPAS011 | T9300 | IS200TBAIH1C |
2711-T10C20 | 330100-90-01 | SPNIS21 | T9100 | IS230TBAIH2C |
1756-CNBR | 330100-90-00 | SPDSI14 | T9832 | IS200STAIH2A |
1747-L541 | 24583-04 | SPNPM22 | T8403 | IS2305TAIH2A |
1757-SRM | TK3-2E | SPFEC12 | T8311 | IS220PMBH1A |
2711-NC13 | 135489-01 | IMASO11 | T8403 | IS200TVBAH2A |
1756-EN2T | 140471-01 | SPBRC300 | T8440B | IS230TVBAH4A |
1746-NI4 | 3500/15 | INNPM12 | T8193 | IS220PTCCH1A |
1756-BA2 | 330130-040-01-00 | IMHSS03 | T8311 | IS200STTCH2A |
1771-IMD/B | 330130-045-01-00 | NTAI05 | T8442 | IS230STTCH2A |
1771-OBD/C | 330130-040-01-05 | NTDI21-A | T8151B | IS200STCIH6A |
1771-P6R C | 330130-080-00-00 | NTHS03 | T8130 | IS230STCIH6A |
1771-P6S B | 330130-00-07-10-02-00 | NTR012-A | T8431 | IS220PRTDHIA |
1785-BCM/C | 330130-080-00-05 | NTCLO1-A | T8403 | IS200SRTDH2A |
1785-L20B | 330130-040-00-00 | P-HC-BRC300 | T8461 | IS230SRTDH2A |
1771-OFE2 | 330130-045-00-05 | 3DDE300402 CMA120 | T8480 | IS200TRLYH1B |
1771-IR | 3500-42M | 3DDE300402 CMA122 | T8191 | IS230TRLYH1B |
2711P-B10C15A1 | 3500/25 149369-01 | DAPU100 3ASC25H204 | T8220 | IC694MDL645 |
Contact Me
Email: sales7@cambia.cn (Skype)
Tel:+86 18030273592(Whatsapp/Wechat)
skype id:sales7_1232
TIMED TWO-POSITION CONTROL
GENERAL
The ideal method of controlling the temperature in a space is to replace lost heat or displace gained heat in exactly the amount needed. With basic two-position control, such exact operation is impossible because the heating or cooling system is either full on or full off and the delivery at any specific instant is either too much or too little. Timed two-position control, however, anticipates requirements and delivers measured quantities of heating or cooling on a percentage on-time basis to reduce control point fluctuations. The timing is accomplished by a heat anticipator in electric controls and by a timer in electronic and digital controls. In timed two-position control, the basic interaction between the controller and the final control element is the same as for basic two-position control. However, the controller responds to gradual changes in the average value of the controlled variable rather than to cyclical fluctuations.
Main Brand
Invensys( 4329, 3805E, 3503E,3721,3636T,DO3401,3625)
GE Fanuc(IS200VVIBH1CAB DS200LDCCH1AGA IS220PAICH2A IC200MDL640K)
Yokogawa(CP451-10,SSB401-13,PW482-10,SB401-10,MX3*D,ST2*D)
Siemens( 6ES7332-5HD01-0AB0, 6ES7414-4HJ04-0AB0,
6ES7417-4HT14-0AB0)
Foxboro ( FBM205, FBM211, FBM202, FBM217, FCM10E, P0971WV, FBMSVH)
Allen-Bradley ( 1746-IB32, 1747-L533, 1756-ENBT, 1756-L61,
1769-OF4, 1771-IBN, 1785-L40B )
Bently Nevada ( 3500/94, 3500/53, 3500/22M, 3500/42M, 330180-90-00
)
Honeywell ( TK-PRS021, TC-FPDXX2, CC-TCNT01, 8C-PAIH51,
51309355-001, 10006/2/1 )
ABB ( 07KT97 WT97, AI835, CI854AK01, DSQC639, DO810, PM861AK01,
SNAT603 )
Triconex ( 3625, 3503E, 3008, TCM 4353, 4351B, 4409)
ICS Triplex ( T8310, T8431, T8461, T8451, T8110B, T8403, T3481)