Home Companies Zhejiang Shengdi Technology Inc.

HS-3303 Three Phase Energy Meter Test Equipment with 3 Position Meter Rack,internal Reference Meter 0.05% Class

Zhejiang Shengdi Technology Inc.
Active Member

Contact Us

[China] country

Address: #8,Zhenghua Road,Wuyuan Industry Zone,Haiyan County

Contact name:Yeli Lu

Inquir Now

Zhejiang Shengdi Technology Inc.

HS-3303 Three Phase Energy Meter Test Equipment with 3 Position Meter Rack,internal Reference Meter 0.05% Class

Country/Region china
Categories Other Electric Power Tools
InquireNow

Product Details

  • HS-3303 Three Phase Portable Energy Meter Test Bench


  • Portable Three-phase electrical meter test set,5mA~120A,100VA output capacity,1~3 Places

  • HS-3303 serial products are small-sized, light-weight three-phase equipment; they adopt SPWM power amplifier technology, equip with high accuracy digital reference standard meter, MSPT etc., to operate high precise energy error calibration.

    HS-3303 serial products also equip with PC control software and offer whole solution scheme for energy meter automatic calibration, also can supply DLL for second research; greatly improve user’s control and manager ability to equipment.

     

    Portable Three-phase electrical meter test set,5mA~120A,100VA output capacity,1~3 Places

  •  

  • 1.Based on A/D and DSP technology

  • 2.Use DDS and SPWM technology
  • 3.Equip with smart system control technology and CPU
  • 4.Precise error processing technology
  • 5.SPWM power amplifier, huge content, high performance, and low consumption, automatic alarm
  • 6.Each station has an error processor, anti-high electric power
  • 7.Modules design, easy to install and debug Automatically finish testing according to scheme through one-click
  • 8.Aluminum frame, beautiful and strong
  • 9.Customized according to the customers’ requirements
  • 10.Small-sized, light-weight, and big output power
  • 11.Flexible operation, can control each output factor fast
  •  

    Portable Three-phase electrical meter test set,5mA~120A,100VA output capacity,1~3 Places

  •  

  • Technical Parameters

    Item0.050.1
    Accuracy

    HS-5300 0.05/

    TC-3000D 0.05(embedded)

    HS-5300 0.1/

    TC-3000D 0.1(embedded)

    Rangevoltage(phase):20~300V(40-600V optional) current(phase):5mA~120A
    Phase0~360°,resolution:0.01°(each phase can adjust separately)
    F45~65Hz, resolution:0.01Hz
    THDvoltage,current<0.5%(linear load)
    Power stability

    <0.05%/120 s

    <0.1%/120 s

    Output content

    voltage(each phase):50VA current(each phase):100VA(100A)

    Load characteristicresistive,inductive,capacitive(less than 1uF/each station)
    Starting up currentMin. 2mA, accuracy:5%, starting up power: accuracy 5%
    Pulse input≤1kHz
    COM. testRS485/232/ IR/ carrier, support DL/T645-1997/2007,IEC1107
    Tested meter1~3
    Working conditionsTemp.:20℃±5℃; Humidity:<85% R.H.
    Input power

    AC220±10%,50/60Hz,(AC120V optional);Max. consumption:500VA

     

    Model

    ModelNameApplication
    HS-3303three-phase energy meter portable equipmentcommissioning,maintenance,development
    HS-3303Bthree-phase energy meter movable equipmentdevelopment,calibration

     

    Functions

    Item

    HS-3303

    HS-3303B

    Basic functionsbasic error
    creeping test
    starting up test
    standard deviation
    constants test
    dial error
    influence test
    othersdaily timing error ☆ 
    GPS ☆ 
    COM. test ☆ 

 

SAMPLE 

 

Technical Specification
1. The device IS according to IEC 62053-11 IEC 62053-21 IEC 62053-22 IEC 62053-23
2. Testing of three phase Open-link meters(3 Positions) or 3-phase Close-link Meter(1 Position).
3. The device IS able to test meters with connection 3P4W and 3P3W.
4.  With Movable type meter hanging rack(3 Positons).
5. The device IS able to test meters with voltage range from (20-300) V and current range up
to 120 A.
6. The device HAS screen display to display the needed information.
7. The devise HAS PC software to run the tests with report generator to print the results
needed. 
8. All of the tests IS saved on the PC with the ability to retrieve any test based on the serial number of
meter at any time.

9.Test function: basic error,start test,creep test,warm-up test,standard deviation,constant test,etc.

 

Ask for price: hysdsales@gmail.com

 

         

SUIT FOR TESTING THREE-PHASE KWH METER

 

 

 

 

Portable Three-phase electrical meter test set,5mA~120A,100VA output capacity,1~3 Places

Hot Products

HS-3303 Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...
HS 3303 Three Phase Portable Energy Meter Test Equipment (For testing whole current 3 phase meter ...
HS-3303 Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...
HS-3303 Three Phase Portable Energy Meter Test Bench (Moveable rack,3 Position,Internal Reference ...
HS6103 Single Phase Electricity Meter Test Bench HS-6103 single-phase energy meter testing bench ...
HS6103 Single Phase Electricity Meter Test Bench (1P2W electricity revenue meter test bench,0.05% ...