HS-3163P Portable single-phase test system is a high-performance calibrating instrument which is designed with international new digital technology. This test system consists of an integrated single-phase wide range voltage & current source and a single-phase electronic reference standard meter of accuracy class 0.05%. It is wide measuring range, 0.05% class high accuracy ,high tolerance to unwanted external influences and more utility functions.

HS-3163P is mainly used on-site to test energy meter’s installation,running and analyze power system.

Main technical features

  • Internal small single-phase current source which synchronized with on-site voltage;
  • Outputs 0-16A current, meets user’s multiple model, multi-load point check.
  • Can connect with current clamps, uses to on-site online calibration;
  • Adopted ARM 32-bits core embedded system, and with 7 inch TFT LCD TOUCHED SCREEN;
  • HMI design, full screen touched operation, can continue to calibrate automatically according to the scheme;
  • Can save test data for 1000 energy meters;
  • Can be used as a reference standard meter or single-phase calibration device;
  • Small size, low weight, low consumption, high accuracy and portable;
  • Support Bluetooth, and can be controlled by APP (on phone or PC);
  • With self-protection, sound and light alarm functions when current overload.

Main measurement functions

  • Independent generation of single-phase current loading conditions for verification of meters using the incoming supply voltage or internal independent generation of single phase voltage.
  • Active,reactive and apparent energy measurement with integrated error calculator and pulse output;Or with 3D and adjustable scanning head (Optional).
  • Automatically test creeping error,starting-up error,basic error and standard deviation error etc.;
  • Support energy constants verification or dial testing;
  • Support daily timing error testing;
  • Support current harmonic influence value testing;
  • When calibration, user can choose testing points freely, also can make calibration scheme freely;
  • Testing data can be saved in instrument and inquiry, and allow data import& export;
  • Can display vector diagram, harmonic spectrum and wave form to analyze power system;
  • Measure voltage, current directly or by current clamps;
  • Measureactive,reactive power and apparent power;
  • Measure phase angle,PF and frequency;

Application Range

  • Calibrate different types of energy meters before they are installed on-site;
  • Analyze energy meter running condition and error data;
  • Used for R&D and maintenance test;
  • Test and monitor power system.

2,General Technical Index

Auxiliary power supply198 VAC … 253 VAC / 47 … 63 Hz
Power consumption200 VA
ShellHard plastic
Dimension355 x 272 x 166 mm(W*H*D)
Weight≤7KGS( not including spare parts)
Working Temp.-10 °C +50 °C
Storage Temp.-20 °C … +60 °C
R.H.≤85%,≤21°C

3,Voltage source technical standard

Output voltage range/power20 V … 300 V / 20 VA
Resolution0.001 V
THD≤ 0.5%
Stability≤ 0.05% (3 min.)
Adjust range0% … 120%(240V)
Frequencyrangeaccuracyresolution
45 Hz – 65 Hz±0.01 Hz0.01 Hz

4,Current source technical standard

Output current range/power5 mA … 60 A / 50 VA

 

Current output(Terminal)

currentrangeSmax / Umax
0.1 A5 mA … 100 mA0.6 VA / 6 V
1 A0.1 A … 1 A5 VA / 5 V
10 A1 A … 10 A12 VA / 1.2 V
50 A10 A … 50 A50 VA / 1 V
Resolution0.01%*range
THD≤ 1%
Stability≤ 0.05% (3 min.)
Adjust range0% … 120%
Phase anglerangeaccuracyresolution
0°…359.99°0.2°0.1°
Frequency

 

 

rangeaccuracyresolution
45 Hz – 65 Hz±0.01 Hz0.01 Hz
      

5,Reference standard meter technical standard

5.1,Measurement range

Measurementrangeinput/ sensor
Voltage10 V … 300 VU
Current5 mA … 60 AI
10 mA … 120 Aclamp 20A,100A

5.2,Voltage and current measurement accuracy

voltage / current≤±E[%]1 2
Measurementrangeclass
Voltage100 V … 300 V

 

10 V … 100 V

0.05

 

0.2

Current20 mA … 60 A

 

5 mA … 20 mA

0.05

 

0.2

Clamp10% ≤ RG ≤ 120%

 

1% ≤ RG < 10%

0.2

 

0.5


5.3,Energy measurement accuracy

Power/energy voltage:100 V … 300 V≤±E[%]1 2 3
Measurement /output currentrangeclass
Active power(P),apparent power(S)
Output20 mA … 60 A

 

5 mA … 20 mA

0.05

 

0.2

Clamp10% ≤ RG ≤ 120%

 

1% ≤ RG < 10%

0.2

 

1.0

Reactive power(Q)
Output20 mA … 60 A

 

5 mA … 20 mA

0.1

 

0.2

Clamp10% ≤ RG ≤ 120%

 

1% ≤ RG < 10%

0.4

 

1.0

Magnetic influence:≤0.07 % / 0.5 mT³(45 Hz … 66 Hz);

Temp. coefficient(TC):
range≤ ±TC[%/℃] 3
0 … +40 0.02
-10 … +50 0.05

 

5.4,Frequency,phase,PF measurement accuracy

F/Phase angle/PF≤ ±E
Measurementrange 
F45 HZ … 65 Hz0.01 Hz
θ0.00° … 359.99°0.1°
PF-1.000 … +1.0000.002

remarks:

  1. x.x: Related to measurement value

x.x: Related to measurement range(Max range,FS),E(M)=FS/M*x.x( for example: 0.2, FS =46 v, E(10V) = 46/10 * 0.2 = 0.92 %)

  1. Basic frequency range: 45 … 65 Hz
  2. S:x.x,P,Q:x.x/ PF

 

5.5,Pulse input/output

Input TTL3 … 6 VDC
Input FMax.200 kHz
Output TTL5 VDC
Pulse width≥ 10μs
Constants:

 

Active power,reactive,apparent power

[imp/kWh(kvarh,kVAh)]

C = 1×109/In’;In’= In×(100%,50%,25%)

 

Constants depends on internal ranges(In)

Details see constants table

 Current In[A]
Measurement0.111050
100%In50%In25%In
Output FC’= C/3600000[imp/Ws(vars,Vas)]

 

fo = C’×P∑(Q∑,S∑)

fmax = 16.666kHz

       

6,Others

Position1
COM. portRS232,Bluetooth
Energy error indication range-99.999%~+2000.0%
Other functionsVictor diagram display,error display,harmonic analysis display

 

 

Hot Products

HS-3163P Portable single-phase test system is a high-performance calibrating instrument which is ...
HS-3103 Portable Single Phase Energy Meter Test Bench HS-3103 serial products are small-sized, light...
HS-3303B Three Phase Portable Energy Meter Test Bench Overview HS-3303 serial products are small...
HS3303 Three Phase Portable Energy Meter Test Bench 1.Inserted with Poly-phase Standard Energy Meter...
HS-3303B Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...
HS-3303B Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...