DM-2510T Dust Particle Counter Measurement Meter

Country/Region china
City & Province suzhou jiangsu
Categories Measuring & Analysing Instrument Design Services
InquireNow

Product Details

 

MAS-I Micro Air Station

 

Description

 

DM-2510T online dust meter is suitable for rapid determination of the concentration of respirable particulate matter in the atmospheric environment, detection of dust concentration in labor hygiene aspects such as production sites of industrial and mining enterprises, and monitoring of respirable dust concentration in the field of environmental protection.

 

This product adopts a special optical cavity design and introduces sheath gas to protect the entire optical cavity, thereby reducing the contamination of the optical cavity by dust particles to a great extent and reducing the maintenance workload.
The product design complies with the JJG846-2015 standard and has been widely used in real-time monitoring of dust concentration in public places such as construction sites, industrial and mining enterprises, storage yards and docks. It can more quickly and directly observe the continuous changes in atmospheric dust concentration, which is in line with relevant industry standards. Laws, regulations and standards can also effectively improve work efficiency and can be applied both indoors and outdoors.

 

Feature

 
Accuracy parameters
/PRECISION PARAMETER
Optical particle size cutting, can monitor PM1.0, PM2.5, PM10.0, TSP simultaneously
Long life
/LONG LIFE
Add sheath gas protection function to extend the service life of the equipment itself
Built-in protection
/BUILT-IN PROTECTION
Increase the protection function of the air path
self feedback
/SELF-FEEDBACK
Increased flow feedback realizes constant flow control, maintains the stability of sampling volume, and improves accuracy.
Easy maintenance
/ EASY MAINTENANCE
Easy to install and disassemble
Data is accurate
/ACCURATE DATA
Zero calibration and span calibration can be achieved through software
Sampling is controllable
/ SAMPLING CONTROLLABLE
Customizable sampling method and controllable sampling time
Data is accurate
/ACCURATE DATA
Add mass concentration conversion coefficient
Multiple output
/MULTIPLE OUTPUT
Interface output, RS232/485, etc.​

 

 

Specification

 

 

Monitoring ParametersPm1.0, Pm2.5, Pm10, Tsp
Concentration Range0-30(Mg/M³)
Monitoring Accuracy0.1(μG/M³)
The Sampling PeriodSampling 15 Seconds, Interval 45 Seconds
Usage EnvironmentAtmosphere
Communication MethodRs232, Rs485
Power SupplyDc: 12-24v
Power Consumption4.0w
Dimensions215×70×160mm3
Quality1.3kg
Installation MethodSmart Wall Mounting

 

 

Function and definition
Sampling port: Please remove the protective cover of the sampling port before using the product.

Exhaust port: Do not close the exhaust port during use.

External filter:

When replacing the external filter, please pay attention to the direction of the arrow and do not allow reverse access to the air path.

Terminal wiring definition:

The wiring terminals (as shown in the picture above) are numbered 1-8 from left to right.

The wiring definition of input and communication is as shown in the following table:

 

12345678
(+)(-)ABgroundTXDRXDGND
Input terminal (DC: 12V)RS485RS232

 

MODBUS-RTU protocol description
Brief description of the agreement
Byte transmission method

lBaud rate: 9600

l1 starting bits

l8 data bits

lNo parity bit

lError checking (Error Checking) CRC (cyclic redundancy check, low byte first then high byte)

Protocol data frame format

 

AddressFunctionDataCheck
8-Bits8-BitsN×8-BitsCRC-LoCRC-Hi

 

Address field

Only 1-247 is used in the meter, other addresses are reserved. FCH is the broadcast address.

Function domain

 

codesignificancecommunication methodeffect
03HRead data registerCharacterGet the current value of one or more registers
06HSet a single register valueCharacterSet a value to a register

 

 

Error checking methods

The process of generating a CRC is:

l Pre-prepare a 16-bit register bit FFFFH (all 1), called CRC register;

l Perform an XOR operation on the 8-bit bytes in the data frame and the low byte in the CRC register, and store the result in the CRC register;

l Shift the CRC register one bit to the right, fill the bit with 0, and move the lower limit bit out and detect it;

lIf the lower limit is 0: repeat step 3 (next shift);

lIf the lower limit is 1:

XOR the CRC register with a preset fixed value (A001H);

Repeat the third and fourth steps until 8 shifts, so that a complete eight bits are processed;

Repeat steps 2 to 5 to process the next eight bits until all bytes are processed;

The value of the CRC register is the value of the CRC.

There is also a method of calculating CRC using a preset table. Its main feature is fast calculation speed, but the table requires a large storage space. I will not go into details here. Please refer to the relevant information.

Detailed explanation of communication format

Read data (function code 03)

The obtained data is converted into actual values according to the corresponding data item type.

Command example: read PM2.5 data, address 01H, read length is limited, word mode

send:Instrument addresscommand codeStarting address codeRead length [word unit]CRC16
 130802CRC-LoCRC-Hi
Correctly returns:Instrument addresscommand codeByte lengthnumerical valuecheck
 134xx xx xx xxCRC-LoCRC-Hi

Set a single register (function code 06)

Function code 06H allows the user to change the contents of a single register

Command example: Set the instrument working period to 15 seconds, address 01H

Parameter address list

 

 

addressparameterRead and write propertiesNumeric rangetype of data
6/40006TSP (1 decimal place) period dataR0~999999999DWord
8/40008PM2.5 (1 decimal place) period dataR0~999999999DWord
10/40010PM10 (1 decimal place) period dataR0~999999999DWord
33/40033Running status (write "0" to stop)R/W0~1Word
38/40038Number of measurementsR/W0~255Word
39/40039IntervalsR/W0~255Word
40/40040Delay timeR/W0~255Word
41/40041Sampling cycle timeR/W1~65535Word
60/40060Local addressR/W1~247Word

 

 

illustrate:

lData type: "Word" refers to a 16-bit unsigned integer;

"DWord" refers to a 32-bit unsigned integer.

l Read and write attributes: "R" is read-only, "R/W" is readable and writable, and it is prohibited to write data to addresses that are not listed or do not have writable attributes;

lThe dust concentration is a 32-bit unsigned integer. The high and low bits each occupy an address, with the low bit in front and the high bit in the back. Multiply the high-digit value by 65536 and add the low-digit value to obtain the parameter value, and then divide by 10 to obtain the actual value of the parameter (unit: μg/m³).

lIn order to simplify the user's operating instructions, you can use the 03H instruction to read the PM parameter address, and the instrument will automatically start, eliminating the need to send instructions to write instrument status, making it convenient for users to operate the equipment.

safety regulations
Precautions:
To ensure the reliable use of the equipment and the safety of personnel, please comply with the following matters during installation, use and maintenance:
lWhen installing the equipment, make sure that the ground wire in the power cord is well grounded, and ensure that the input power of the equipment is DC 12V;

lDo not place system equipment in a place that is too cold or too hot;

lThe power supply of the equipment will generate heat when working, so the working environment must be well ventilated to avoid excessive temperature and damage to the machine;

l In rainy and humid weather or when not in use for a long time, the main power switch of the equipment should be turned off;

lNon-technical personnel should not attempt to disassemble the equipment without permission, and do not repair it without permission to avoid accidents or aggravated equipment damage.

other
Safe transportation: It should be stored in a ventilated, dry and harmful gas-free warehouse, and should not be stored together with chemicals, acid and alkali substances, etc.

Safe unpacking: After receiving the goods, please carefully unpack the outer packaging and handle it with care to avoid damage to the equipment inside due to collision.

lAfter unpacking, please check whether the items in the box are complete. Please refer to the packing list.

 

Maintenance instructions

DM-2510T online dust meter is a carefully designed and manufactured product. A good usage environment is conducive to the maintenance of the instrument and prolongs its service life.

Keep it dry and clean. Excessive humidity and dust will corrode the circuit board and shorten the life of the sensor;

It is prohibited to knock, vibrate or drop this product to avoid damaging the circuit board;

It is forbidden to use rough chemicals, detergents, and decontamination agents to clean the instrument. If there is dirt on the surface, you need to wipe it clean with a lint-free cloth dipped in 75% alcohol while the power is off;

If the instrument does not work properly, untrained personnel are prohibited from opening the host. Please cut off the power immediately and send it to a designated authorized service point or call after-sales service, and untrained personnel will provide you with assistance.

In order to ensure the safety and reliability of the instrument, it is recommended to calibrate it once a year. The user can return the instrument to the production unit for calibration, or follow the method provided by the manufacturer to perform calibration at a measuring station that complies with industry regulations.

 

After-sales service
DM-2510T online dust meter is an instrument carefully developed by our company for dust detection and monitoring. The company hereby promises that the instrument has a one-year warranty and lifelong maintenance.

Serve attentively and sincerely to you and me. Adhering to the principle of putting customers first and service first, our company will respond and answer customers' requests and questions one by one. Our company always pays attention to the cutting-edge technology in the industry, always considers customer needs and is committed to solving user solutions. While adhering to mature product quality, we timely launch various products and solutions suitable for customers.

Create a new model for the development of future purification products and provide customers with smarter, safer and more secure purification products. I believe that while our people are focusing on the future, they will also be based on the present, continue to track world technology, actively expand the application fields of new technologies, and continuously introduce solutions tailored for users.

If you have any questions, you can contact us at any time.

ØProduct maintenance

ØCalibration of products

ØProduct installation and testing

ØProduct verification and provide verification documents

ØProduct technical support

ØSales of product consumables

ØProduct delivery for inspection (measurement institute)

 

Schedule

The new air quality standards of the PM2.5 monitoring network, the 24-hour average standard value distribution is as follows:

 

 

air quality level24-hour PM2.5 average standard value
excellent0~35ug/m3
good35~75ug/m3
light pollution75~115ug/m3
Moderately polluted115~150ug/m3
heavy pollution150~250ug/m3
serious pollutionGreater than 250ug/m3

 

Packing & Delivery
Insertion type thermal gas mass flow meter RS-485,Modbus,RTU 1

FAQ
1. Q: What information need to be provided to choose the suitable model?
A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70% balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.

Hot Products

Description The MAS-I micro air station is a high-precision online air particle monitoring station ...
MAS-I Micro Air Station Description The MAS-H portable micro air station is suitable for rapid ...
MAS-I Micro Air Station Description Suzhou Better Intelligent MAS-I Dust Noise Online Monitoring ...
MAS-I Micro Air Station Description DM-2510T online dust meter is suitable for rapid determination ...
MAS-I Micro Air Station Description Suzhou Better Intelligent DM-S dust sampling head is an ...
MAS-I Micro Air Station Description V8100/TVOC volatile organic compounds (TVOC) online alarm ...