Flow Master MFE-S type High protection electromagnetic flowmeter | | | |
split type | One type (IP67) | Explosion proof integrated type |
Basic error | ± 0.2% or ± 0.5% of the indicated value | |
caliber (mm) | DN2.5~DN2400 | DN2.5~DN2400 |
Explosion proof grade | ------------ | Exia/de Ⅱ CT4 Ga/Gb |
flange | Comply with gb9119 standard, carbon steel (optional stainless
steel) |
Pressure class | DN2.5~DN600 1.0 1.6 2.5 4.0MPa DN700~DN2400 0.6MPa The special pressure shall be determined through consultation with
the company | DN2.5~DN600 1.0 1.6 2.5 4.0MPa The special pressure shall be determined through consultation with
the company |
Lining material | PTFE polytetrafluoroethylene, polyurethane rubber, PFA, F46,
natural rubber, neoprene, ETFE |
conductivity | ≥5μS/CM(Less than ≥ 5 μ S / cm negotiates the order with our
company ) |
electrode | 316L, Hastelloy, titanium, tantalum, platinum iridium alloy,
tungsten carbide |
Degree of protection | IP67(Sensor optional IP68) | IP67 |
Medium temperature | -25℃~140℃ See lining material selection for details | -25℃~80℃ See lining material selection for details |
ambient temperature | -25℃~60℃ |
Influence of ambient temperature | <±0.1%/10℃or<±0.25%/10℃ |
Repeatability and repeatability | ≤±0.1%or±0.25% |
Analog output error | ≤±0.02mA |
Measuring range flow rate | ≤20m/s |
Embedability | ≤5m(Only IP68) | ----------- |
Sensor cable | <100m If it is too long, you need to negotiate with our company to order | ----------- |
Electrical connection | M20*1.5Sealing sleeve,G1/2,NPT1/2 |
Output interface* | Standard output (pulse + 4 ~ 20mA single current output), dual
current output, RS485,HART,Profibus-PA |