Shenzhen Merrytek Technology Co., Ltd. |
Verified Suppliers
|
|
1. Product Feature
1) Built-in LifeBeing motion sensor and daylight sensor.
2) It can accurately detect and distinguish motion, minor motion,
breathing signals and illumination changes to interact with
different lights, air conditioners, background music, etc.
3) Based on 2.4G ZigBee protocol, can connect with various Tuya
smart devices, and controlled by Tuya App.
4) 120-277Vac input.
5) Effectively resist 5G, Wi-Fi, Bluetooth and other wireless
signal interference due to the patented low-impedance antenna
design.
2. Product Function
The product adopts a mechanism to report human body status
information (unmanned/occupied: walk mode, leisure mode, presence
mode) and the light level in every 30 seconds through the MCU
serial port.
Walk Mode: a large movement (walking) of the human body is detected within
30S.
Leisure Mode: only small motion of the human body are detected within 30S, such
as: forward, backward, limb swing, head shaking, typing, playing
with mobile phones and other minor actions.
Presence Mode: only detects human breathing within 30S (abdominal cavity,
thoracic cavity expansion behavior actions), no significant
movement is detected.
Light Level Report: report the current light level when the light level changes exceed
the preset value.
1) Sensitivity, indicator light, and hold time function are set
through the Tuya APP.
2) The motion sensor doesn’t work when the sensitivity is set to
0%.
3) Human occupancy detecting and daylight sensing supported, can be
associated with other equipment for automation.
4) Motion, minor movement, and breathing signals are all detected
to realize different behavior control mode.
5) Triggered status display (unmanned / occupied:walk mode, leisure
mode, presence mode).
3. Initialization
The Initialization will be finished after indicator light flashes
for 20 seconds when the initial power-on. During the initialization
period, the external movement signal is not detected. The indicator
light can be turned on/off through the APP, as well as the hold
time, detection range (sensing distance), scene selection and
connection.
4. Application Notice
1) The sensor should be installed by a professional electrician.
Please disconnect the power before installing, wiring or changing
the setting of the dial switch.
2) Put the sensor as far as possible from large areas of metal
plate, glass and other materials with high medium density to avoid
triggering by mistake.
3) Avoid the detection window of the daylight sensor of the
detector irradiated by an invalid light source, which will
interfere with the measurement of ambient light.
4) The product should not be too close to the wireless router at
least more than 2m apart, when it is installed and used.
5) Setting detecting area and indicator on-off by MH10.(Pressing HS
in MH10 makes indicator on and pressing LS in MH10 makes indicator
off.)
6) Sensor’s microwave can penetrate wall of building. It may cause
misreport when microwave penetrates wall to detect the moving
objects outside fortified area. To avoid triggering by mistake,
choose suitable place when installing, keep away from glass,
plasterboard, wooden wall and other things that microwave can
easily penetrate and choose appropriate sensing parameters
according to space, for examples:
A. When product is used in the room whose length and width is about
2m or less, detecting area should be set to 25% (application
scenario: washroom, sitting room )
B. When product is used in the room whose length and width is about
3m, detecting area should be set to 50% (application scenario:
washroom, hallway, sitting room )
C. When product is used in the room whose length and width is about
4m, detecting area should be set to 75% (application scenario:
small office, meeting room, library )
D. When product is used in the room whose length and width is about
5m or more, detecting area should be set to 100% (application
scenario: large office, meeting room, library )
Note: The setting detecting area depends on the actual environment
(detecting area parameters above application scenario are for
reference only).
7) Hold time setting: space of one person: 1-3 minutes, space of
more than one person: 30 seconds to 1 minute. It is not recommended
to set a hold time of more than 5 minutes, so as to avoid the small
motion signal in the space from interfering with the hold-time
closing.