Microwave Motion Sensor Stand-alone Minor Motion Sensor with Daylight Harvesting for Office Application MSA012

 


1. Features
 

1) Adopt Merrytek patented Minor motion detecting technology for small movement ,suitable for offices, conference rooms, classrooms and other applications

 

2) Anti air conditioning, fans and other interference;

 

3) Built-in daylight harvesting technology to achieve accurate constant light

 

4) Parameters can be adjusted by remote control or DIP switch

 

5) Equipped with infrared remote control, the transmitting Angle can be adjusted to accurately adjust the target sensor;

 

6) Wide voltage 120-277vac input, common in European and American markets;

 

7) Supports flush-mounted stand-alone installation


 

2. Parameters

 

InputOperating voltage108-305VAC 50/60Hz
Rated voltage120V/277VAC 50/60Hz
Stand-by power<1W
Surge testN—L: 1kV
OutputWorking modeON/OFF 1-10V dimming
Type of loadInductive or resistive
Load capacity

400W (Inductive) 800W (resistive) @120V AC

800W (Inductive) 1000W (resistive) @277v AC

Max.surge capacity50A (50% Ipeak, twidth =500uS, 277Vac full load, cold start); 80A (50% Ipeak, twidth =200uS, 277Vac, full load, cold start)
Dim interface1-10V Dimming< 50mA(Non-constant source)
wiring modePress the terminal
Sensor parametersOperating frequency5.8 GHz ±75 MHz,ISM band
Transmitting power0.5mW Max.
Hold time

5S/30S/1min/3min/20min/30min

(remote control Settings: 30 s / 5 s / 1 min / 3 min / 5 min, 10 min / 20 min / 30 min)

Stand-by dim Level10/20/30/50% (remote control setting: 10/20/30/50%)
Stand-by Period

0 s / 1 min / 3 min / 10 min / 30 min / + up

(remote control Settings: 0 s / 10 s / 1 min / 3 min / 5 min, 10 min / 30 min/Disable)

Detection Area100%/50%(remote control Settings:100%/75%/50%/25%)
Daylight Sensor5lux/15Lux/30Lux/50Lux/100lux/150lux/Disable
Detection range (radius)3-5m (ceiling mounting;3m)
Mounting heightsupport 6m Max.
Detecting Angle150°(wall mounting) 360°(ceiling mounting)
Operating envrionmentOperating Temperature-25℃…+55℃ Humidity: 85% (non-dew)
Storage Temperature/humidity-40℃…+80℃ Humidity: 85% (non-dew)
Certificate StandardsSafety standardsEN61058-1
Environmental RequirementCompliant to RoHS
CertificateCE RoHS
OthersWiring"L N ground" port diameter: 0.75-1.5 mm2 "1-10v" port diameter: 0.75-1.0 mm2
IP RatingIP20
Protection ClassClass II
InstallationBuilt-in
Installation imensionØ70-Ø80
PackageWhite box + flat card + outer box (K=A)
Net weight153.2g
Life time50000h @ Ta full load
Note 1. “N/A”means not available. 2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s
 

3.Function

 

People's normal working life in the body gentle motion sensing, in non-sleep conditions to achieve approximate human presence detection.

 

 

A. On-off function (WITHOUT DH)

 

 

B. 2 step dimming function (WITHOUT DH)

C. 3 step dimming function (WITHOUT DH)

 

D. On-off function (WITH DH)

E. 2 Step dimming function (WITH DH)

F. 3 Step dimming function (WITH DH)

                                                                      

 
4.Dimension (mm)
 

5. Wiring

*The sensor is recommend to connect one load only. Connect more than one loads need to consider the load and surge capacity.

 

6. Structure

 

 

 

 

7. Detection pattern

 

1)Ceiling mounting

 

Horizontal installation: 3m Sensor range setting:

100%/75%/50%/25%

Horizontal installation:6m

Sensor range setting:

100%/75%/50%/25%

 


8. Dip switch settings

 

The control of indicator light

 1 
ONTest
-Normal

 

Detection Area

 2 
ON100%
-50%
 

Hold Time

 345 
ONONON5S
-ONON30s
ON-ON1min
--ON3min
ONON-20min
---30min

 

Stand-by Period

 123 
ONONON0S
-ONON1min
ON-ON3min
--ON10min
ONON-30min
---+∞

 

 

 


Daylight Sensor

 6789 
ONONONON5Lux
-ONONON15Lux
ON-ONON30Lux
--ONON50lux
ONON-ON100lux
ONONON-150lux
VII----Disable
 

 

 

Stand-by DIM Level

 45brightnessConstant voltage output
ONON10%1.5±0.1V
ON-20%2V±0.1V
-ON30%3V±0.1V
  •  
-50%5V±0.1V
 
 

9. Remote control

 

 

10. Canceling the sensor function

The sensor function can be canceled by quick Switching off/on 3 times within 2 seconds. Turn off/on the power again to recover sensor function .

 

11. Initialization

The light will turn on 100% brightness in the initial energizing sensor, and turn to low brightness 10 seconds later (the brightness set by stand-by dim level). During initialization, no external motion sensing signal will be detected.

 

12. Factory setting

The control of indicator light:normal Detection Area:100% Hold Time:5S Daylight Sensor:Disable Stand-by Period: 0S Stand-by DIM Level:10%

 

13. Application notice

       1. The interval between multiple installations is 3m.

       2. The use of Daylight harvesting functions need to use with MH10 remote control to use.

       3. The product is switched on and off three times in a row within 2S, and the product enters the normally bright mode.

       4. The product is set by remote control. After each setting is successful, the load light will flash once, which means the setting is successful.

       5. There should be no metal plate, glass cover and other materials with high medium density in front of the sensor, which is easy to trigger by mistake.

       6. If it cannot be installed in a room that vibrates for a long time, the vibration signal will be regarded as a mobile signal to trigger the sensor.

       7. Turn off the indicator light in normal use to avoid affecting the constant light control!The first dial code needs to be set to OFF state

 

Hot Products

Microwave Motion Sensor Designed for Slim Lights with Large Detecting Area MC095S for slim lamps ...
High Frequency Microwave Motion Sensor Dimmable Motion Sensor MC083V Description High installation ...
Microwave Motion Sensor MC090S U, Batch over FCC, 120-277VAC, Superior Immunity to Interference 1. ...
Microwave Motion Sensor MC090S U, Batch over FCC, 120-277VAC, Superior Immunity to Interference 1. ...
High Frequency Microwave Motion Sensor Dimmable Motion Sensor MC083V Description High installation ...
High Frequency Microwave Motion Sensor Dimmable Motion Sensor MC083V Description High installation ...