Home Companies Hangzhou Haina Environmental Protection Tech Co., Ltd.

8 Inch Ultra Low Pressure Industrial RO Membrane Bw 8040 Ulp-8040 Nsf RoHS

Hangzhou Haina Environmental Protection Tech Co., Ltd.
Active Member

Contact Us

[China] country

Address: No. 2 Xiuyan Road, Hangzhou City, Zhejiang Province

Contact name:Robert Wang

Inquir Now

Hangzhou Haina Environmental Protection Tech Co., Ltd.

8 Inch Ultra Low Pressure Industrial RO Membrane Bw 8040 Ulp-8040 Nsf RoHS

Country/Region china
City & Province hangzhou zhejiang
Categories Water Treatment
InquireNow

Product Details

Industrial 8-inch Ultra Low-Pressure RO Membrane for Water Treatment Purifier RO System

 

All raw water contains microorganisms: bacteria, algae, fungi, viruses and other higher organisms. When the microorganisms in the feed water enter the reverse osmosis and nanofiltration systems, they will settle and condense on the surface of the membrane to form a biofilm, which will form a biological fouling when the biofilm reaches a certain thickness. The biological fouling of membrane elements will seriously affect the performance of the reverse osmosis system, and the pressure difference between the influent and the concentrated water will increase rapidly. Due to the barrier of the microbial membrane, the effective pressure of the system operation will also be reduced, resulting in a decrease in the system desalination rate.

 

Characteristics of reverse osmosis membrane biofouling

The biofouling of reverse osmosis membranes is difficult to thoroughly clean mainly because the content of microorganisms including bacteria, algae, fungi and their viruses in water is very large and grows rapidly. Once a bacterial community appears on the membrane surface, a slime film will soon be formed. At the same time, the biological slime film is insoluble in acid and insoluble in alkali, and cannot be easily removed even if it is frequently washed with cement. However, if the biological fouling of the reverse osmosis membrane is not cleaned in time, it will easily cause the system inlet water pressure to increase, the pressure difference to increase, and the water production to decrease. Generally speaking, the first reverse osmosis membrane is seriously polluted by organisms, and the membrane surface and flow channel pollution will occur at the same time. Once we find that any position of our reverse osmosis membrane is generally because the pressure difference of the front-end element increases rapidly, the feed water pressure rises rapidly , if the salt transmission rate generally increases, it is necessary to consider whether the membrane element is subject to biological fouling.

 

Performance

 

Model NumberDescription8040-ULP
Performance &
Test Condition
The Desalination Rate %99.2%
Water Rate GDP10500
The Test pressure150psi
Test solution Temperature25± 1ºC
Test Solution Concentration (1:1:1) labeling1500ppm
Test solution PH value6.5-7.5
Recovery Of Single-Branch Membrane Element15%
Feed water SDI5

 

Dimension of Membrane

 

 

Operating Limit:

Maximum Operating Temperature113ºF(45ºC)
Maximum Working Pressure600psi(41.0 bar)
The high pressure drop15psi (1.0bar)
Continuously operating PH range a3-10
Short wash PH range (30min) b2-12
Maximum feed water SDISDI 5
Tolerance Of Free Chlorine<0.1ppm
Maximum pressure drop for single membrane element15psi(0.1Mpa)

 

 1.When PH is above 10, the Maximum Temperature of Continuous Operation is 35ºC.

 

 2.Under certain conditions, the presence of free chlorine and other oxidants in the water may cause serious membrane damage, which doesn't belong to product warranty range.

 

 

 

 

FAQ:

 

1. Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.


2. Q: Should we use our logo/brand?
A: Yes, OEM is absolutely supported. But for some items quatity is 500pcs.

 

3. Q: What is the filtering accuracy of RO membrane?
A: RO meembran filtering accuracy is 0.0001um.

 

4.RO membrene desalination rate and service life ?
A: RO meembran desalination rate more 98%,service life according to water quality 2-3years


5. Q: What is the payment?
A: Usually we offer two payment terms: by Alibaba or by TT. L/C and D/A.


6. Q: How long time have your company in water treatment?
A: We have more than 18 years experience in water treatment equipment/water treatment solution.


7.Q:What's the certification do you have?
A: We have NSF, ISO9001, OHSAS18001, ISO14001 Certifications.

Hot Products

Industrial 2521 RO Membrane for Industrial & Commercial RO Water Purifier Treatment Specification ...
Brackish Water RO Membrane for Brackish Water Purifier Reverse Osmosis Membrane Specification Model ...
Extra Low Pressure Industrial 4040 Reverse Osmosis RO Membrane for RO Water Purifier Reverse osmosis ...
Industrial 8-inch Extra Low-Pressure RO Membrane for Water Treatment Purifier System How to clean ...
Industrial 8-inch Ultra Low-Pressure RO Membrane for Water Treatment Purifier RO System All raw ...
BW 4040 ULP Reverse Osmosis RO Membrane for Industrial RO Water Purifier The osmotic pressure of ...