BSC Biosafety Cabinet Features:

1.  High-quality material front window.
2.  Timing function.
3.  HEPA filter life and UV life indicator.
4.  Automatic wind speed with filter is adjustable.
5.  With power-off memory function.
6.  Audiovisual alarm (abnormal airflow speed; filter replacement; front window is at an unsafe height.)
7.  The working area is surrounded by negative pressure, which can ensure the maximum safety of the working area.
8.  Audiovisual alarm (filter replacement, high-altitude windows, abnormal airflow speed, etc.)
9.  Remote control: all functions can be realized, making the operation easier.
10.  Interlocking function; UV lamp and front window; UV lamp and blower, LED lamp; Blower and front window.

 

ModelBSC-1300B2
Clean GradeHEPA:ISO 5 calss ( Class100 )
ULPA:ISO 4 Class ( Class10 )
HEPA FilterHEPA:≥99.995% , @0.3μm
ULPA:≥99.999% , @0.12μm
Air tightness99.99≤E≤99.999
Overall Dimensions1500×800×2120mm
Working Space1300×700×600
mm
Downflow Velocity0.35m/s
Forward intake wind speed0.25m/s±0.025m/s

 

Principles for choosing BSC Biosafety Cabinet in biosafety laboratories:

When the laboratory level is level 1, there is generally no need to use a biological safety cabinet or a level I biological safety cabinet. When the laboratory level is level two, when microbial aerosols or spills may occur, a level I biological safety cabinet can be used; when handling infectious materials, a level II biological safety cabinet with partial or full ventilation should be used ; If it involves handling chemical carcinogens, radioactive substances and volatile solvents, only Class II-B full exhaust (B2 type) biological safety cabinets can be used. When the laboratory level is level three, a level II or level III biological safety cabinet should be used; all operations involving infectious materials should use a fully exhausted type II-B level (B2 type) or level III biological safety cabinet. When the laboratory level is level four, a level III full exhaust biological safety cabinet should be used. When personnel wear positive pressure protective clothing, a Class II-B biological safety cabinet can be used.

Installation of BSC Biosafety Cabinet:

1.  The biological safety cabinet shall not be placed on its side, impacted, or collided during transportation, and shall not be directly attacked by rain, snow, or sun exposure.

2.  The working environment of the biological safety cabinet is 10~30℃ and the relative humidity is <75%.

3.  The equipment should be installed on a horizontal surface that cannot be moved.

4.  The equipment must be installed close to a fixed power socket. When the external exhaust system is not connected, the top of the device must be at least 200mm away from the obstacle at the top of the room, and the distance between the back and the wall must be at least 300mm to facilitate the smooth flow of external exhaust. Maintenance of safety cabinets.

5.  In order to prevent airflow interference, it is required not to install the equipment in the passage of people, and not to make the operating port of the sliding front window of the biological safety cabinet face the door and window of the laboratory or be too close to the door and window. Places that may disturb the airflow.

6.  When used in high altitude areas, the wind speed must be recalibrated after installation.

 

 

Hot Products

BSC Biosafety Cabinet main feature: ◆ It conforms to the principles of physical engineering, and is ...
BSC Biosafety Cabinet main feature: 1. It conforms to the principles of physical engineering, and is ...
Classification of biological safety cabinets: According to the NSF49 standard, the medium of ...
BSC Biosafety Cabinet Features: ◆ Small size, saving space. ◆ Centrifugal fan with adjustable speed; ...
BSC Biosafety Cabinet Features: 1. High-quality material front window. 2. Timing function. 3. HEPA ...
BSC Biosafety Cabinet Features: ◆ The shape design conforms to the ergonomic principle of 10 degrees ...