2130mm 77M2 PVDF Ultrafiltration Membrane Reverse Osmosis Membrane Types

Country/Region china
City & Province hangzhou
Categories Water Treatment
InquireNow

Product Details

KH-UF-SFX2880 Ultra-filtration Membrane System for Pure Water Purification with PVDF 0.03um pore size

The SFX series of the ultrafiltration modules are built with robust outside-in PVDF fiber technology. The hollow fibers feature high clean-ability, low chemical consumption, high recovery, and a superior combination of mechanical properties and chemical resistance. It offers customers a proven product with a long list of installations world-wide.

Advantages

  • Excellent removal of colloids, particles, and bacteria
  • Low chemical consumption
  • Ability to treat challenging feed water with limited pretreatment
  • High chemical-resistance PVDF that allows aggressive chemical use for treating challenging water when needed
  • Mechanically strong fibers enabling long module life

Important information

Proper start-up of a UF system is essential to prepare the membranes for operating service and to prevent membrane damage. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved. Before initiating system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration and other system checks should be completed. Please refer to the product technical manual.

Operation guidelines

Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. Flush the UF system to remove shipping solution prior to start up. Remove residual air from the system prior to start up. Manually start the equipment. Target a permeate flow of 60% of design during initial operations. Depending on the application, permeate obtained from initial operations should be discarded. Please refer to the product technical manual.

General information

  • If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void.
  • To prevent biological growth during system shutdowns, it is recommended that preservative solution be injected into the membrane module
 

 

 

 

 

Size and weight

 

ModelKH-UF-SFX2880-PVDF
Module Diameter (OD, mm)Φ225 mm
Module Length ( L1, mm)2000 mm
Module Length (L2, mm)2130 mm
Module Length (L3, mm)2320 mm
Module Length (L , mm)2360 mm
Operating TypeOutside to Inside
Membrane Area77 m2
Dry weight of the module62 Kg

 

 

 

 

 

Parameters

Shell materialUPVC
Membrane MaterialPVDF
Membrane pore size0.03μm
Inner diameter of the hollow fiber0.7 mm
Outer diameter of the hollow fiber1.3mm
Turbidity of Permeating water≤ 0.2 NTU

SDI value of permeating water

 

≤ 3

Flux rate of purified water

(0.10MP,20℃)

≥ 8000L/H

 

 

 

 

Typical Process

 

Temperature Range5-45 ℃
PH Value Range2-13

Permeating Flux rate for different

Water

40 -80 l/m2/hr
Operating Pressure≤0.12MPa
Maximum Inlet Pressure0.2MPa
Backwashing flux rate

1.5-2.0 times of

Permeating Flux

Backwashing timesOnce per 30-120 minutes
Chemical cleaning online during backwashingOnce per 7-14 days

 

ac.png

 

FEATURES

The Ultrafiltration (UF) modules are made from high strength, hollow fiber membranes that have excellent features and benefits:

  • 0.03 μm nominal pore diameter for removal of bacteria, viruses, and particulates including colloids to protect downstream processes such as RO
  • PVDF polymeric hollow fibers for high strength and chemical resistance allows long membrane life
  • Hydrophilic PVDF fibers for easy cleaning and wettability that help maintain long term performance
  • Outside In flow configuration for high tolerance to feed solids that help reduce the need for pretreatment processes
  • U-PVC housing, helping to eliminate the need for costly pressure vessels

This module is an ideal choice for systems with capacities greater than 50 m³/hr (220 gpm). Larger and longer, 8 inch diameter and 80 inch in length, together with an increase in packing density of 10,000 fibers, this module offers the highest effective membrane area of the ultrafiltration modules. The 2880 contributes to a more economical membrane system design.

The ultrafiltration Modules can be used for a wide variety of treatment applications such as surface water, seawater, industrial wastewaters, and secondary effluent wastewater.


APPLICATIONS
  • Ground water and surface water treatment
  • Seawater desalination pretreatment
  • Waste water treatment

Proper start-up of a UF system is essential to prepare the membranes for operating service and to prevent membrane damage. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved. Before initiating system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration and other system checks should be completed. Please refer to the product technical manual.

Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. Flush the UF system to remove shipping solution prior to start up. Remove residual air from the system prior to start up. Manually start the equipment. Target a permeate flow of 60% of design during initial operations. Depending on the application, permeate obtained from initial operations should be discarded. Please refer to the product technical manual


The whole installation and application process of our UF modules are described as the following photo:

 

 

Hot Products

SFX2860 Ulta-filtration Membrane Modules for Purified Water Treatment with Pore Size 0.05um PVDF ...
Small Ultra-filtration Membrane System for Pure Water Purification with PVDF material 1. UF ...
Ultra-filtration Membrane System for Pure Water Purification with PVDF 0.03um pore size Ultrafiltrat...
CNKHONG 8" PVDF Ultrafiltration Membrane Equipment for Water Treatment SFX2860 Ultrafiltration ...
KH-UF-SFX2880 Ultra-filtration Membrane System for Pure Water Purification with PVDF 0.03um pore ...
KH-UF-SFX2860 Ultra-filtration Membrane System for Pure Water Purification with PVDF 0.03um pore ...