MS26 Newborn blood oxygen saturation detector monitoring baby heart rate heartbeat oximeter baby children oximeter

Country/Region china
City & Province harbin shandong
InquireNow

Product Details

MS26 Newborn blood oxygen saturation detector monitoring baby heart rate heartbeat oximeter baby children oximeter

 

Packaging Details
Package Contents:
- 1pcs fingertip oximeter (PE bag)
- 1pcs lanyard
- 1pcs white card lining
- 1pcs English user manual
- 1pcs color box

Single package volume: 9cm * 7cm * 6cm
Unit weight: 0.2kg/unit(without battery)
Carton volume: 43cm*34cm*20cm, 100pcs/carton
Gross weight: 7.0Kg/box (without battery)
 
Product introduction:
 
This Fingerclip Pulse Oximeter is an affordable and accurate way to measure pulse rate and oxygen saturation with your finger. It can not only accurately measure blood oxygen (SPO2) but also display the blood oxygen volume waveform and pulse intensity bar graph, which ensures the accuracy and comprehensiveness of the measurement. The unique perfusion index (PI) effectively reflects the pulsatile blood flow, self-adjusting finger clips and simple one-button design are easy to operate, suitable for daily use, and measure your health status at any time. The M170 oximeter is small in size and easy to carry, and you can observe your blood oxygen status at any time during daily travel. It is widely used in homes, hospitals, oxygen bars, sports health care (used before and after exercise, not recommended during exercise), community medical care and other places. It is suitable for plateau tourism and mountaineering enthusiasts, patients (patients who have been recuperating at home for a long time or patients in emergency state), elderly people over 60 years old, people who work more than 12 hours a day, sports people (professional sports training or sports enthusiasts), Confined environment workers, etc. This product is not intended for continuous patient monitoring.
 
Product features:
1. Display parameters: Blood oxygen SPO2 value, pulse PR value, blood oxygen volume map, pulse intensity bar graph, PI (perfusion index) sleep monitoring (ODI)
2. Display screen: The product adopts blue and yellow two-color OLED screen display, 5-level
brightness adjustable
3. Display mode: Four directions, six display modes
4. Energy saving and environmental protection: The product has low power consumption and can be used for more than 30 hours with two AAA batteries
5. Voltage warning: When the battery voltage is too low and may affect normal use, there is a low voltage warning prompt
6. Automatic shutdown: When no signal is generated, the product will automatically shut down after 8 seconds
7. Advantages: It integrates the blood oxygen probe and the processing and display module. The product is simple to use, low power consumption, small size, light weight and easy to carry.

 

 

★Product parameters:

 

Blood oxygen measurement range: 35%~100% PR measurement range: 30BPM~250BPM Blood oxygen measurement accuracy: ±2% in the range of 70%~100%, ≤70% undefined PR measurement accuracy: ±1BPM or ±1% of the measured value (whichever is greater) Blood oxygen resolution: ±1% Perfusion index: ≥0.2%, ±0.1% Automatic shutdown: when no finger is inserted, it will automatically shut down in 8 seconds Operating temperature: 5~40℃ Storage humidity: 15%~80% when working, 10%~80% storage Atmospheric pressure: 70Kpa~106Kpa Battery model: 2*1.5V (2 AAA alkaline, the product does not contain batteries) Material: ABS+PC
 

★Heart Rate Pulse Repetition Rate (PR) BPM:

 

Measuring range: 30 bpm - 250 bpm bpm unit of measure: 1 time Accuracy: 1% or 1 bpm Heart Rate (Heart Rate): refers to the number of times the heart beats per minute. That is, in a certain period of time, the heart beats fast or slow. In the same person, the heart rate slows down during quiet or sleep, and increases during exercise or agitation!
★Monitoring parameter SpO2:
Oxyhemoglobin Saturation (SpO2) Patient Type: For all persons over 4 years old Measurement range: 70 - 99% Resolution: 1% Accuracy: Within 70% - -99%±2% Oximeter saturation: an important indicator that reflects the oxygen status in the body. It is generally believed that the normal value of blood oxygen saturation should not be lower than 94%, and below 94% is regarded as insufficient oxygen supply.
 

★Blood perfusion indicates PI value:

 

Measuring range 0.2%-30% PI Resolution: 1% PI refers to the perfusion index (Perfusion Index, PI), and the PI value reflects the pulsatile blood flow, that is, the blood perfusion ability. The greater the pulsatile blood flow, the greater the pulsatile component and the greater the PI value. Therefore, both the measurement site (skin, nails, bones, etc.) and the patient's own blood perfusion (arterial blood flow) will affect the PI value. Since sympathetic nerves affect heart rate and arterial blood pressure (affecting pulsatile arterial blood flow), the body's neuromodulation system or mental state also indirectly affects PI values. Therefore, under different anesthesia states, the PI value will also be different.
 

★Sleep monitoring storage memory function ODI 

 

The sleep recording is recorded as a waveform function. It can record up to 8 hours of waveform data! And it is stored in the form of memory, which is convenient for users to investigate and deal with the data by themselves! Data can be provided to professional doctors for effective sleep disorder treatment! ODI=oxygen desaturation index is the number of times the arterial oxygen saturation drops by more than or equal to 4% per hour on average during sleep
 

★Precautions:

 

1. Avoid exposure or direct sunlight
2. Avoid measuring in motion, don't shake your fingers
3. Avoid extreme radiation of infrared or ultraviolet radiation
4. Avoid contact with organic solvents, mist, dust and corrosive gases
5. Avoid using it near radio frequency transmitting devices or other electrical noise sources, such as: electronic surgical instruments, mobile phones, two-way wireless communication equipment for vehicles, electronic appliances, high-definition TVs, etc.
6. This instrument is not suitable for infants and newborns, only for children over 4 years old and adults.
7. After the pulse rate waveform is normalized, when the pulse rate waveform tends to be smooth and stable, the measured value read is a normal value, and the pulse rate waveform at this time is also standard.
8. The finger of the tested person should be clean, and the nails should not be coated with cosmetics such as nail polish
9. Fingers are inserted into the rubber holes, the fingernails must be facing up, in the same direction as the display
 

Hot Products

Fetal Heartbeat Doppler Detector Baby Care The Device Listen To The Baby's Heart Beat Fetal ...
MS26 Newborn blood oxygen saturation detector monitoring baby heart rate heartbeat oximeter baby ...
BC401 Urine Analyzer is a high-precision, intellectual instrument which is researched and developed ...
Product Description The charging nano-blue light atomizer needs to be fully charged before use, each ...
Product Description LUBAR SUPPORT DECOMPRESSION BELT Specification item value Place of Origin China ...
Product Description before getting air after getting air The inflatable air column pulls in the up ...