Home Companies Zhejiang Hengrui Technology Co., Ltd.

48V 100AH Telecom Battery Anti Reverse

Zhejiang Hengrui Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: 8F, Building 3, Tianxing International Center, No. 508 Fengtan Road, Hangzhou, China. 310011

Contact name:Yang

Inquir Now

Zhejiang Hengrui Technology Co., Ltd.

48V 100AH Telecom Battery Anti Reverse

Country/Region china
City & Province hangzhou zhejiang
Categories Other Batteries
InquireNow

Product Details

48V 100AH 19”Standard Cabinet Telecom Lithium Ion (LiFePO 4 ) Battery Pack 482.0mm X D 540.0mm X H133.0mm

  • Product Overview

 

The 48V Lithium Ion Battery Pack is mainly working as 48VDC backup power source, and it consists of 15 cells of Lithium Iron Phosphate Battery Cells connected in series and telecom specialized high performance and high reliability Battery Management System (BMS). The battery’s +/- output terminals are connected to the +/- terminals of rectifier. When the mains supply is normal, telecom equipment is powered by mains through rectifier and battery pack is also charged through rectifier; When the mains supply is outage, the 48V lithium ion battery pack is supplying power to telecom equipment without any time-delay to ensure telecom equipment is powered without any interruptions, until mains supply resumed or protective power cut-off by BMS due to over-discharge protection activated automatically.​

 

  • Features and Benefits​
  • Host computer control function

1) Through the host computer to set the protection parameters such as overvoltage, undervoltage, overcurrent, overtemperature, under temperature, short circuit, as well as balance, sleep, capacity, and other functional parameters and various alarm parameters.

2) Supporting monitoring of battery pack related information, battery status information, etc.

3) Supporting storing and exporting related data

4) Supporting writing barcode

5) Remote Control and Telemetering

 

  • Serial port upgrade function

The management system can be upgraded via the RS485 interface.

Communication Protocols

Default setting protocol with baud rate 9600, and other protocols are also supported.

 

  • Charge current limiting function

After the current limiting module is assembled and enabled by the host computer, the charging current limiting function can be implemented. The current limiting mode is current limiting after charging and overcurrent; the current limiting value is 10 ± 1A.

 

  • Anti-reverse function

Battery has Anti-reverse circuit. After the system is powered on, the protection board will be burnt due to the reverse connection of the battery during parallel installation.

 

  • Parallel communication function

The parallel communication function can be realized through the RS485 interface, and it can support up to 6-digit DIP switches (typically 4-digit DIP switches) for setting addresses when communicating in parallel. After parallel connection, the battery pack data can be monitored cyclically through the parallel version of the host computer.

 

 

  • Data Storage

Battery supports no less than 500 battery status data storage functions, protects all data and regular historical data during all state transitions, and stores 1 historical data every hour.

 

  • Product Specification​
ItemSpecificationRemarks
Nominal Capacity100AhStandard discharge (1) capacity after standard charge (2)
Nominal Voltage48.0VConfiguration: 15S2P - VHR 3914895LFP-50Ah. Voltage of single cell is 3.2V.
Charge Voltage54.75V 
Voltage at End of Discharge41.0V 
Floating Voltage51.0V 
Maximum Continuous Charge Current (CC Threshold)100A 
Over Current Protection for Charge105A ± 3AN.A.
Over Voltage Protection3.80V/cellN.A.
Maximum Continuous100A 
Discharge Current
Over Current Protection for Discharge105A ± 3AN.A.
Under Voltage Protection2.75V/cellN.A.
Operation AllowableCharge: 0~60°CN.A.
Temperature RangeDischarge: -20~60°CN.A.
Continuous Discharge Power0.9kW50%SOC
Continuous Charge Power0.9kWN.A.
Self-discharge Rate/Month≤3%@ 25 ± 3℃,50%SOC
Cycle Life(cycles)≥5000@ 25 ± 3℃,80%DOD, 0.2C/0.2C
Operation Allowable≤95% RHOperation
Humidity Range≤85% RHStorage
Recommended0~40°CMax. 6 month
Storage temperature
WeightAbout 46kgN.A.

 

 

Basic Parameter

ItemSettableDetailed InformationDefault Setting ValueRemark
(Yes or No)
Charge Current LimitNoLimited Charge Current Value105AAcceptability range:105 ± 2A
YesMethod of Charge Current LimitOvercharge activates current limitN.A.
Sleep VoltageYesSleep Voltage Set Value3.30 VAcceptability range: 3.3 ± 0.02V
BMS Power consumptionNoInternal Circuit Power Consumption at Mode 1 – Fan is not activated or for natural cooling model with heat radiator≤ 40 mAN.A.
NoInternal circuit power consumption during sleep≤ 500 uA
Charge BalancingYesBalancing Activation Voltage Value3.40 VN.A.
YesBalancing Activation Voltage Difference Value50 mV
NoBalancing current70 mA
Full Charge SettingYesConstant voltage value54 ± 0.3VDuring constant voltage charging, when the overall voltage is greater than the constant voltage and the current is less than the constant current value, the BMS will assume that the battery capacity is fully charged and the charging MOSFET will be cut off.
YesConstant current value5.0A
Standby TimeNoInterval days of forced recovery charge after overcharge0In order to ensure the battery capacity, after the battery over-voltage protection, the battery will be forced to resume charging after a fixed time; when the time is configured to 0, this function does not work.
Under-voltage OFF TimeNoDischarge MOS turn-on interval time after undervoltage0In order to be compatible with the traditional lead-acid charger charging method, the BMS periodically closes the discharge MOSFET for about 7.5 seconds after undervoltage protection, so that the charger detects the battery voltage and turns on the charging. The interval period of the closed discharge MOSFET can be set. When configured to 0, this function does not work.
Capacity SettingYesFull capacity setting100AhN.A.
YesResidual capacity setting50Ah

 

 

  • Communication Interfaces Description

RS232 adopts 6Pin straight PCB welding socket (RJ11) to provide RS-232 protocol, the Pin assignment of RJ11 is defined as follow:

 

 

 

S485 adopts 8Pin straight PCB welding socket (RJ45) to provide RS-485 protocol, the pin assignment of RJ45 is defined as follow:

 

 

  • Prohibitions
  • Do not use different charger to charge the battery.
  • Do not charge with constant current higher than maximum charge current allowed.
  • Do not disassemble or reconstruct the battery.
  • Do not throw or cause impact.
  • Do not pierce a hole in the battery with sharp objects, such as nail, knife, pencil, drill, etc.
  • Do not mixing with other batteries.
  • Do not solder on battery directly.
  • Do not expose the battery to high heat, such as fire, etc.
  • Do not put the battery into a microwave or high-pressure container.
  • Do not use the battery in reverse.
  • Do not connect positive (+) and negative (-) with conductive materials, such as metal, cables, etc.
  • Do not immerge or wet battery with water or sea water

 

 

Hot Products

12 V 155AH Lead-acid Batteries with Long Life of 12 Floating Charging Conditions,L558mm x W112mm x ...
OPzV12-200 12V Tubular Gel Batteryfor Renewable Energy System , 499 x259 x 219 mm Product Overview ...
OPzV12-150 12V Tubular Gel Batteryfor Renewable Energy System , 532 x210 x 216 mm Product Overview ...
48V 50AH 19”Standard Cabinet Telecom Lithium Ion (LiFePO 4 ) Battery Pack 440.0mm X D 390.0mm X H132...
48V 100AH 19”Standard Cabinet Telecom Lithium Ion (LiFePO 4 ) Battery Pack 482.0mm X D 540.0mm X ...
2 V 250AH OPzV Tubular Gel Battery for renewable energy, telecom and other cyclic and standby harsh ...