Acti9 C120 Industrial Circuit Breaker 63A~125A, 1P,2P,3P,4P for Circuit Protection AC230V/400V Home or Industrial Use

Country/Region china
City & Province wuxi jiangsu
Categories Battery Chargers
InquireNow

Product Details

Acti9 C120 

CHINT Made In China

AC Use Miniature Circuit Breakers 63~125A, 

 

Miniature Circuit Breakers for AC Current circuits, offering terminal distribution installation protection

 

C120H circuit breakers are multistandard circuit breakers that combine the following functions:
- Protection of cables against overloads and short-circuits in final distribution
- Manual control and isolation
- Earth leakage protection when combined with a Vigi C120 module without temperature derating: compliance with EN 61009
- Remote tripping, indication, by adding auxiliaries common to the entire C65 range.

  • Compliant with IEC60898-1, IEC60947-2
  • Available in 1P, 2P 3P, 4P
  • C, D tripping curve
  • Up to 500V AC.

 

General rules for choosing MCB
Technicala data of the network at the point considered:
The earthing systems(TNS,INC),Shrot-circuit current at the circuit-breaker installatino point,which must always be less than the breaking capacity of this device,Networl normal voltage.

DIN rail Miniature Circuit Breakers (MCB) offering circuit protection against short-circuit and overload currents. Suitable for isolation in compliance with IEC 60947

  • Features

Acti9 C120 DIN rail, miniature circuit breakers offer extensive features that provide maximum safety and continuity of service while minimizing service and intervention time:

  • Nominal current: 63 to 125 A
  • Large choice of breaking capacities and tripping curves (B, C, D)
  • Compliant with IEC EN 60898 or IEC 60947-2 depending on the version
  • Suitable for isolation: compliant with IEC 60947
  • VisiSafe provides a visible green indicator showing which circuits are disconnected and safe for maintenance operations
  • Operating voltage: up to 440 V AC
  • Insulation voltage: 500 V AC
  • IP20 terminal insulation
  • Optional add-on residual current device modules: Acti9 C120 Vigi
  • Optional electrical auxiliaries for remote Open/closed status or remote tripping of Acti9 C120 circuit breaker with shunt, overvoltage and undervoltage release.


 

Benefits

Longer product service life thanks to:

  • Good overvoltage withstand capacity: products are designed to offer a high industrial performance level (degree of pollution, rated impulse withstand voltage and insulation voltage)
  • High limitation performances
  • Fast closure independent of toggle operating speed.

Applications

  • Protection of electrical circuits in all industrial and commercial buildings
  • Particularly suited to higher ratings applications.

 Standard IEC/EN 60947-2
Electrical featuresRated current InA63,80,100,125
Poles 1P,2P,3P,4P
Rated voltage UeV230/400
Insulation voltage UiV500
Rated frequencyHz50/60
Rated breaking capacityKa6~10
Rated impulse withstand voltage(1.2/50)UimpV6000
Dielectric test voltage at ind.Freq.for 1 minKv2.5
Pollution degree 3
Thermo-magnetic release characteristic 8-12In
Mechanical
features
Electrical life 1500(In=63A,80A,100A)
1000(In=125A)
Mechanical life 8000(In=63A,80A,100A)
7000(In=125A)
Contact position indicator Yes
Pollution degree IP20
Standard IEC/EN 60947-2
Reference temperature for
setting of thermal element
30
Ambient temperature-5...+40(Special application please refer to P29 for temperature compensation correction)
Combination
with
sccssorles
(with daily average≦35℃) 
Storage temperation Terminal connection type-25..+70
 Cable/pin-type busbar
Terminal size top/bottom for cablemm250
AWG18-1/0
Terminal size top/bottom for busbarmm250
AWG18-1/0
Tightening torqueN*m3.5
In-Ibs.3.1
Mounting On DN rail EN 60715(35mm)by meas of fast clip device
Connection
Auxilary contact
 From top
Auxilary contact Yes
Rated current
In (A)
Temperature compensation coefficient under various operational temperature
 -10℃0℃10℃20℃30℃40℃50℃55℃60℃
631.281.211.141.071.000.840.870.850.82
801.221.161.111.051.000.950.910.880.86
1001.221.181.111.051.000.950.910.880.88
1251.221.161.111.051.000.950.910.880.86

 

Hot Products

MCB DZ47-60, C45 CHINT Made In China AC Use Miniature Circuit Breakers 6~63 A, 80~125A, Miniature ...
Acti9 C120 CHINT Made In China AC Use Miniature Circuit Breakers 63~125A, Miniature Circuit Breakers ...
Chint NXB Miniature Circuit Breaker 1~63A, 80~125A, 1P,2P,3P,4P for Circuit Protection AC230/400V ...
Chint NXB-40 DPN Miniature Circuit Breaker 6~40A, Icn=4500A, 1P+N 18mm single module for Circuit ...
MCB DZ47LE-63 CHINT Made In China AC Use Miniature Circuit Breakers 6~63 A Miniature Circuit ...
Schneider EZD Molded Case Circuit Breaker 3,4 Pole 15~100A,125~630A 25kA, 36kA, 50kA, 380V 415V Icu ...