Home Companies Chongqing Chuangxiang Power Source Co., Ltd.

Small 6 Volt 4ah Rechargeable Battery , Dry Charged Sealed Lead Acid Battery 6v 4ah

Chongqing Chuangxiang Power Source Co., Ltd.
Active Member

Contact Us

[China] country

Address: 8# JINSHAN AVEN, JINLONG INDUSTRY PARK, TONGLIANG DISTRICT, CHONGQING, CHINA

Contact name:

Inquir Now

Chongqing Chuangxiang Power Source Co., Ltd.

Small 6 Volt 4ah Rechargeable Battery , Dry Charged Sealed Lead Acid Battery 6v 4ah

Country/Region china
City & Province chongqing chongqing
Categories Batteries
InquireNow

Product Details

Notice

 

1, Flames, sparks,burning cigarettes or other ignition sources must be kept away from battery when it is charging because the battery generates explosive gasses during vehicle operation.

2, When charging batteries, work in a well ventilated area - never in a closed room. Always turn the battery charger or ignition off before disconnecting a battery.

3, Keep out of the reach of children or the personnel who do not understand the manual. It may cause blindness or severe burn.

4, When using the battery ,handle with care,sulfuric acid may cause blindness or severe burn.

 

Lead acid battery self discharge

The self discharge characteristic of the lead acid battery is relatively good. At a room temperature of 20°C the self-discharge rate is around 3% per month> In theory a lead acid battery can be stored for up to 12 months without recharge. However at higher temperatures the self discharge is higher. At 30°C the self-discharge increases and a recharge will be needed after 6 months. Letting the battery drop below 60% for some time causes sulphation.

Sulphation is a process which reduces the capacity of lead acid batteries. During normal use, small sulphate crystals form, but these are normal and are not harmful. During prolonged charge deprivation, however, the amorphous lead sulphate converts to a stable crystalline and deposits on the negative plates. This leads to the development of large crystals that reduce the active material within the cell and result in a reduction of capacity within the cell.

 

Specifications of Small 12v lead acid white 2.5Ah rechargeable storage motorcycle battery manufacturer

 

ItemSmall 12v lead acid white 2.5Ah rechargeable storage motorcycle battery manufacturer
Code6N4-2A
ColorWhite
Dimension(±1mm) L*W*H88*85*96mm
Approx. Weight(kg)0.45kg
SeperatorPE/Fiber glass
Norminal Voltage6V
Capacity(Ah) 10hours4Ah
ContainerABS
UseageMotorcycle / Scooter /three Wheel Motorcycle
No. of plate24
MOQ500pcs
Warranty12 months
BrandChuangxiang

 

Answers to Common Questions about Batteries

1, Do lead acid batteries discharge when not in use?

 

All batteries, regardless of their chemistry, will self-discharge. The rate of self-discharge for lead acid batteries depends on the storage or operating temperature. At a temperature of 80 degrees F. a lead acid battery will self-discharge at a rate of approximately 4% a week. A battery with a 125-amp hour rating would self-discharge at a rate of approximately five amps per week. Keeping this in mind if a 125 AH battery is stored for four months (16 weeks) winter without being charged, it will loose 80 amps of its 125-amp capacity. It will also have severe sulfation, which causes additional loss of capacity. Keep your batteries charged while not in use!

 

2, Do lead acid batteries develop a memory?

 

Lead acid batteries do not develop any type of memory.

 

3, Do I need to completely discharge my lead acid battery before recharging it?

 

No, in fact you should never discharge your lead acid battery below 80% of its rated capacity. Discharging it below this point or 10.5 volts can damage it.

 

4, When do I need to perform an equalization charge?

 

Equalizing should be performed when a battery is first purchased (called a freshening charge) and on a regular basis (every 10 discharge cycles or at least once a month). Reduced performance can also be an indicator that an equalizing charge is needed.

 

5, What is an equalizing charge?

 

An equalizing charge for a 12 volt battery requires that it be charged with a voltage of at least 14.4 volts for a period of at least one hour once a month, or every 10 discharge cycles. An equalizing charge prevents battery stratification and reduces sulfation, the leading cause of battery failure.

 

 

 

Hot Products

12v 9ah Sealed Lead Acid Battery , Wet / Dry Charged 12 Volt Sla Battery BATTERIES - Wet or Dry ...
BATTERIES - Wet or Dry Charged Batteries can be produced as Wet-Charged, such as current automotive ...
Why Choose Us? 1. From Taiwan Maan Shyang Group high technology and more than 10 years battery ...
Answers to Common Questions about Batteries 1, Do lead acid batteries discharge when not in use? All ...
Notice 1, Flames, sparks,burning cigarettes or other ignition sources must be kept away from battery ...
Answers to Common Questions about Batteries 1, Do lead acid batteries discharge when not in use? All ...