86*92 LCD Touch Panel: Integrated the Control switch, background music, curtain control, and temperature control switch regulator in one.

86 LCD Touch Panel as a Central Control Collective Control Panel which is composed of three parts : "Four-way Relay Power Supply", "Main Board", "LCD Touch Control Panel".This product by using WIFI networking mode to communicate with 485, and control the external devices through 2.4G infrared. This product is upgraded and developed on the basis of 3Q's "One Gang", "Two Gang", "Three Gang", "Four Gang", "Five Gang", "Six Gang", "Twelve Gang" and "Host".

 

3Through WIFI network transmission the APP control delivered the instruction to each control panel. It can realize the combination and control of App for single area control, house area control and house scene mode.

 

4The panel contains dimming function (this function for on/off control options) : the brightness of the light when it turned on will increases from 30% to 100% gradually (this function can set the initial starting value and peak value)

 

5The communication between the panels is realized by two methods of communication which is the 485 wired and wireless network through WIFI (whether to use wired or wireless according to customer requirements).

 

6It needs to search panel IP in the same WLAN when the App adding the control switch.

 

7Support the APP control of non-local and going out (When the APP in online state, the family switch control can be controlled).

 

8 Power supply design: It reserves 220V output port, 485 port and external equipment dry contact interface (such as: air conditioning, floor heating: fresh air, curtain,roller shutter gate, security system).

9System Update : The APP reminds to download the update package through the network to each panel with one key to upgrade.

 

10.Optical inductor and human body inductor: This model be equipped with human body induction function ( turned on/off function is selectable)(Optical inductor and human body inductor can be turned on at time same time or turned on separately.)

 

 

11Panel introduction

 

12Panel introduction

13Switching on and off by light-touching

 

14Strong Current: Double wire design , null line and live line

15Weak Current: Positive and negative signal wire, double wire design with WIFI data transmission

 

16Switch design: Daylight inductor and human body inductor (In the upper rectangle)

17Switch design: Daylight inductor and human body inductor (In the upper rectangle)

18Cancel the four buttons from the bottom of the APP interface

 

K1~K4: The standby lighting loading on-off control

K5~K99: The scene mode control key and local control on/off key of non-local lighting control (including to all-off)

 

Home Key: The menu setting key for lighting control. It can be used for partitioning, interface button setting, screen and mode setting and non-local remote control options (temporarily deploy permission switch control for other area) lighting control center and other lighting menus.

 

Curtain Key: Can control the curtain motor which is connected with the panel of local area, it can also select to deploy the control permission of curtain motor which connected from other areas.

Click the relevant button to enter the curtain control center, enter into control by selecting the area which need to be controlled, it can choose to all-off or all-on or open a certain opening and closing ratio (this function with clocking on/off, timing on/off, countdown on/off)

 

Air Conditioning Key: Panel temperature control can be turned on when the panel is connected to the air conditioning control. Clicking into the temperature control for temperature regulation (Click on the button “without corresponding equipment” will be displayed when the air conditioning equipment no connected.) This function with deploy control permission for other areas through non-local control. (The APP can centralized control for each area on the temperature control clocking, timing and other mode selection.)

 

Music Key: It can enter into the music selection control center to control the player with select songs, add or subtract volume, pause playback and other controls.

Automatic Power Off Function: automatically turns into shutdown when Power failure.

Power Cut Memory Function: It can memorize the before power cut set status of various match-code and scenarios mode.

Remote Control Function: Through the Internet, the remote control function of network APP can be implemented.

Scenes Setting Function: Control the Menu Settings through panel lighting.

Wake-up function: When the panel turns black, by light-touching will turn on the wake function for 5 seconds to check the lighting status in real time.

Luminous Indication Function: It can indicate the position of the switch in the dark, the luminous automatically shut down during the daytime.

Panel and APP Binding: Long press the configuration key on the top right corner to make it into the mode of distribution network through the APP instructions operation to do networking binding to a phone (mobile phone and panel to be discovered should be in the same LAN. In order to enter the next area setting it needs to bind the mobile APP first. Because the name of the lighting control needs to be edited in the phone before mapping in the panel.

 

Area Setting And Keypad Setting: Click the home page to enter into the lighting control center, select area Settings, select as XX area, and click “Ok” to save. (It needs to set all areas first before button setting of non-local control options)

Keypad Setting: The next step to select the interface key of the X key setting (How many keys needs to be control) selecting for control the lighting of local area or other areas (There is same options under the scene mode) . And then to select the icon of control light or scene mode of each keypad to click and edit the name for accepting the APP mapping, and then through the APP button options click edit key name to do the panel mapping. Click “OK” to save. (The steps of multiple keys’ setting and scene mode setting same as above.)

 

Luminous Indication and human body inductor setting:This function can be selectively turned on, turning on luminous Indication or human body inductor automatically lights up or both can be turned on at the same time.(screen brightness can be adjusted in the luminous mode, and human body induction mode. (Refer to the home key description).

 

Area Changed Setting: When the area is going to be changed, remove the area which need to be replaced from the area setting (Refer to the article 2 “Area Setting And Keypad Setting” ) no need to clearing the network.

 

Area Lock-in: When the panel was locked in local setting area, it cannot deploy its switch control in other areas. (The locked status will be displayed when deploying the area) but it can deploy the control permissions in other areas.

 

Mutual Exclusion Mode: In order to facilitate customer choice,select mutual exclusion mode when setting the scene mode.

 

Mutual Exclusion Of Control Area: For example: The fifth key of the local panel set as the comfortable mode and needs to enable Area 1: lamp one and lamp four, Area 2: lamp two and lamp four, Area 3: lamp two. When the scene mode overlays the lights of 3 areas, the lighting status is Area 1: lamp one and lamp three, Area 2: lamp one and lamp three, Area 3: lamp one, lamp two, lamp four will on when the scene mode is not turned on. Clicking on the comfortable mode status: Area 1: lamp one and lamp four, Area 2: lamp two and lamp four, Area 3: lamp two will on and the rest will be automatically turned off from on status. (this function will not affect other unrelated areas, and only the superimposed areas in scene mode will be mutual excluded. When the whole house mutual exclusion scene mode is turned on, the mutual exclusion area scene mode controls of the overlay area in scene mode which is not affected by it, and the lock area which is not controlled by it.)

 

Whole House Mutual Exclusion: When one of the panels has been setting as scene mode in the whole house and selected the whole house mutual exclusion, the light will on by the scene mode switching, All lights of whole house will be off if they are not in the scene mode. (this function sets that when an area of mutual Exclusion scene mode is on, it will be forced to extinguish or turn on its mode to control the light, lock-in area out of its control)

Non-mutual Exclusion Effect: Selecting the scene mode of this mode will not affect the setting of other areas to turn on and turn off, but will only turn on or turn off the lighting of the scene mode.

 

Single Key Control: When the local panel is connected to the loading conditions ( the device has four-way relay, maximum can connect four-channel.) When the light corresponding to the single key switch panel is on, and the panel display light on/off state

 

Scene mode: When the scene mode needs to set the lighting switching control of multiple areas at one time. It needs to do setting in the lighting control menu (Refer to the article 3 Keypad Setting) When mutual exclusion phenomenon occurs,it can select mutual exclusion in control area or whole house area.

Local Control: This area can control the four-way lighting loaded by the local panel when the area deploy is saved. The switch on-off state is fed back to the control center in real time. When the area has opened the one way or multi-way, the corresponding area of the control center will display its status (Refer to the control center article 2 “Home Key” )

 

Non-local Control: Click "Home" to enter "Light Control Center" and select the area to be deployed for non-local light switch operation, when it need to do area deploys for the non-local control in other places.

 

Scene mode: When it needs to embody the scene mode on the lighting control panel, the setting of lighting overlay is required. (except the fourth key or this key not under loading circumstance,the load of switch itself will not be turned on) Click "home" to enter into "scene Settings" to select the keys which need to be overlayed , and then select the lighting which need to be controlled from the local area or other areas. (Local areas will be displayed the difference between other areas). After selecting the lighting of local or other areas, go back and continue to select the areas which need to be superimposed. Click next to select scene mutual exclusion mode, the control areas mutual exclusion or whole house mutual exclusion options. After selecting, click “Ok”, and the setting of scene mode is completed. (Refer to the Lighting Control Mode Setting Steps And Function Settings article 7 “Mutual Exclusion Mode” )

Hot Products

ADAS DSM Driving AIDS Solution-ADAS Forward Collision Warning Lane Departure Warning(LDW) -When ...
86*92 LCD Touch Panel: Integrated the Control switch, background music, curtain control, and ...
◆ ± 16.5 kV air discharge mode ◆ ± 10.0 kV contact discharge mode ◆ 150pF/330Ω (IEC mode) ◆ AIO, ...
◆ ± 30.0kV air- and contact discharge ◆ 150pF/330Ω (IEC mode) ◆ AIO, Integrated high voltage source ...
◆ ±5.0kV direct output ◆ Repetition frequency:5kHz/100kHz option;Option:1Hz - 1MHz ◆ Voltage ...