LD-560 HbA1c Rapid Test Analyzer Big Capacity Fully Automatic HbA1c Analyzer

Country/Region china
City & Province shenzhen
Categories Switching Power Supply
InquireNow

Product Details

LD-560 HbA1c Rapid Test Analyzer Big Capacity Fully Automatic HbA1c Analyzer

 

Intended Use

The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications

ModelLD-560
MethodHPLC (High Performance Liquid Chromatography)
ParametersHbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional)
Test Speed90 seconds per test
Wavelength420nm
Sample TypeWhole Blood, Pre-diluted blood
Autoloader Capacity20 tubes
Reagents KitEluent A, Eluen B, Hemolysis, Chromatography Column
PrecisionCV<2%
Column Capacity3000 tests
Report Range3-18%
Working ConditionTemperature: 15-30℃, Humidity: 30-85%
Voltage100-240VA
Frequency50/60Hz
Dimensions378mm×380mm×510mm

 

Feature

  • Proven golden standard method for HbA1c testing
  • Large size touch  screen for friendly interface
  • Most cost-effective

PRINCIPLE
Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger. Glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin without being charged, and non-glycosylated hemoglobin has a positive charge. According to the different charged properties of hemoglobin, eluents with different pH values and ionic strengths are used sequentially, and several hemoglobin components including HbA1c are separated by high performance liquid chromatography. Each component is detected by a single-wavelength colorimeter, and the detected data is processed by a computer to calculate the percentage content of HbA1c in the total hemoglobin.

 

Performance Parameters
Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the test results should be within ±5%.
Repeatability: For samples with a test concentration of 4%-6%, the sample coefficient of variation (CV) of the test results is not greater than 2.0%.
Linear range: Within the range of 3%-18% of glycosylated hemoglobin, the linear correlation coefficient R value of the test results should not be less than 0.9900.
Stability: Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.

Certificated

 

 

Hot Products

LD-560 HbA1c Rapid Test Analyzer Big Capacity Fully Automatic HbA1c Analyzer Intended Use The Fully ...
HbA1c Analyzer Automated HbA1c Analyzer LD-500 Hematology Daignostic HbA1c Analyzer Intended Use LD...
HbA1c Analyzer Automated HbA1c Analyzer LD-500 Hematology Daignostic HbA1c Analyzer Intended Use LD...
HbA1c Test Analyzer LD-500 Automatic HbA1c Analyzer Intended Use LD-500 is an automatic instrument ...
HbA1c Analyzer Fully Automated HbA1c Analyzer LD-600 (HPLC) Intended Use The Fully Automated HbA1c ...
Hematology Analyzer Fully AutomatED HbA1c Analyzer LD-560 HbA1c Analyzer Intended Use The Fully ...