Home Companies Labnovation Technologies, Inc.

ISO Cov-19 Portable Antigen Rapid Test Device Saliva Test Kit Approved By KKM

Labnovation Technologies, Inc.
Active Member

Contact Us

[China] country

Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China

Contact name:Aimee li

Inquir Now

Labnovation Technologies, Inc.

ISO Cov-19 Portable Antigen Rapid Test Device Saliva Test Kit Approved By KKM

Country/Region china
City & Province shenzhen
Categories Other Consumer Electronics
InquireNow

Product Details

Rapid Test Kit Cov-19 Antigen Saliva Rapid Test Kit High Specificity 1 Test Professional Antigen Saliva Rapid Test Kit

Intend Use

SARS-CoV-2 antigen saliva rapid test kit is intended for detection SARS-CoV-2 antigen in human saliva sample. The test kit is an qualitative detection rapid test kit for professional use. About the test result, the positive result can be used forearly triage and rapid management of suspected populations, further nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative.
Product Details

ItemValue
NameSARS-CoV-2 Antigen Saliva Rapid Test Kit
Model NumberLX-401601
Type1 Tests/Kit
Warranty18 Months
Quality CertificationCE, MSDS
Safty StandardISO13485
Sample TypeSaliva
Sample volume3 Full drops
Test SpeedWithin 10-15 minutes
Specificity99.00%
Sensitivity94.29%
Total Accuracy >95%

 
Product  Advantage 

  • Short test time, read the result within 10-15 mins
  • Excellent performance, Strong Test line and Control line
  • Lower cost with high effciency
  • Reliable safety without extra instument
  • More comfortable, convenience and protable


 
 

 

 

 

 

 

 

 

Main Components

  • 1 Test Cassettes
  • 1 Saliva Collectors With Collection Tubes 
  • 1 Sample Extraction Buffer
  • 1 Instruction Manual

Use Step

  • Open the cap of the collection tube and istall saliva collector.
  • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
  • Screw the sample extraction buffer carefully.

  • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
  • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
  • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

 
 
Principle

  • This kit is an immunochromatography assay. According to the gold immunochromatographic test principle, double antibody sandwich method was used to detect SARS-CoV-2 nucleocapsid antigen in the samples. If there is antigen in the sample, complex can be formed at the detection line, and red band is shown, indicating negative result. If there is no antigen in the sample, complex cannot be formed at the detection line, and no red band is shown, indicating negative result.
  • Whether the sample contains antigen or not, the gold monoclonal antibody will bind to the enveloped antibody at the quality control line, form a compound and condense into a red band.

Application

  • Center for Disease Control and Prevention
  • Primary Health Care Institution
  • School
  • Prison / Detention Center etc.

Virus Sources

Global high frequency mutationAlpha / B.1.1.7(U.K.)Beta I B.1.351(South Africa)
Gemma I P.1(Brazil)Kappa I B.1.617.1(India)Delta I B.1.617.2(India)
C.37,ectAlpha I B.1.17(U.K.)B.1.36.16.etc
A.2.5,etcA.23.1Alpha I B.1.17(U.K.)
B.1.1.33.etcC.1.1.etc.etc.

Stroage And Expiry

Store as packaged in the sealed pouch at 2-30℃, avoid heat and sunshine, dry place, valid for 24 months. Do not freeze. Do not open the inner packaging until ready, it must be used within one hour if opened (Humidity≤60%, Temp: 20℃-30℃). Please use immediately when the humidity>60%.

Certificate

FAQ

  • MOQ

We have the MOQ limit, which is 10000 pieces.

  • Shipment

Air Cargo, Ocean Cargo or by Express

  • Payment

Business to Business  account

  • Contact

Whatsapp, E-mail or Phone.

  • Delivery Date

After order confirmed, we will arrange your order immediately,and offer you an estimated delivery date.

OEM Or ODM Accept

Yes, We accept OEM / ODM  order.

 

 

Hot Products

Rapid Antigen Saliva Rapid Test Kit CoV-19 Antigen Rapid Test Kit 20 Tests Professional Rapid Test ...
Rapid Antigen Test Kit CoV-19 Antigen Saliva Rapid Test Kit High Specificity 20 Tests Professional ...
Rapid Test Kit SARS-CoV-2 Antigen Saliva Rapid Test Saliva Sample Easy For Use Single Pack ...
Rapid Test Kit SARS-CoV-2 Antigen Saliva Rapid Test Kit High Accuracy 20 Tests Professional Use ...
Rapid Test Kit Cov-19 Antigen Saliva Rapid Test Kit High Specificity 1 Test Professional Antigen ...
Rapid Test Kit Antigen Salliva Rapid Test Kit 1 Test Single Pack Professional Testing Rapid Test Kit ...