HbA1c Analyzer LD-100 (PPOCT) Fully Automatic HbA1c Testing
Analyzer One Step Operation Analyzer
Intended Use
- It is one of the Labnovation HbA1c Testing Analyzer
- Intended for the content determination of hemoglobin A1c (HbA1c) in
human whole blood.
- Testing with 4μL sample,fast testing speed within 3min
- Color touch screen easy to click and read the results
- Protable and convience,suitable for the detection of HbA1c in
medical units at all levels.
Specifications
Model | LD-100 |
Measurement Time | < 3 minutes |
Sample Type | Whole blood |
Sample Volume | 4ul |
Data storage | 7000 |
Method | (Borate affinity)Fluorescent Immunoturbidimetry |
Operating Type | One-Step, fully automatic system |
Measurement Range | HbA1c 4.0~15%(NGSP Unit) eAG 68-385mg/dl(mmol/l) |
Operating Condition | Temperature:15~35℃ Humidity:15~80%R.H |
Storage Condition | Analyzer:10-60℃; Test kit: 2~8℃ |
Power connection | Detachable power supply cord |
Certificated | NGSP, IFCC |
![](http://img.everychina.com/nimg/6b/93/f8532b4cf8088a8580fd78dac430.jpg)
Basic Parameters
- Blood collection volume: The sampling volume of whole blood should
not be less than 4μl.
- Sample volume: 4μl full-blood.
- Analytical wave-length: 510nm and 580nm.
Analysis Interface
Click the Analysis button on the main interface to enter the sample
detection program. For details, see 5.3 Sample Detection
PRINCIPLE
- Uses the (borate affinity) fluorescent immunoturbidimetry
- Push a mixture containing a fluorescent borate conjugate into an
integrated test cup and mix to dissolve sufficiently.
- The blood samples in the sample collector are then pushed into the
buffer and mixed to release the hemoglobin from the red blood
cells.
- The total concentration of hemoglobin depends on the initial
reduced fluorescence signal.
- Fluorescent borate conjugates bind to glycosylated hemoglobin, and
glycosylated hemoglobin is determined by detecting the decrease of
fluorescent active ingredients.
- The percentage of glycosylated hemoglobin in total hemoglobin can
be determined.
Feature
- Simple Operation Step, One-Step Testing Process
- Protable, Light and Small,Easy to carry
- Working environment: Standard
- Battery Integrated
- Operating mode: Continuous
- High Accuracy
- RFID For Batch Management
- Color Touch Screen
- One Analyzer For HbA1c Testing
Reliable
IFCC calibrator | Normal | Abnormal | Normal | Abnormal |
Mean HbA1c% | 5.4 | 9.6 | 5.3 | 9.2 |
CV (%) | 2.5% | 1.9% | 2.4% | 1.8% |
Use Step
- Place cartridge in analyzer
- Push bead into reagents
- Insert sample into cartridge
![](http://img.everychina.com/nimg/b1/61/a361161d7880cb79c913e174e5a0.jpg)
Performance Indicators
- Accuracy: tested with the reference material as samples, and the
relative deviation of the determination results of the analyzer
should be within the range of ±8%.
- Precision: Samples with a concentration of 4.0%-6.5% are detected, and the
sample coefficient of variation (CV) of the test results is
within 3%.
- Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient
r of the test results should be no less than 0.9900.
- Stability:Within 8 hours after the instrument is turned on and stable, the
same normal sample is tested, and the relative deviation of the
test results is not more than ±3%.
- Permission: The authority is the first-level authority, and the login
authority is the first-level authority.
Certificated
![](http://img.everychina.com/nimg/90/f1/a61b93b1aab74b40f95f08968368.jpg)