Glc Gas Liquid Chromatography Equipment Apparatus Heating 40C Min

Country/Region china
City & Province wuxi jiangsu
Categories Physical Measuring Instruments
InquireNow

Product Details

Universal gas chromatograph GC-7890

 

The GC-7890 gas chromatograph is a new generation of network laboratory gas chromatograph. microcomputer controlled and large-screen display, the newly designed keyboard keys are simple and fast, the circuits are all imported components, features stable and the high reliability.

 

Technical specifications

Column oven
Temperature rangeroom temperature +5~420℃
Temperature setting1˚C; programmed ramp rate 0.1˚C
Heating rate40˚C/min
Temperature Stability0.01˚C when ambient temperature changes by 1˚C
Program temperature10 steps temperature program adjustable
InjectorVarious inlets are available, packed column inlet, split/splitless capillary inlet

 

Detection parameters
Hydrogen flame ionization detector (FID)
Control temperature: 400℃
Detection limit: ≤5×10-12g/s (n-hexadecane)
Drift: ≤5×10-13A/30min
Noise: ≤2×10-13A
Dynamic linear range: ≥107
Thermal Conductivity Cell Detector (TCD)
Control temperature: 400℃
Sensitivity: ≥10000mv.ml/mg (n-hexadecane)
Drift: ≤100uV/30mi
Noise: ≤20uA
Dynamic linear range: ≥105
Electron Capture Detector (ECD)
Control temperature: 350℃
Detection limit: ≤1×10-14 g/ml (γ-666)
Drift: ≤50uV/30min
Noise: ≤20uV
Dynamic linear range: ≥104
Flame Photometric Detector (FPD)
Control temperature: 400℃
Detection limit: ≤1×10-12g/s(P) ≤1×10-12g/s(S)
Drift: ≤4×10-11A/30min
Noise: ≤2×10-12A
Dynamic linear range: ≥103(P) ≥102(S)
Nitrogen Phosphorus Detector (NPD)
Control temperature: 400℃
Detection limit: ≤5×10-13g/s(P) ≤5×10-13g/s(N)
Drift: ≤25×10-12A/30min
Noise: ≤4×10-13A
Dynamic linear range: ≥103 (P)
Dimensions: 465*460*550mm, whole machine weight: 50kg,
Input power: AC220V 50HZ Power: 2500w

 

Hot Products

BSC-IIB2 Biological safety cabinet The introduction of BSC-IIB2 Biological safety cabinet: ◆ ...
Benchtop biosafety cabinet The introduction of Benchtop biosafety cabinet: ◆ Secondary biosafety ...
BHC-1300ⅡA2 Biosafety cabinet The introduction of BHC-1300ⅡA2 Biosafety cabinet: ◆ The biosafety ...
BHC-1300IIB2 Biosafety cabinet The introduction of BHC-1300IIB2 Biosafety cabinet: ◆ The biosafety ...
Universal gas chromatograph GC-7890 The GC-7890 gas chromatograph is a new generation of network ...
Universal Gas Chromatograph touch screen operation network connection This gas chromatograph can ...