Pump station FJ-700F, Air cooling with RVP-6 and ZDF-11A2

FJ-700 F standard Turbo Molecular Pump Unit is an cleaning equipment to obtain high vacuum.
Such equipment is a vacuum obtaining system adopting the principle of vacuum, and consists of mechanical pump and molecular pump. It is featured by quick starting, high vacuum, few oil pollution, easy operation and etc and widely used in the fields of surface analysis, accelerator technology, plasma technology, electric vacuum device manufacturing and other vacuum areas. The equipment is specifically composed of non-standard frame,mechanical pump and pipelines, electrical control systems, water
cooling protection control and etc.

 

Configuration:

NameNumber
FF-160/700F molecular pump and power supply1
RVP-6 mechanical pump1
Frame1
Control power supply1
ZDF-11A2 combination vacuum gauge1
Other attachments 

 

Features:

1. Quick starting

2. High vacuum

3. Less oil pollution

4. Easy operation

5. Wide application

 

Specifications: 

 UnitFJ-700
Flange(In) DN160 CF
DN160 ISO-K
Flange(Out)ISO-KFDN40
Pumping Speedl/sN2:700
He:580
H2:260
Ar:680
Compression Ratio N2:109
He:107
H2:106
Ar:109
Ultimate PressurePaCF:6×10-8
ISO-K:6×10-7
recommended forevacuum pressurePa100
forevacuum pump RVP-6( default )
Cooling Type,Standard 

Air

Cooling Water ConsumpyionL/min>1
Cooling Water Temperature≤25
Input voltage/ frequencyV/Hz380±20/50
Environment temperature (℃)Water cooling5℃-40℃
  
mounting position Vertical
Controller Model FD-ⅡB/TCDP-Ⅱ
L*W*Hmm550×690×850(water)
  
Weightkg135

 

Maintenance:

1. Routine maintenance:
During the daily use of the equipment, pay attention to observing the vacuum pump’s oil level and the pump oil color; if the oil is lacking, supply it in time. If the pump oil color is abnormal, change it in time.


2. Maintenance during the running:
During running of the equipment, pay attention to maintain the pumped vacuum chamber clean, so as to avoid the debris entering into the vacuum chamber and cause the damage of the equipment.

Hot Products

Power supply & Controller , TCP-100 , Instrumental pumps, compact TCP-100 molecular pump control ...
Pump station FJ-700F, Air cooling with RVP-6 and ZDF-11A2 FJ-700 F standard Turbo Molecular Pump ...
Pump station FJ-620 Water Cooling with Pre-vacuum and Vacuum guage FJ-620 E standard Turbo Molecular ...
Pump station FJ-110, Water cooling , Ultimate vacuum (no load): ≤ 9E-5Pa FJ-110 Sandard Turbo ...
Pump station FJ-700 , water cooling with Mechanical pump and Vacuum guages FJ-700 E standard Turbo ...
Pump station FJ-80, Compact oil or dry backup pump optional The turbo pumping station is a piece of ...