Home Companies Beijing Cable Industry Development Co.,Ltd

5 Core 450V XLPE Insulated PVC Sheathed Cable Low Voltage For Construction

Beijing Cable Industry Development Co.,Ltd

Contact Us

[China] country

Trade Verify

Contact name:

Inquir Now

Beijing Cable Industry Development Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

5 Core 450V XLPE Insulated PVC Sheathed Cable Low Voltage For Construction

Country/Region china
Categories Power Cables
InquireNow

Product Details

 

 

Applicable to the cables and wires of rated yolatage 450/750V and less than 450/750V AC for power

plant, householdelectrical applance,insurment and telecommunication equipment,Copper armoured cable 4 core 25mm 35mm has excellent chemical corrosion resistance, but also has the properties of flame retardant and non water-absorption and suitable for underground installation, which can withstand certain mechanical pressure,but can’t withstand mechanical tension.

 

Construre :

1. Conductors: copper or aluminum.

2. Both armored and non-armored type power cables are available.

3. Voltage rating: 0.6/1kV 3.6/6kV 6/10kV 8.7/15kV 26/35kV.

4. PVC or XLPE sheathed.

5. Number of cable cores: one core (Single core),two cores (Double cores),three cores,

Four cores (Four Equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),

Five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).

6. Standards: IEC 60502.IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. Or other special characteristics as customers request.

 

Low voltage copper conductor one core to five cores XLPE Electrical Cable

 

TypeDesignationOperating Performance
YJVCopper conductor,XLPE insulated,PVC sheathed power cable

1). Rated power frequency voltage Uo/U: 0.6/1KV.
2). Max. Permissible continuous operating temperature of conductor: 90℃
3). Max. Short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 250℃

4). The ambient temperature under installation should not below 0℃
5). The bending radius of a cable should not be less than 15 times of the cable diameter.

6). The test voltage (A.C.): 3.5kV/5min.

7). The flame-retardant properties of cable comply with grade A, B, C of GB/T19666-2005 or IEC60332.

YJLVAluminum conductor,XLPE insulated,PVC sheathed power cable
YJYCopper conductor, XLPE insulated,PE sheathed power cable
YJLYAluminum conductor, XLPE insulated,PE sheathed power cable
YJV22Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable 
YJLV22Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable
YJV23Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJLV23Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJV32Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable 
YJLV32Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable
YJV33Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
YJLV33Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable

 

 

Low voltage copper conductor one core to five cores XLPE Electrical Cable 

 

Hot Products

Spiral cable with outer PUR sheath ,unshielded, UL&cUL Certificated, 80℃ 30V Construction Conductor ...
Spiral cable with outer PUR sheath ,unshielded, UL&cUL Certificated, 80℃ 300V Construction Conductor ...
Spiral cable with outer TPE sheath ,UL&cUL Certificated, unshielded Construction Conductor : ...
Spiral cable with outer PUR sheath ,shielded, UL&cUL Certificated, 80℃ 600V OR 1000V Construction ...
Applicable to the cables and wires of rated yolatage 450/750V and less than 450/750V AC for power ...
3×50mm2 3×70mm2 8.7/15kV PVC Sheathed XLPE Power Cables Applications: Used for Power transmission ...