CE certificated Single Phase 220v Vector Variable Frequency Inverter 1hp 2hp 3hp For Oil Field


 


Technical characteristics

Drive motor type:Ac asynchronous motor, Ac permanent magnet synchronous motor
Four control modes:PG vector control(FVC), PG-free vector control(SVC),
V / F control, Torque control
Speed control range:PG vector control(FVC)1:1000
PG- free vector control(SVC)1:200
V / F control 1:50
Speed control accuracy:PG vector control (FVC)±0.2%
PG- free vector control (SVC)±0.5%
Starting torque:PG vector control(FVC):180 % rated torque/0.01Hz
PG- free vector control (SVC)150% rated torque/0.25Hz
Torque control accuracy:PG vector control (FVC)±5%
PG- free vector control (SVC)±8%
Multi-motor switching: Two groups of motor parameters can realize the switching control of the two motors.
Motor overheating protection:Optional IO expansion card, analog A / 3 can accept input from the motor temperature sensor
Supports multiple encoders:Supports differential, open collector, uvw, rotary transformer, sine and cosine encoder
Torque limitation and control: the "excavator" feature, automatically limits the torque during operation to prevent frequent overcurrent trips. Closed-loop mode can realize torque control.


Products Specifications:

 

Basic FunctionSpecification
Maximum output frequency0~500Hz
Carrier frequency0.5kHz~16.0kHz;According to the load characteristics, carrier
frequency can be adjusted automatically
Input frequencyRange :47~63Hz
Control modeV/F Open/closed loop vector control(SVC/FVC)
Speed range1:50(Vector mode 0 ) 1Hz/150% rated torque
Overload capabilityG type:150% rated current for 60s;
180% rated current for 3s
P type:120% rated current for 60s;
150% rated current for 3s
Torque boostAuto Torque boost Manual Torque boost; 0.1%~30.0%.
V/F curve V/FFour modes : Line , Multi-point , Square V/F curve, V/F separation
Jog controlJog frequency range:0.00Hz to F0-10(Max frequency)
Accelerate/Decelerate curveLine or S-curve Acc/Dec mode, four kinds of Acc/Dec time Range
of Acc/Dec Time0.0~65000.00s.
DC brakeDC brake frequency: 0.00Hz to Maximum frequency
brake time: 0.0 to 36.0s
brake current value: 0.0 to 100%
Simple PLC, Multi-speed16-speed operating through built-in PLC or control terminal
Built-in PIDClose loop control system can be formed easily by using PID
Automatic voltage
regulating (AVR)
Output voltage is regulated when voltage of the power network changes
Overvoltage and over current
stall control
During operation automatically limits the inverter output current
and bus voltage, to prevent fan over current and overvoltage trip.
Rapid current limiting
function
Minimizing flow failures, protect the normal operation of the inverter
Instantaneous stop non-stopLoad feedback energy compensation voltage is reduced and continues to maintain a short time when change is momentarily interrupted.
Speed tracking startFor high-speed rotation of the motor speed identification, impact-
free smooth start
Rapid current limitRapid software and hardware limiting technology to avoid
frequent converter over current fault.
Virtual IOFive sets of virtual DO, five sets of virtual DI, enables easy logic control.
Timing ControlTiming control: set the time range 0.0Min~6500.0Hour
Multi-motor
switch
Two independent motor parameters, enabling two motors switching control
Bus SupportTwo independent Modbus communication, CAN-Link
Command sourceGiven the control panel, control terminal, serial communication port given. It
can be switched by a variety of ways.
Torque boostAuto Torque boost Manual Torque boost ; 0.1%~30.0%.
Frequency sourceNine kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways.
Auxiliary
frequency source
Nine kinds of auxiliary frequency source. Flexible implementation of auxiliary
frequency tuning, frequency synthesis.
Input terminalSix digital input terminals, one only supports 50khz high pulse input
Two analog input terminals, one support 0V~10V voltage input
One support 0 ~ 10V voltage input or 0 ~ 20mA current input
Output
terminal
One high-speed pulse output terminal (optional open collector type), support of
square wave 0 ~ 50kHz signal output
One digital output terminal
One relay output terminals
Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V
voltage output
Display and operation
LED displayDisplay parameters and status information
The key lock and function selectionAchieve some or all of the keys locked, scope definition section keys
to prevent misuse.
Protection functionInput/output phase failure protection ,Overcurrent protection ;Over
voltage protection; Undervoltage protection; Overheat protection ;
Overload protection
OptionsBrake assembly, PG card
Environment
Application environmentIn-door, free from direct sunlight, dust , corrosive gas, combustible gas, oil mist , steam , water drop and salt .
AltitudeLower than 1000m
VibrationLess than 5.9m/s(0.6g)


Benefits of VFD

Energy Savings with Variable Speed Drives

If you have an AC motor-driven application that does not need to be run at full speed, then you can cut down energy costs by controlling the motor with a Variable Speed Drive (VSD). Variable Speed Drives (Also known as Variable Frequency Drives) allow you to match the speed of the motor-driven equipment to the process requirement.

Variable Torque Versus Constant Torque

Variable speed drives, and the loads they are applied to, can generally be divided into two groups: constant torque and variable torque. The energy savings potential of variable torque applications is much greater than that of constant torque applications. Variable torque loads include centrifugal pumps and fans, which make up the majority of HVAC applications. Constant torque loads include vibrating conveyors, punch presses, rock crushers, machine tools, and other applications where the drive follows a constant V/Hz ratio.

Why Variable Torque Loads Offer Great Energy Savings

In variable torque applications, the torque required varies roughly with the square of the speed, and the horsepower required varies approximately with the cube of the speed, resulting in a large reduction of horsepower for even a small reduction in speed. A motor in a variable torque application will consume only 25% as much energy at 50% speed as it will at 100% speed. This is referred to as the Affinity Laws, which define the relationships between speed, flow, torque, and horsepower.

Energy Consumption

Variable Speed Drives (VSDs) allow you to consume less energy than other speed control techniques when load requirements are less than full speed, as is usually the case in HVAC applications.

 

 

Factory tour:



 


 

Hot Products

220V single phase input VFD frequency converter 0.75kw 1hp For Fire Water supply Power class and ...
220V single phase input VFD frequency converter 0.75kw 1hp For food processing machine Power class ...
CE certificated Single Phase 220v Vector Variable Frequency Inverter 1hp 2hp 3hp For Oil Field ...
FPR High-performance closed-loop vector converter Power class Single-phase 220v±15% 0.4-2.2kw Three...
Made In China 3 phases Mini-Series 2hp 1.5kw VFD For Rubber Cutting Machine Product introduction ...
DIN Rail CE Certificated 3 phases Mini-Series 2hp 2.2kw VFD For Water Treatment Product introduction ...