45KW 60 Hp VFD Electronic Variable Frequency Drive For Ventilation Fan Speed Control

CHIFON ELECTRIC CO.,LIMITED
Active Member

Contact Us

[China] country

Address: No. 25 Xianxing Rd, Xianlin Industrial Park, Hangzhou, Zhejiang, China

Contact name:Molly

Inquir Now

CHIFON ELECTRIC CO.,LIMITED

45KW 60 Hp VFD Electronic Variable Frequency Drive For Ventilation Fan Speed Control

Country/Region china
City & Province hangzhou zhejiang
InquireNow

Product Details

 

V/F Control Low Voltage 37KW 3Phase VFD Inverter For Fire Water Supply


 

 

Product Functions:

 

Basic FunctionSpecification
Maximum output frequency0~500Hz
Carrier frequency0.5kHz~16.0kHz;According to the load characteristics, carrier
frequency can be adjusted automatically
Input frequencyRange :47~63Hz
Control modeV/F Open/closed loop vector control(SVC/FVC)
Speed range1:50(Vector mode 0 ) 1Hz/150% rated torque
Overload capability

G type:150% rated current for 60s;

180% rated current for 3s
P type:120% rated current for 60s;

150% rated current for 3s

Torque boostAuto Torque boost Manual Torque boost; 0.1%~30.0%.
V/F curve V/FFour modes : Line , Multi-point , Square V/F curve, V/F separation
Jog controlJog frequency range:0.00Hz to F0-10(Max frequency)
Accelerate/Decelerate curveLine or S-curve Acc/Dec mode, four kinds of Acc/Dec time Range
of Acc/Dec Time0.0~65000.00s.
DC brakeDC brake frequency: 0.00Hz to Maximum frequency
brake time: 0.0 to 36.0s
brake current value: 0.0 to 100%
Simple PLC, Multi-speed16-speed operating through built-in PLC or control terminal
Built-in PIDClose loop control system can be formed easily by using PID
Automatic voltage
regulating (AVR)
Output voltage is regulated when voltage of the power network changes
Overvoltage and over current
stall control
During operation automatically limits the inverter output current
and bus voltage, to prevent fan over current and overvoltage trip.
Rapid current limiting
function
Minimizing flow failures, protect the normal operation of the inverter
Instantaneous stop non-stopLoad feedback energy compensation voltage is reduced and continues to maintain a short time when change is momentarily interrupted.
Speed tracking startFor high-speed rotation of the motor speed identification, impact-
free smooth start
Rapid current limitRapid software and hardware limiting technology to avoid
frequent converter over current fault.
Virtual IOFive sets of virtual DO, five sets of virtual DI, enables easy logic control.
Timing ControlTiming control: set the time range 0.0Min~6500.0Hour
Multi-motor
switch
Two independent motor parameters, enabling two motors switching control
Bus SupportTwo independent Modbus communication, CAN-Link
Command sourceGiven the control panel, control terminal, serial communication port given. It
can be switched by a variety of ways.
Torque boostAuto Torque boost Manual Torque boost ; 0.1%~30.0%.
Frequency sourceNine kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways.
Auxiliary
frequency source
Nine kinds of auxiliary frequency source. Flexible implementation of auxiliary
frequency tuning, frequency synthesis.
Input terminalSix digital input terminals, one only supports 50khz high pulse input
Two analog input terminals, one support 0V~10V voltage input
One support 0 ~ 10V voltage input or 0 ~ 20mA current input
Output
terminal
One high-speed pulse output terminal (optional open collector type), support of
square wave 0 ~ 50kHz signal output
One digital output terminal
One relay output terminals
Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V
voltage output
Display and operation
LED displayDisplay parameters and status information

The key lock and function selection

 

Achieve some or all of the keys locked, scope definition section keys
to prevent misuse.
Protection functionInput/output phase failure protection ,Overcurrent protection ;Over
voltage protection; Undervoltage protection; Overheat protection ;
Overload protection
OptionsBrake assembly, PG card
Environment
Application environmentIn-door, free from direct sunlight, dust , corrosive gas, combustible gas, oil mist , steam , water drop and salt .
AltitudeLower than 1000m
VibrationLess than 5.9m/s(0.6g)

 

 

Drive specifications:

Full Load Amps (FLA)

The process of sizing a VFD starts with the motor’s full load amps.

Match your motor’s FLA with the amp ratings of each VFD you consider. Or play it safe and get a VFD with a higher amp rating than your motor requires to give yourself a bit of cushion for constant torque loads and/or applications that require more strength during start up. If you don’t get a big enough drive, it will trip out every time you try to power up.

Horsepower (HP)

​Load or motor horsepower is a great way to refine your search for drives fit for your application, but it shouldn’t be used as a direct reference for drive requirements. Due to variables in load requirements like RPM (a 900 RPM motor has a much different amp requirement than a 3600 RPM motor), sizing a VFD on HP alone will likely get you in trouble. We strongly recommend you use HP to narrow your selection but that you use amps (FLA) to determine the right VFD for your motor.

Voltage and Phase

You have to match the voltage of the VFD and motor to your available voltage on site. For low-voltage applications in the U.S., this is usually 208, 230 or 460 VAC. For medium voltage (1000 volts to 35kV) or other applications, it’s wise to call application specialists or engineers for assistance.

VFDs are primarily used in industrial facilities with three-phase power supply. A VFD can act as a phase converter if you have a three-phase motor but are limited to one-phase supply.

If your load is 3-horsepower or below (approx. <10 amps FLA), there are several single-phase input drives to consider. If your motor is greater than 3 HP, you could use a drive built for three-phase input so long as it has been de-rated correctly.

To properly de-rate your VFD to act as a phase converter for one-phase incoming power, start with your motors FLA. Multiply the motor FLA by two and select a VFD rated for twice the motor’s FLA. For example, if you have a 10 HP motor with a FLA of 28 amps, you’ll need a VFD rated more than 56 amps and around 20 HP.

For small shops or home use, keep in mind that VFDs are the number one power polluters on the planet. They pollute power quality even more when used as a phase converter. Talk to your sales engineer to see if using a line reactor is the right option for you.

Application (Constant or Variable Torque)

Now let’s consider the work you’re doing. Do you need to run a pump, rotary kiln or an extruder? The answer will determine whether you need a variable or constant torque drive.

Variable torque drives are for simple centrifugal equipment like fans and pumps. These drives allow the motor to apply only the torque necessary to run the application at slower speeds. Centrifugal applications rarely exceed the rated current, so variable torque drives only need a one-minute overload current capacity of 120%.

Constant torque VFDs are necessary for heavier applications that require continuous torque at all speeds like conveyors, positive displacement pumps, punch presses and extruders. For example, a conveyor runs constantly, but it needs more power as weight is added to the belt, so your drive has to be able to handle the difference. That’s why constant torque drives need at least 150% one-minute overload current capacity to protect against load spikes.

You may think, let’s play it safe and go with constant torque even for a basic fan application. And if you absolutely can’t live without that fan, it could be a worthwhile precaution. But that’s like buying a sports car for your grandma — you’re spending a lot of money on performance that will never get used.

Speed Range

VFDs can under and over speed motors. A VFD can run your motor slow enough that its internal cooling fan isn’t moving enough air to keep the motor operational. Proper precautions should be implemented to protect your motor, such as use of a separate auxiliary cooling fan, if you plan to under speed your motor.

A VFD also can operate the motor faster than its nameplated RPM value. However, be advised that in doing so you will lose torque. We recommend you don’t go more than 20% above a motor‘s rated speed and that you check with your motor manufacturer before doing this to make sure over-speeding won’t void any warranties.

Control Method

When buying a VFD, you’ll want to think through your method of control. Will you be controlling the VFD from a door mounted keypad or from a PLC?

Many manufacturers require Ethernet communications to get the right information from their drives to the PLC and production automation systems. More operations are moving to these advanced communication systems, but some inexpensive drives don’t include these options. So if you’re looking to advance your systems in the future, make sure you’re getting drives that won’t hold you back. Your sales engineer will be able to help you select the correct communication protocol based on your needs and preferences.

 

 

 


 

Hot Products

Self Patented VSD Pump Control 4kw 220V single phase input 380v three phase ►Products Features: 1, ...
FPR High-performance closed-loop vector converter Power class Single-phase 220v±15% 0.4-2.2kw Three...
FPR High-performance closed-loop vector converter Power class Single-phase 220v±15% 0.4-2.2kw Three...
132kw Forced Convection Variable Speed Drive VFD 380V 3 Phase For Foaming Machine What is a Variable ...
V/F Control Low Voltage 37KW 3Phase VFD Inverter For Fire Water Supply Product Functions: Basic ...
FPR500A Series Vector Variable Frequency Inverter For Fan Single Phase Motor 2.2kw Power class ...