Home Companies Wuhan Green Song Zheng Cable Co.,Ltd

PE XLPE High Temperature Multi Conductor Cable 6kV 300 Sqmm Aluminium Material

Wuhan Green Song Zheng Cable Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Room 1 Floor 1 Wire and Cable Manufacturing Bare Wire Workshop 1 Wujin Industrial Park, Dongjing Street, Hannan District, Wuhan City

Contact name:Bill Li

Inquir Now

Wuhan Green Song Zheng Cable Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

PE XLPE High Temperature Multi Conductor Cable 6kV 300 Sqmm Aluminium Material

Country/Region china
City & Province wuhan
Categories Power Cables
InquireNow

Product Details

Aluminum core XLPE insulation, PE sheath cable 6kV~35kV (YJLY)

1. Application

This product is suitable for power lines with rated voltage of 0.6 / 1kV and below, for power transmission, suitable for laying in hotels, stations, airports, high-rise buildings, chemical industry, petroleum platform, power station, subway, tunnel and other fixed laying places.

2. Cable Performance

The long-term allowable operating temperature of the cable shall not exceed 90℃, and the short-time operating temperature shall not be over 250℃.

The ambient temperature of the installation should not be lower than 0℃.

Minimum bending radius during cable installation: single-core cable not exceeding 15D (D is cable diameter), multi-core cable not exceeding 12D (D is cable diameter)

3. Cable construction

3.1 Conductors adopts compact fan or round structure, YJV 32 and YJY 33 are copper conductors, and YJLV32 and YJLY33 are aluminum conductors.

3.2 Cross-linked polyethylene insulation material is used, and the insulation thickness is shown in Table 1.

Table 1

Nominal section mm2Nominal thickness of the insulation is mmNominal section mm2Nominal thickness of the insulation is mm
1.5 2.50.71201.2
4 60.71501.4
10 160.71851.6
25 350.92401.7
501.03001.8
70 951.14002.0

3.3 Cable armored material: galvanized steel wire is used, and the single core cable used for AC system adopts non-magnetic armored material.

3.4 YJV 32 and YJLV32 cable sheath adopt 90℃ PVC sheath, and Y JY33 and YJLY33 cable sheath use 90℃ polyethylene sheath.

3.5 Low smoke halogen-free flame retardant cable, sheath material made of flame retardant polyolefin sheath material, cable model and name are shown in Table 2.

Table 2

Factory Codename
YJ V 32Copper core crosslinked polyethylene insulated steel wire armored with PVC sheathed cable
YJ V 33Copper core cross-linked polyethylene insulated steel wire armored with polyethylene sheathed cable
YJL V 32Aluminum core xLPE insulated steel wire armored with PVC sheathed cable
YJL V 33Aluminum core crosslinked polyethylene insulated steel wire armored with polyethylene sheathed cable
WDZ(A,B,C)-YJY33Copper core crosslinked polyethylene insulated steel wire armored with polyolefin sheath flame retardant (A, B, C) cable
WDZ(A,B,C)-YJLY33Aluminum core cross-linked polyethylene insulated steel wire armored with polyolefin sheath flame retardant (A, B, C) cable

3.6 Nominal outer diameter and weight

Table 3

specifications

Core * section

Nominal outer diameter mm

Nominal weight

kg / km

specifications

Core * section

Nominal outer diameter mmNominal weight kg / km

YJV32

YJY33

YJLV32

YJLY33

YJV32

YJY33

YJLV32

YJLY33

1*1.510.62152062*1.513.4334315
1*2.511.02362212*2.514.2380349
1*411.52642402*415.1440391
1*612.02972612*617.1626555
1*1013.03643042*1019.1793671
1*1614.04473512*1621.1992798
1*2515.65814292*2525.014561149
1*3517.38146042*3526.617171293
1*5018.89847002*5029.821271553
1*7020.712468362*7034.730512223
1*9523.0167611062*9538.538232672
1*12024.6197012522*12042.045373086
1*15026.6232114292*15047.357963995
1*18528.7275316392*18552.069424692
1*24031.8342819512*24057.185165533
1*30035.2435625002*30062.6102576508
1*40039.2537530072*40069.7125847801
3*1.513.83713434*1.514.6384221
3*2.514.74283824*2.515.5454255
3*415.75044314*417.6658298
3*617.77166084*618.8782350
3*1020.09247424*1021.31038454
3*1622.111808904*1624.41487579
3*2526.3174712864*2528.32039796
3*3528.1209914634*3530.52497954
3*5031.5263417734*5035.634461219
3*7037.2382825864*7041.045631648
3*9540.9480130734*9544.657692473
3*12044.6574935734*12050.874802976
3*15050.6737646754*15056.590403697
3*18555.9888655114*18561.7109114416
3*24061.91109366184*24068.4136735467
3*30067.41331976954*30074.5165186563
3*40076.417288101134*40084.4215178162
3*2.5+1*1.515.34654093*2.5+2*1.516.9618553
3*4+1*2.517.36715813*4+2*2.518.1731625
3*6+1*418.57946573*6+2*419.4873711
3*10+1*620.910278063*10+2*622.01137878
3*16+1*1023.8145210983*16+2*1025.116111195
3*25+1*1626.7189913523*25+2*1627.720921447
3*35+1*1628.9229315593*35+2*1630.225121680
3*50+1*2532.8293719283*50+2*2536.036272468
3*70+1*3538.3410227743*70+2*3540.246513011
3*95+1*5042.4523433283*95+2*5044.759443639
3*120+1*7048.2681044013*120+2*7051.878714928
3*150+1*7052.1793449933*150+2*7055.289725487
3*185+1*9557.6973359473*185+2*9560.9110776561
3*240+1*12063.71208471303*240+2*12067.0136157779
3*300+1*15069.71461583363*300+2*15073.4164919133
3*400+1*18579.218991110033*400+2*18583.22136511940
4*2.5+1*1.517.16345625*1.515.3455408
4*4+1*2.518.37536385*2.517.3656579
4*6+1*419.79017275*418.6782658
4*10+1*623.1130910275*620.0936749
4*16+1*1025.6169112395*1023.713791073
4*25+1*1629.2226015635*1626.618031314
4*35+1*1631.6276418175*2532.427181970
4*50+1*2537.3391526195*3534.733282268
4*70+1*3542.1508532525*5039.042702837
3*95+1*5048.2697843825*7045.960213994
4*120+1*7053.6849252445*9550.576534767
4*150+1*7058.2997660045*12056.292495696
4*185+1*9564.21222271615*15061.9111246666
4*240+1*12070.61513085325*18567.5134297825
4*300+1*15079.119314109885*24076.31764610287
3*400+1*18587.923805131255*30083.12129312001
    5*40092.62629014489

 

4. Main performance

4.1 The DC resistance of 20℃ conductor shall meet the requirements of Table 3.

Table 3

nominal cross mm21.52.5461016253550
20℃ conductor DC resistance is not over (Ω / km)copper12.17.414.613.081.831.170.7270.5270.387
aluminium 12.47.414.613.081.911.200.8680.641
nominal cross mm27095120150185240300400 
20℃ conductor DC resistance is not over (Ω / km)copper0.2680.1930.1530.1240.09910.07540.06010.0470 
aluminium0.4430.3200.2530.2060.1640.1250.1000.0778 

4.2 Finished cable shall be subjected to 3.5kV / 5min voltage test without breakdown.

 

Hot Products

Cross-sectional Area 1.5mm2 to 1000mm2 XLPE Insulated Power Cable with Max. Operating Temperature 90...
XLPE Insulated Fire Resistant IEC 60332-1 Power Cable with Max. Short-circuit Temperature of 250℃ ...
Aluminum core XLPE insulation, PE sheath cable 6kV~35kV (YJLY) 1. Application This product is ...
Aluminum core XLPE insulation, PE sheath cable 6kV~35kV (YJLY) 1. Application This product is ...
Aluminum core XLPE insulation, PE sheath cable 6kV~35kV (YJLY) 1. Application This product is ...
Aluminum core XLPE insulation, PE sheath cable 6kV~35kV (YJLY) 1. Application This product is ...