Open channel flowmeter, ultrasonic flow meters for waste water flow
measurement, remote converter
Technical data:
- Type : Ultrasonic Open Channel Flowmeter
- Medium : Clarified Water
- Pressure : Atmospheric
- Temperature : 0 ~ 500 C
- Humidity : 95%
- Channel Depth : 1.1 meters
- Suspended Solids : <65 milligrams / liter
- Level Measurement Range : 4 meters
- Resolution : 1mm
- Measuring Error : ± 0.2%
- Temperature Compensation : Built in
- Type : 2 Wire Loop
- Power Supply : 24 VDC
- Output : 4 ~ 20 mA DC
- Display : LCD
- Flow Linearization : Required
- Table Entry : Local Key Pad
- Housing : Aluminum, Epoxy Coated
- Ingress Protection : IP67
- Sensor Material : PVDF
- Process Connection : 1.5" NPT ANSI B 1.20.1 Threaded
- Beam Angle : 120
- Cable Entry : 0.5" NPT ANSI B1.20.1
- Locking Nut : Required
The main function characteristics:
- With a fully independent intellectual property rights.
- Has wide range of temperature compensation and original ERD
interference intelligent identification system, measurement data
stability, high precision.
- Six groups flow condition all data sending 485 serial ports
output, PC directly receive, decimal shows, the convenient user
record and read archived.
- Original "fluid flow correction system" that flow coefficient
according to slot size and level to be automatic operation weir and
timing compensation.
- The blackout time time, the year/month/day/when/points/SEC,
flow data, using the ferroelectric double backup storage 10 years
off.
- Original "measuring tank jam recognition alarm system" can
detect liquid slag quality measurement slot throat and obstruction
caused by measurement.
- Precise date determined when the calendar clock Settings,
display and cooperate with the memo and time axis to file
information records.
- Has 4~20 mA three wire system, RS485, switch quantity and so
on many kinds of signal output function selection.
- Using intelligent measuring high, digital calibration, the
user installation calibration simple and quick.
- The ultrasonic non-contact measurement with no moving parts,
flow without components within, no block sensor fault hidden
trouble.
Technical parameters
- Applicable weir: Right angled triangle weir:The size of the
opening 500mm
- Rectangular weir:The size of the opening
250mm,500mm,750mm,1000mm
- Bashir slot: Larynx way width: 25mm,51mm,76mm,152mm,228mm
- Flow range:according to weir/flume size
- Function characteris tics: data storage 1 year, can be
arbitrary time of the inquiry
- Flow precision: 1~5% F·S
- Level range:2m
- Level precision:±0.25% F·S (at times, and the blind process
℃)
- Probe blind area:≤300mm (at 25 ℃)
- Output signal:4~20 mA +RS485
- Showing the way:16 LCD display,
- Among them:Four level height,Four transient flow,Eight of the
accumulative total flow,16 the calendar clock (buttons when)
- Working temperature:-10~60℃(default),can be customized of
level: 0~80℃
- Work power:AC220V/50Hz,or DC24V/300m
- Outlet way: instrument standard plugs, Liquid level meter
quick connect,Installation:instrument wall hung installation;
Sensor gongs grain installation M68×2.0mm, or gongs circle clampon
installation
- Protection level: IP66
- Operation environment: constant pressure, not anti-explosion,
not anti-corrosion
Data sheet
Model | WH |
Applicable weirs | Right triangle weir slot (Open size: 500mm) |
| Parshall flume (Larynx way width: 51mm, 76mm, 152mm, 228mm, 300mm) |
| Rectangular weir (Opening size: 250mm, 500mm, 750mm ) |
Flow range | depending on weirs dimensions to be used, up to 335000 m3/hr |
Flow precision | 5% FS |
Level range | 1m |
Level precision | 0.5% FS |
Sensor blind area | <300mm @ 25C |
Output | 4-20 mA, tri wires |
Display | LCD display, include: four levels four transient flow Eight of the accumulative total flow 16 calendar clock |
Work temperature | 50C , customized available |
Power supply | AC220V |
Outlet way | Sensor leads 20m, instrument standard plugs |
Installation | instrument wall mount, sensor grain installation M49x1.5, or clamp
on |
Protection | IP66 (sensor) |
Dimensions

Features
- Built-in variety of algorithms, suitable for a variety of
standard weirs.
- Stable sensors - Suitable for harsh industrial situations
- Isolated 4~20mA current output. Optional spot bus interface.
- The blind zone can be manually set, shielding the probe near
the interference signal.
- Calibrated at Factory. And if required we shall do
calibration at site.
Sensors

Ultrasonic sensor Static pressure sensor
Applications
Measurement of water flow in Effluent, Waste Water, Rivers, Canals,
Drains, Sewage, etc.
Flow Totalizer parameters
Flow measuring range: Depends on the size of the flume.
Maximum Count: 9999999999
Types of suitable weirs: Triangular weir, rectangular weir,
Parshall flume, etc.
Display accuracy: 1 count. Overall accuracy depends on the input
signal. Different Weirs /
flumes has different accuracies. A triangular weir has 1 to 2% flow
error, a rectangular weir
has 1 to 4% accuracy, a Parshall flume has 3% flow error, etc.
Display: 2.8-inch LCD. Displays Height, Flowrate, Total Flow, etc.
Output
Voltage output: DC 12V or 24V
Signal output: RS485/RS232; 4~20mA; 2 channel relay
Triangle weirs

Installation sample

Advantage
The production capacity is 20000 ultrasonic converter and 100,000
ultrasonic sensor.