Home Companies Shenzhen Wisdomlong Technology CO.,LTD

Output Redundant Power Supply Module SCHNEIDER Automation 140-DAO-842-10

Shenzhen Wisdomlong Technology CO.,LTD

Contact Us

[China] country

Trade Verify

Address: 23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China

Contact name:Eva

Inquir Now

Shenzhen Wisdomlong Technology CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Output Redundant Power Supply Module SCHNEIDER Automation 140-DAO-842-10

Country/Region china
City & Province shenzhen guangdong
Categories Solar Chargers
InquireNow

Product Details

Redundant Power Supply Module SCHNEIDER AUTOMATION 140-DAO-842-10 OUTPUT MODULE 140DAO84210
 
 

 

Specifications

Manufacturer:Modicon Quantum
Series:Quantum I/O
Weight:Ask
Product or component type:AC discrete output modules
Discrete output number:16
Group of channels:4 groups of 4 channels
Supply frequency:47...63 Hz
Voltage drop:1.5 V
Discrete output voltage:83...253 V AC
Addressing requirement:1 output word
Absolute maximum output:400 Vrms 1 cycle AC
 300 Vrms for 10 s AC
Minimum load:5 A
Minimum load current:4 A rms per group
 4 A rms 85...132 V per output
 3 A rms 170...253 V per output
 2.5 mA rms 230 Vrms off state leakage per output
 2 mA rms 115 Vrms off state leakage per output
 16 A rms per module
 1 mA rms off state leakage per output
Surge current:<= 45 A during 1 cycle per group
 <= 30 A during 2 cycles per group
 <= 30 A during 1 cycle per point
 <= 25 A during 3 cycles per group
 <= 20 A during 2 cycles per point
 <= 10 A during 3 cycles per point
DV/Dt:400 V/ms
Response time:<= 0.5 ms at state 1 to state 0
 <= 0.5 ms at state 0 to state 1
Fault indication:Blown fuse
 Loss of field power
Protection type:Internal by RC filter
 Internal output protection by 5 A fuse
Power dissipation:1.85 + (1.1 V x total module load current)
Marking:CE
Local signalling:16 LEDs green input status
 1 LED red external fault detected (F)
 1 LED green bus communication is present (Active)
Bus current requirement:350 mA
Module format:Standard

 

 

 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG-Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X-Emerson VE-,KJ-
Honeywell TC-,TK-GE Modules IC -
Fanuc motor A0-Yokogawa transmitter EJA-
 
 
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
 
 
 
 

Similar Products

140ACI03000

140ACI04000

140ACO02000

140ACO13000

140ARI03010

140AMM09000

140AVI03000

140AVO02000

140ATI03000

140DDI35300

140DDI84100

140DDI85300

140DAI74000

140DAI75300

140DAO85300

140DAO84000

140DAO84210

140DDO35300

140DDO84300

 

 

 

 

 

 

 

 

Estimated Shipping Size
Dimensions: 2" x 4" x 10" (5 cm x 10 cm x 25 cm)
Weight: 1 lbs 2 oz (0.51 kg)

 

 

 

Schneider 140-DAO-842-10 Output Module 140DAO84210 Sealed

PN: 140-DAO-842-10
140DAO84210

Schneider Automation Inc
PN: 140 DAO 842 10
140DAO84210
Output Module

AC Out 100-230V 4X4
TSX Quantum
112698
UPC Number: 3 595861 126985

PV: 00
RL: 77
DOM: 03-2002


Sealed In Factory Packaging

 

 

 

SIL
NOTE: For complete definitions and parameters related to SIL ratings refer to IEC 61508, "Functional safety of electrical/electronic/programmable electronic safety related systems". Provided here is a partial definition.


safety integrity level
discrete level (1 out of a possible 4) for specifying the safety integrity requirements of the safety functions to be allocated to the E/E/PE safety-related systems, where safety integrity level 4 has the highest level of safety integrity and safety integrity level 1 has the lowest

 


(Definition IEC 61508)
SIL2 project (application)
A project (application) that uses a Quantum Safety PLC (140 CPU 651 60S V1.00 or 140 CPU 671 60S V1.00) to implement Safety Functions in a Safety-Related System.


SIL3 project (application)
A project (application) that uses a Quantum Safety PLC (140 CPU 651 60S V2.00 or 140 CPU 671 60S V2.00) to implement Safety Functions in a Safety-Related System.

 


SIR
Safety Integrity requirement
Safety Integrity requirements are derived from a risk assessment and describe the likelihood of a Safety Function to be performed satisfactorily, for instance the degree of certainty necessary for the Safety Function to be carried out.


sniffingreading the configuration out of a PLC

 


SRS
safety requirements specification
specification containing all the requirements of the safety functions that have to be performed by the safety-related systems
(Definition IEC 61508)

 

 

Hot Products

Redundant Power Supply Module SCHNEIDER AUTOMATION 140-DAO-842-10 OUTPUT MODULE 140DAO84210 ...
PLC Programmable Logic Controller Schneider TSX Quantum 140NOM21200 Quantum PLC module Specification...
PLC Programmable Logic Controller SCHNEIDER 140NOC78100 COMMUNICATING MOUDLE SIL NOTE: For complete ...
PLC Programmable Logic Controller SCHNEIDER 140NOC78100 COMMUNICATING MOUDLE This system word counts ...
PLC Programmable Logic Controller Emerson TOPWORX TVH-E20GNEM 316 Stainless Steel Standard 90° Green ...
Industrial Servo Motor Yaskawa Servo Motor SGMGV-09ADA61 200V 0.85KW Motor Only Specifications ...