3RT1064-6AP36 225a Ac 110kw Electrical Contactor Switch

Country/Region china
City & Province zhejiang
Categories Car Chargers
InquireNow

Product Details

3RT1064-6AP36 225A AC ELECTRICAL CONTACTOR 110kW MOTOR CONTACTOR 220V DC CONTACTOR

 

Power contactor, AC-3 225 A, 110 kW / 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S10 Busbar connections Drive: conventional screw terminal

 
Ratings of three-phase motors

The quoted rating (in kW) refers to the output power on the motor shaft (according to the nameplate).

The power rating specifications of the contactors in kW (in accordance with IEC 60947-4-1, Table G) are guide values for 4-pole standard motors at 50 Hz AC and specified voltage (e.g. 400 V AC). The actual starting and rated data of the motor to be switched must be considered when selecting the units. The motor current, motor protection device and the permissible contactor current according to the utilization category must be aligned with each other.

 

Operating mechanism types

3RT1 contactors

The following control and/or operating mechanism versions are available in sizes S6 to S12:

  • Standard operating mechanism with economy circuit for AC and DC operation (switchover from closing coil to holding coil)
  • Solid-state operating mechanism
    Overvoltage damping of the operating mechanism coil is already integrated in the electronics for contactors with solid state operating mechanisms. The operating mechanisms are powered via a supply voltage with an operating range from 0.8 to 1.1 x Us, optionally also controlled depending on the chosen mode of operation. Alternatively, control is also possible via the separate 24 V DC control signal input. Various rated voltage ranges for AC/DC control are available.

    The following versions are available:
    • With two operating modes: Direct control or via CPU input
    • As above, but with additional remaining lifetime indicator (RLT)
    • With fail-safe PLC input for simplification of safety applications (without mode of operation selection)

 

3RT1 contactors

The operating mechanisms for 3RT10..‑.A/-.N/-.P contactors are removable and can be replaced simply by unlocking and pulling them out.

NOTICE: Removal or changing of the operating mechanism is not permitted for 3RT10..‑.S contactors with fail-safe control.

Contactors in safety-related applications

Contactors are a significant part of safety-related applications. They are generally the actuators that perform the switching operation leading to the safe disconnection of the corresponding application or system.

Contactors with mirror contacts according to IEC 60947-4-1 are generally required for use in safety-related applications. Most of our contactors meet this requirement; a corresponding note can be found in the technical product data sheet.

Contactors with increased tamper protection

Increased tamper protection can be ensured either by using our contactor versions with factory-fitted, permanently mounted auxiliary switches which are protected against mechanical external operation (e.g. 3RT2...‑.....-3MA0 contactors and 3RT1...‑....-3PA0 contactors), or by using the 3RT2916-4MA10 or 3RT1926-4MA10 sealable cover as an accessory.

Connection of contactors to fail-safe control modules

While contactors with small powers can be connected directly to the outputs of a fail-safe controller, implementing safety-related applications with standard contactors with higher power is much more complicated and elaborate because of the necessary coupling links. Due to their fail-safe control input, the special versions in sizes S6 to S12 (3RT10..-.S) provide a much simpler way of doing this.

Technical data

Product brand name SIRIUS
Product designation Power contactor
Product type designation 3RT1
General technical data
Size of contactor S10
Product extension  
● function module for communication No
● Auxiliary switch Yes
Power loss [W] for rated value of the current  
● at AC in hot operating state 51 W
● at AC in hot operating state per pole 17 W
Power loss [W] for rated value of the current without load current share typical 7.4 W
Surge voltage resistance  
● of main circuit rated value 8 kV
● of auxiliary circuit rated value 6 kV
maximum permissible voltage for safe isolation  
● between coil and main contacts acc. to EN 60947-1 690 V
Protection class IP  
● on the front IP00; IP20 on the front with cover / box terminal
● of the terminal IP00
Shock resistance at rectangular impulse  
● at AC 8,5g / 5 ms, 4,2g / 10 ms
● at DC 8,5g / 5 ms, 4,2g / 10 ms
Shock resistance with sine pulse  
● at AC 13,4g / 5 ms, 6,5g / 10 ms
● at DC 13,4g / 5 ms, 6,5g / 10 ms
Mechanical service life (switching cycles)  
● of contactor typical 10 000 000
● of the contactor with added electronics-compatible auxiliary switch block typical 5 000 000
● of the contactor with added auxiliary switch block typical 10 000 000
Control circuit/ Control
Type of voltage of the control supply voltage AC/DC
Control supply voltage at AC  
● at 50 Hz rated value 220 ... 240 V
● at 60 Hz rated value 220 ... 240 V
Control supply voltage at DC  
● rated value 220 ... 240 V
Operating range factor control supply voltage rated value of magnet coil at DC  
● initial value 0.8
● Full-scale value 1.1
Operating range factor control supply voltage rated value of magnet coil at AC  
● at 50 Hz 0.8 ... 1.1
● at 60 Hz 0.8 ... 1.1
Design of the surge suppressor with varistor
Apparent pick-up power of magnet coil at AC  
● at 50 Hz 590 V·A
Inductive power factor with closing power of the coil  
● at 50 Hz 0.9
Apparent holding power of magnet coil at AC  
● at 50 Hz 6.7 V·A
Inductive power factor with the holding power of the coil  
● at 50 Hz 0.9
Closing power of magnet coil at DC 650 W
Holding power of magnet coil at DC 7.4 W
Closing delay  
● at AC 30 ... 95 ms
● at DC 30 ... 95 ms
Opening delay  
● at AC 40 ... 80 ms
● at DC 40 ... 80 ms
Arcing time 10 ... 15 ms
Control version of the switch operating mechanism Standard A1 - A2


Main models:

 

3RT1064-6AF36  3RT1064-6AP36  3RT1064-6AV36   

 

 

 

 

Hot Products

3RT1055-6AF36 150A 3 POLE POWER CONTACTOR 75kW DC 110V MOTOR CONTACTOR Power contactor, AC-3 150 A, ...
3RT1056-6AP36 3POLE 400VAC CONTROL CONTACTOR 90kW DC OPERATION 220-240V CONTACTOR Power contactor, ...
3RT1064-6AP36 225A AC ELECTRICAL CONTACTOR 110kW MOTOR CONTACTOR 220V DC CONTACTOR Power contactor, ...
Siemens SIRIUS 3RT1065-6AP36 up to 250 kW DC CONTACTOR 265A 132 kW Power CONTACTOR Power contactor, ...
Factory OEM LC1 Magnetic Three Phases AC Contactor High Quality 3 Poles LC1-D Electrical Contactor ...
China factory new type LC1 AC Contactor 380v coil motor contactor types of Electrical Contactor ...