Home Companies Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

China Food Beverage Electromagnetic Flow Meter / Sanitary Magnetic Flowmeter

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
Active Member

Contact Us

[China] country

Address: No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China

Contact name:Nancy Zhao

Inquir Now

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

China Food Beverage Electromagnetic Flow Meter / Sanitary Magnetic Flowmeter

Country/Region china
City & Province shanghai shanghai
Categories Camera Chargers
InquireNow

Product Details

                                            China Food Beverage Electromagnetic Flow Meter / Sanitary Magnetic Flowmeter

 

1. Introduction

MLF electromagnetic Flowmeter works according to Faraday's law of electromagnetic induction and is composed of sensors and converters. Used to measure the electrical conductivity of liquids or solids. In general, its electrical conductivity should be greater than 5 μ S / cm (the electrical conductivity of tap water and raw water is about 100 ~ 500 μS / cm), can also be used to measure various media such as acid, alkali, salt water, pulp or pulp. But these media cannot contain large amounts of magnetic materials and bubbles.

MLF electromagnetic Flowmeter is an instrument for measuring liquid fluidity. It is widely used in flow measurement in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, waterworks and other industries.

 

 

2. Features

MLF electromagnetic Flowmeter is explosion-proof design.

function of low conductivity measurement.

There are 9 languages(Chinese, English, Korean, Polish, Turkish, French and Portuguese languages) options to meet the needs of different customers.

Have self-regulation function and self-examination.

different outputs are optional: hart, RS485 Profibus ,4-20 mA, frequency, pulse.

 

 

3. Specification

MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
Accuracy±0.2% or ±0.5%
Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
FlangeGB, ANSI, JIS, BS, Others
PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection ClassIP65, IP66, IP67, IP68
Medium Temperature-25~180
(Please refer to liner material)
-25~80(Please refer to liner material)-25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability≤±0.1% or ±0.25%
Analog Output Error≤±0.02mA
Velocity0.3~10m/s
Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output4-20mA, Pulse, RS485, Hart, Profibus

 

 

4. Selection of Electrode Materials

Electrode MaterialMain Performance
316LGood corrosion resistance of nitric acid, sulfuric acid, acetic acid, alkaline liquid at room temperature < 5%, sulfite, seawater, acetic acid and other corrosion under certain pressure, can be widely used in petrochemical urea, vinylon and so on.
HbGood resistance to all concentrations below the boiling point of hydrochloric acid, but also resistant to non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid, organic acid corrosion.
HcResistant to the corrosion of oxidizing acid, such as nitric acid and mixed acid. The mixture of chromic acid and sulfuric acid, oxidized salts, such as Fe3+, Q3+, and other oxidants, such as the mixture of hypochlorite solution and seawater at higher than normal temperature.
TiResistant to corrosion of seawater, various chlorides, hyalphates, oxidizing acids (including smoke nitric acid), organic acids or alkalis, but not pure reduced acids (e.g. sulphuric acid, hydrochloric acid). However, if the acid contains oxidants (e.g. nitric acid, Fe3, Q3), corrosion resistance is reduced.
TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

 

 

5. Dimensional Sketches

a. Dimension of Converter

                                                                      Divided Type

 

 

                                                                      Integrated Type

 

                                                                  Battery Powered Type

 

 

b. Dimension of Sensor

 

 

Pipeline DiameterDimension
LWH
1516095130
20160105137
25160115150
32160135160
40200145175
50200160185
65200180205
80200195215
100250215235
125250245275
150300280300
200350335355
250400400405
300500455460
350500515520
400600575580
450600635630
500600710685
600600835795
700700905910
80080010201030
90090011201120
1000100012451250
1200120014651470

 

6. Configuration

MLF Series Electromagnetic Flow Meter Configuration
ModelMLF
Sensor InstallationSFlange Type Sensor
CInsertion Type Sensor
OOthers
Pipeline Diameter1010mm
1515mm
2020mm
...... 
20002000mm
Electrode InstallationFStandard Fixed Type
Electrode MaterialA316L SS
BHb
CTa
DTi
EHc
FTungsten Carbide
GOthers
Liner MaterialRRubber
PPTFE
OOthers
Pipe MaterialB304 SS (Standard)
C316 SS
Flange TypeGGB (Standard)
AANSI
JJIS
BBS
OOthers 
Flange MaterialA304 SS
B316 SS
C#20 Carbon Steel (Standard)
Cover MaterialD304 SS
E316 SS
FCarbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange0Without Matching Flange (Standard)
1With Matching Flange
Ground Ring0Without Ground Ring (Standard)
1With Ground Ring
Rated Pressure101.0MPa
161.6MPa
252.5MPa 
404.0MPa
Working TemperatureE≤60℃
H≤180℃(Divided Type)
TypeIIntegrated Type
DDivided Type
OutputPPulse
A4-20mA
GRS485
HHart
QOthers
Power Supply0220VAC
124VDC
2Battery-powered
Protection Class0IP65 (Integrated/Divided Type)
1IP67 (Divided Type)
2IP68 (Divided Type)
Other FeaturesRHeat Energy Function
PWith PT1000
BWithout PT1000
Explosion Proof0None
EXExplosive Proof

 

 

7. Instrument Detection & Maintenance

 

The electromagnetic Flowmeter has the function of self-diagnosis. In addition to power supply and hardware circuit failures, the system also gives an alarm to other faults in general use. These messages are prompted in the lower right corner of the screen.

 

1 Maintenance and repair.

A) the sensor installation site should meet the requirements of Section 4, please keep the shell clean and tidy.

B) the transmitter should be placed in a clean, ventilated and dry place.

C) it needs to be checked every two years, and for high-precision users, the instrument needs to be submitted for review.

 

2 Transportation and storage.

A) the equipment must be packed before transportation and handled carefully during loading and unloading.

B) the storage place must be dry and ventilated to avoid the erosion of corrosive gases and the ambient temperature should not be too low or too high.

C) the storage time should not exceed three years.

 

3. Out-of-the-box inspection.

A) the package cannot be opened with a heavy hammer, be careful not to damage the instrument.

B) carefully check the contents according to the packing list.

 

8. Advantages & Disadvantages

There are numerous benefits to using electromagnetic flowmeters to perform fluid flow measurements. They are generally non-invasive and have no moving parts, reducing the risk of breakdowns and the frequency of repairs. A decrease in flowmeter pressure is also usually no greater than that of an equivalent pipe length, reducing the piping costs. Some of the other major advantages provided by magnetic flowmeters include:

  • Power usage is relatively low, with electrical power requirements as low as 15 watts for some models.
  • They are mechanically obstructionless and can be equipped with abrasion-resistant liners, making them effective for measuring slurries and other erosive fluids.
  • They are capable of dealing with most kinds of acids and bases, as well as water and water-based solutions, due to lining materials that are both insulators and have corrosion resistance.
  • Relatively small amounts of electrode metals are needed for magnetic flowmeters.
  • They can measure both very low flows and very high volume flow rates, with a minimum diameter of roughly 0.125 inches and a maximum volume of up to 10 cubic feet.
  • They can usually measure multidirectional flow, either upstream or downstream.

Despite these advantages, magnetic flowmeters also present certain difficulties for flow rate measurement. These flowmeters are only effective on conductive fluids, and materials such as unmixed hydrocarbons and gases cannot be measured. However, magnetic materials themselves may also present problems, as hydrodynamic effects can alter the normal flow pattern and disturb the velocity rate enough to interfere with operations. Depending on their size and capacity, magnetic flowmeters can be relatively heavy, and those with higher corrosion and abrasion resistance can be expensive.

Hot Products

Magnetic Flow Meter For Sewage Water/Wastewater DN15-DN200 Application 1. Introduction The MLF ...
Magnetic Flow Meter For Pulp And Paper Industry Slurry Application 1. Introduction MLF electromagnet...
Mag Flow Meter With Carbon Steel DN800 Rubber Liner PN10 Flanges 1. Introduction MLF electromagnetic ...
China High Quality Mag Flow Meter Electromagnetic Water Flow Meter​ 1. Introduction The MLF ...
China Food Beverage Electromagnetic Flow Meter / Sanitary Magnetic Flowmeter 1. Introduction MLF ...
China Factory Mag Flow Meter 100mm (4 Inch) ANSI Flange Connection 1. Introduction MLF electromagnet...