                    Digital Electromagnetic Flow Meter Low Price DN15 Flange Type

 

1. What are Electromagnetic Flow Meters?
Electromagnetic flow meters, also called mag meters or magnetic meters, are volumetric flow meters which do not have any moving parts to wear, reducing the need for maintenance or replacement. Accuracy over a wide flow range can be as good as ± 0.5% of flow rate or better.

They feature an obstruction-free design which eliminates flow impediment, and operate with electrodes embedded on opposite sides of the flow tube or sensor to pick up the signal. Mag meters perform extremely well in many municipal and processing applications, and have become the meter of choice for measuring conductive liquids such as water or slurry.

 

2. Working Principle

 

The principle of the sensor is based on Faraday's law of electromagnetic induction. It is installed a pair of detection electrodes on the pipe wall,where the measurement pipe axis and magnetic field lines are vertical. When the conductive liquid cuts magnetic field lines and produces induced electromagnetic force.Which can be measured by the two electrodes on the meter pipe.The result can be calculated by formula: Induced electromotive force,(flow signal)

E=KBDV
E--Induced electromotive force,V;
K--meter constant;
B--Magnetic flux density,T;
D--Internal diameter of measuring pipe,m;
V--Average velocity of pipe section,m/s.
1MLF Series Electromagnetic Flow Meter
Assume the volume of liquid as qv(m3/s),qv=πD2V/4),so in the formula E=(4kB/πD)qv=kqv, K is meter constant,K=4kB/πD.
Actually, the electromagnetic flow meter consists of two parts, transmitter and sensor, the measuring electrodes inspect the electromotive force, and transmit to the converter, the converter provides excitation current. E is usually called a flow signal, after processing the flow signal by converter, output 4~20 mA/pulse(or frequency) signal which is proportional to the flow rate, then the flow rate recording,adjusting can be achieved.

 

 

3.How Does A Magnetic Flow Meter Work?

Magnetic flow meters use a magnetic field to generate and channel liquid flow through a pipe. A voltage signal is created when a conductive liquid flows through the flowmeter’s magnetic field. The faster the flow of the fluid, the greater the voltage signal generated. Electrode sensors located on the flow tube walls pick up the voltage signal and send it to the electronic transmitter, which processes the signal to determine liquid flow.

 

 

4. Advantages of using Electromagnetic Flow Meters
The main advantages of using magmeters is that they require less maintenance, and can be ordered for very large line sizes. Some can be installed with a simple hot tap which does not require shutting down the line. Mag meters also have the benefit of adding a level of trust for consumers: they hold the service provider accountable for the actual water being produced and/or billed. These efforts will assist with preservation of our water resources while improving profitability for the utility.

5. Disadvantages of using Magnetic Flow Meters
It depends on the meter itself. Some flow tube meters have a liner which can separate from the meter causing system damage and requiring maintenance. Mag meters don't work on non-conductive fluids such as oils, steam or gas.

 

6. Specification

MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
Accuracy±0.2% or ±0.5%
Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
FlangeGB, ANSI, JIS, BS, Others
PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection ClassIP65, IP66, IP67, IP68
Medium Temperature-25~180
(Please refer to liner material)
-25~80(Please refer to liner material)-25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability≤±0.1% or ±0.25%
Analog Output Error≤±0.02mA
Velocity0.3~10m/s
Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output4-20mA, Pulse, RS485, Hart, Profibus

 

 

7. Configuration

MLF Series Electromagnetic Flow Meter Configuration
ModelMLF
Sensor InstallationSFlange Type Sensor
CInsertion Type Sensor
OOthers
Pipeline Diameter1010mm
1515mm
2020mm
...... 
20002000mm
Electrode InstallationFStandard Fixed Type
Electrode MaterialA316L SS
BHb
CTa
DTi
EHc
FTungsten Carbide
GOthers
Liner MaterialRRubber
PPTFE
OOthers
Pipe MaterialB304 SS (Standard)
C316 SS
Flange TypeGGB (Standard)
AANSI
JJIS
BBS
OOthers 
Flange MaterialA304 SS
B316 SS
C#20 Carbon Steel (Standard)
Cover MaterialD304 SS
E316 SS
FCarbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange0Without Matching Flange (Standard)
1With Matching Flange
Ground Ring0Without Ground Ring (Standard)
1With Ground Ring
Rated Pressure101.0MPa
161.6MPa
252.5MPa 
404.0MPa
Working TemperatureE≤60℃
H≤180℃(Divided Type)
TypeIIntegrated Type
DDivided Type
OutputPPulse
A4-20mA
GRS485
HHart
QOthers
Power Supply0220VAC
124VDC
2Battery-powered
Protection Class0IP65 (Integrated/Divided Type)
1IP67 (Divided Type)
2IP68 (Divided Type)
Other FeaturesRHeat Energy Function
PWith PT1000
BWithout PT1000
Explosion Proof0None
EXExplosive Proof

 

8. Maintance

The electromagnetic flowmeter has a self-diagnostic function. In addition to power supply and hardware circuit failures, the system also alarms other failures in general use. These messages will give corresponding prompts in the lower right corner of the screen.


1 Maintenance and repair
a) The sensor installation site should meet the requirements of Section 4, please keep the housing tidy;
b) The transmitter should be placed in a clean, ventilated and dry place;
c) It needs to be inspected every two years. For high-precision users, the instrument needs to be submitted for review.

2 Transportation and storage
a) The instrument must be packaged before transportation, and be handled with care when loading and unloading.
b) The storage place must be dry and ventilated to avoid corrosive gases, and the ambient temperature should not be too low or too high;
c) The storage time should not exceed three years.

 

9.Company Profile

 

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.


Our products are widely used in various fields, including electricity, chemical industry, metallurgy, brewing, oil and gas, textile, water conservancy, environmential protection, etc.

We own independent-courtyard modemized manufacturing workshops and an open office building. Melan has accumlated production and management experience in instruments from European and American and domestic famous companies.

We own first-class talent team, and all the products have reached advanced level at home and abroad. We provide our customers with complete and professional test control solutions and high-tech and high-quality products.

Melan is your reliable friend and partner. We are willing to try our best as dedication and perfection as motivation.

 

10.FAQ

Q: How long will you give me the reply?
A: We will contact you in 5 hours as soon as we can.

Q: What is the warranty of your prducts?
A: Our warranty is 12 months after the shipping date.

Q: What is the lead time of your products?
A: Normally our factory lead time is 10-12 working days.

Q: Can I OEM your products?
A: OEM and ODM customization are welcomed.

Q: What is your MOQ?
A: We have no MOQ limit, small quantity order is acceptable.

Q:What is the transport?
A: Express such as DHL, FedEx, UPS for freight prepaid, and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by sea.

Hot Products

Low Cost Magnetic Flowmeter Water Mould Flow Meter DN100 With Modbus RS485 1. What are Electromagnet...
Soft Water Magnetic Flowmeters Food And Beverage Variable Area Flow Meter PTFE Lining 1. What are ...
Magnetic Flow Meters With TriClover And ANSI Flanges Remote Converter Transmitters 1. What are ...
Battery Operated Magnetic Flowmeters Acid Resistant Flow Meters 1. What are Electromagnetic Flow ...
Digital Electromagnetic Flow Meter Low Price DN15 Flange Type 1. What are Electromagnetic Flow ...
Magnetic Flow Meter Digital Slurry Flow Meterr 316L Customized With Carbon Steel 1. What are ...