Type | Specification Code | Illustration |
ML2¨¨¨W | --------------------------------- | Diffused Silicon Pressure Transmitter |
Transducer | 0-------------------------------- | Diffused Silicon Transducer |
Accuracy | 8-------------------------------- | ±0.2% |
5-------------------------------- | ±0.1% |
Output | 8-------------------------------- | 4-20mA |
1-------------------------------- | 4-20mA, HART |
| W-------------------------------- | |
Contact Medium Mode | F-------------------------------- | Remote Transmission Flange Installation Type |
G-------------------------------- | High Temperature Heat Radiation Type(0-200℃) |
P-------------------------------- | Flat Diaghragm Contact Type |
L-------------------------------- | Thread Connection * |
Connection Mode | 2-------------------------------- | Flange Connection (Note 1) |
3-------------------------------- | M20x1.5 * |
4-------------------------------- | Other Thread Connection (Note 2) |
Measuring Range | 1-------------------------------- | 0-5~35KPa |
2-------------------------------- | 0-35~100KPa |
3-------------------------------- | 0-50~200KPa |
4-------------------------------- | 0-100~350KPa |
5-------------------------------- | 0-200~700KPa |
6-------------------------------- | 0-0.5~2.1MPa |
7-------------------------------- | 0-1~3.5MPa |
8-------------------------------- | 0-3~7MPa |
9-------------------------------- | 0-7~21MPa |
0-------------------------------- | 0-15~40MPa |
Y-------------------------------- | Specific Range (Note 3) |
Display Header | D-------------------------------- | Multiple Parameters & Modes Digital LED Display Header (Note 4) |
L-------------------------------- | Common LED Header |
Z-------------------------------- | Pointer Header |
N-------------------------------- | No Header |
Electrical Connection | 5-------------------------------- | M20x1.5 Waterproof Concentrator |
Power Supply | -A------------------------------- | 24VDC |
-B------------------------------- | 12VDC |
Additional Type | -NF1---------------------------- | Ex-proof Certificate: Exd II CT6 |
-NS1---------------------------- | Intrinsic Safety Type: Exi II CT4 |
-M------------------------------- | Other Requirements(Note5) |
Remarks: | | |
e.g.:ML2088WLM6L5-A-NF1 0-1.6MPa |
e.g.:ML2051WLM7D5-B-NS1 0-2.5MPa |
Note1: Please indicate the flange size behind type if you choose
this code |
Note2: Please indicate the thread size behind type if you choose
this code |
Note3: Please indicate specific range behind type |
Note4: Only output code1 is available |
Note5: Please note in order |
*: Standard | | |