Home Companies Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Conductive Liquid 2000mm Electromagnetic Current Meter

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
Active Member

Contact Us

[China] country

Address: No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China

Contact name:Nancy Zhao

Inquir Now

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Conductive Liquid 2000mm Electromagnetic Current Meter

Country/Region china
City & Province shanghai shanghai
Categories Other Electric Power Tools
InquireNow

Product Details

                                     Magmeter Designed for Use with Conductive Liquid in15mm to 2000mm

 

1. Introduction

MLF electromagnetic flowmeter is based on Faraday's law of electromagnetic induction and consists of sensors and converters. Used to measure the conductivity of a liquid or solid. Generally, its conductivity should be greater than 5μS/cm (the conductivity of tap water, raw water is about 100~500μS/cm). it can also be used to measure various media such as acid, alkali, brine, pulp or pulp and other medium. But these medium can not contain a large number of magnetic substances and bubbles.

MLF electromagnetic flowmeter is an instrument to measure liquid fluidity. Widely used in metallurgy, chemical, paper, environmental protection, petroleum, textile, food, urban management, water plants and other industries of flow measurement.

 

2. Quick Details

1) It is high resistance, fast response design can make undistorted collection of weak signal and fast response to the flow changes. Its range rate can reach 100:1.

2) MLF electromagnetic flowmeter is explosion-proof design.

3) Function of low conductivity measurement.

4) There are nine language(Chinese, English, Korean, Polish, Turkish, French and Portuguese languages) options to meet the needs of different customers.

5) It has the function of self-regulation and self-examination.

6) Different outputs are optional: Hart,RS485 Profibus,4-20mA, frequency, pulse.

 

 

3. Selection of Liner Material

Liner MaterialMain PerformanceApplication
PTFE

1 It has the most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong alkali and various organic solvents, but not resistant to chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, and liquid oxygen And ozone corrosion.

2 Low wear resistance.

3 Low negative pressure resistance.

1. -25~140℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare medium

CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

1. <80℃

2. Be able to measure sewage and mud

PU

1. Very good abrasive resistance, flexibility.

2. Low acid and alkali resistance.

1. <65℃

2. Neutral strong abrasion resistance medium

Hard Rubber

1 Resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide and potassium hydroxide

2 Avoid strong oxidants

1. <80℃

2. General acid, alkali, salt solution

PFA

1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

2. High material strength, resistance to aging, better than PTFE, EFP in high temperature 

3. Injection molding for higher negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

FEP(F46)

1. Hydrophobicity and non-viscous

2. Corrosion resistance is inferior to PFA

3. Negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

 

4. Selection of Electrode Materials

Electrode MaterialMain Performance
316LGood corrosion resistance to nitric acid, less than 5% corrosion of sulfuric acid, acetic acid, alkaline liquid, sulfite, seawater and acetic acid under certain pressure at room temperature, and can be widely used in petrochemical urea, vinylon and so on
Hb

Good resistance to hydrochloric acid with concentration lower than boiling point and corrosion of non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid.

HcResistant to the corrosion of oxidizing acid, such as nitric acid and mixed acid. The mixture of chromic acid and sulfuric acid, oxidized salts, such as Fe3+, Q3+, and other oxidants, such as the mixture of hypochlorite solution and seawater at higher than normal temperature.
TiResistant to the corrosion of seawater, various chlorides, hypochlorite, oxidized acid (including fuming nitric acid), organic acid or alkali, but not pure reducing acid (such as sulfuric acid and hydrochloric acid). However, if the acid contains oxidants (such as nitric acid, Fe3+, Q3+), the corrosion resistance will decrease.
TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-IrHave good corrosion resistance of all acid, and  can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

 

 

5. Dimensional Sketches

a. Dimension of Converter

                                                                      Divided Type

 

 

                                                                      Integrated Type

 

                                                                  Battery Powered Type

 

 

b. Dimension of Sensor

 

 

Pipeline DiameterDimension
LWH
1516095130
20160105137
25160115150
32160135160
40200145175
50200160185
65200180205
80200195215
100250215235
125250245275
150300280300
200350335355
250400400405
300500455460
350500515520
400600575580
450600635630
500600710685
600600835795
700700905910
80080010201030
90090011201120
1000100012451250
1200120014651470

 

6. Configuration

MLF Series Electromagnetic Flow Meter Configuration
ModelMLF
Sensor InstallationSFlange Type Sensor
CInsertion Type Sensor
OOthers
Pipeline Diameter1010mm
1515mm
2020mm
...... 
20002000mm
Electrode InstallationFStandard Fixed Type
Electrode MaterialA316L SS
BHb
CTa
DTi
EHc
FTungsten Carbide
GOthers
Liner MaterialRRubber
PPTFE
OOthers
Pipe MaterialB304 SS (Standard)
C316 SS
Flange TypeGGB (Standard)
AANSI
JJIS
BBS
OOthers 
Flange MaterialA304 SS
B316 SS
C#20 Carbon Steel (Standard)
Cover MaterialD304 SS
E316 SS
FCarbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange0Without Matching Flange (Standard)
1With Matching Flange
Ground Ring0Without Ground Ring (Standard)
1With Ground Ring
Rated Pressure101.0MPa
161.6MPa
252.5MPa 
404.0MPa
Working TemperatureE≤60℃
H≤180℃(Divided Type)
TypeIIntegrated Type
DDivided Type
OutputPPulse
A4-20mA
GRS485
HHart
QOthers
Power Supply0220VAC
124VDC
2Battery-powered
Protection Class0IP65 (Integrated/Divided Type)
1IP67 (Divided Type)
2IP68 (Divided Type)
Other FeaturesRHeat Energy Function
PWith PT1000
BWithout PT1000
Explosion Proof0None
EXExplosive Proof

 

Hot Products

Battery Powered Electromagnetic Flow Meter with SS304 Boday for Chemicals​ 1. Introduction MLF ...
Magnetic Battery Operated Flow Meter for Water and Wastewater 1. Introduction The MLF electromagneti...
Food Sanitary Beverage Electromagnetic Flow Meter with High Performance 1. Introduction MLF ...
Flanged Sensor for Mag Flow Meter MLF Model wich Cheap Price Made in China 1. Introduction MLF ...
Magmeter Designed for Use with Conductive Liquid in15mm to 2000mm 1. Introduction MLF electromagneti...
Melan Brand MLF Model Electromagnetic Flow Meter with PTFE Liner 1. Introduction The MLF electromagn...