                                       OEM Electromagnetic Flow Meter Sensor for Conductive Liquid

 

1. Introduction

MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction, and is composed of sensors and converters. Used to measure the conductivity of liquid or solid. In general, its conductivity should be greater than 5μs/cm (tap water and raw water conductivity is about 100 ~ 500μs/cm), and it can also be used to measure acid, alkali, brine, pulp or pulp and other media. However, these media cannot contain a large amount of magnetic substances and bubbles.

MLF electromagnetic flowmeter is an instrument for measuring liquid fluidity. Widely used in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries.

 

2. Features

MLF electromagnetic flowmeter is explosion-proof design.

Low conductivity measurement function.

There are nine languages(Chinese, English, Korean, Polish, Turkish, French and Portuguese languages) options to meet the needs of different customers.

It has self-regulation function and self-test.

Different outputs are optional: Hart, RS485, Profibus, 4-20mA, frequency, pulse.

 

 

3. Specification

MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
Accuracy±0.2% or ±0.5%
Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
FlangeGB, ANSI, JIS, BS, Others
PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection ClassIP65, IP66, IP67, IP68
Medium Temperature-25~180
(Please refer to liner material)
-25~80(Please refer to liner material)-25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability≤±0.1% or ±0.25%
Analog Output Error≤±0.02mA
Velocity0.3~10m/s
Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output4-20mA, Pulse, RS485, Hart, Profibus

 

4. Selection of Electrode Materials

Electrode MaterialMain Performance
316L

Good corrosion resistance of nitric acid, at room temperature <5% sulfuric acid, acetic acid, alkaline liquid, a certain pressure of sulphate, seawater, acetic acid and other corrosion, can be widely used in petrochemical urea, veline and so on.

Hb

Good resistance to all concentrations below the boiling point of hydrochloric acid, but also resistant to non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid, organic acid corrosion.

Hc

Corrosion of oxidizing acids, such as nitric acid, mixed acids. A mixture of chromic acid and sulfuric acid, oxidized salts, such as Fe3,Q3, and some other oxidants, such as a mixture of hypochlorite solution and seawater above normal temperature.

Ti

Resistant to corrosion of seawater, various chlorides, hypochlorite, oxidizing acids (including fuming nitric acid), organic acids or bases, but not pure reductive acids (e.g., sulfuric acid, hydrochloric acid) etc. but if the acid contains oxidants (such as nitric acid, Fe3,Q3), the corrosion resistance will decrease.

TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

 

 

5. Dimensional Sketches

a. Dimension of Converter

                                                                      Divided Type

 

 

                                                                      Integrated Type

 

                                                                  Battery Powered Type

 

 

b. Dimension of Sensor

 

 

Pipeline DiameterDimension
LWH
1516095130
20160105137
25160115150
32160135160
40200145175
50200160185
65200180205
80200195215
100250215235
125250245275
150300280300
200350335355
250400400405
300500455460
350500515520
400600575580
450600635630
500600710685
600600835795
700700905910
80080010201030
90090011201120
1000100012451250
1200120014651470

 

6. Instrument Detection & Maintenance

 

Electromagnetic flowmeter has self-diagnosis function. In addition to power supply and hardware circuit faults, the system also alarms other faults in general use. These messages give corresponding tips in the lower right corner of the screen.

 

1 Maintenance and repair

A) the sensor installation site shall meet the requirements of section 4, and please keep the housing clean and tidy;

B) The transmitter shall be placed in a clean, ventilated and dry place;

C) it needs to be checked every two years. for high-precision users, the instrument needs to be submitted for review.

 

2 Transportation and storage

A) the instrument must be packed before transportation and handled with care.

B) The storage place must be dry and ventilated to avoid corrosive gas erosion, and the ambient temperature should not be too low or too high;

C) the storage time should not exceed three years.

 

3. Unpacking inspection

A) the package cannot be opened with a heavy hammer, so be careful not to damage the instrument.

B) carefully check the contents according to the packing list.

 

 

7. Product Photos

 

 

Hot Products

Magnetic Flow Meter for Industrial Process Measurement with High Performance​ 1. Introduction MLF ...
Electromagnetic Flow Meter Used for DM Water Plant with Low Cost​ 1. Introduction The MLF electromag...
OEM Electromagnetic Flow Meter Sensor for Conductive Liquid 1. Introduction MLF electromagnetic ...
High Accuracy Water Mag Flow Meter / Magnetic Flowmeter DN200 1. Introduction The MLF electromagneti...
Accuracy Digital Electromagnetic Flow Meter for Water Line Fluid Measurement for Sale 1. Introductio...
Electromagnetic Flow Meter for Water Flow Rate Measurement with 1 Inch / 3 Inch And So On 1. ...