Capacitance Level Pressure Transmitter with Flange Mounting Intelligent Type

 

1. Introduction

The mounting of ML3000S flanged liquid level transmitter executes ANSI standard. It has 3” and 4” flanged specifications and has 150LB(2.5MPa) flange class. Regarding to specific installation dimension, please see the bellowed drawing. If users apply GB9116-88 standard, please note: DN=80, PN=2MPa. Material of the contacting liquid diaphragm: 316L, Hastelloy C-276, Monel, Tantalum and so on.

If customer don’t have clear indication, we will supply mounting flange of 3” specification, 150LB and 316L contacting liquid diaphragm.

 

2. Technical Parameters

  • Accuracy: ±0.5%, ±0.075%
  • Dead zone: None(≤0.1%)
  • Stability: Less than the absolute value of basic error of maximum range with 6 months
  • Vibration Effect: With 200Hz vibration frequency and error that of ±0.05%/g upper limit of measuring range in arbitrary axis.
  • Power Supply: <0.005%/V output range
  • Load Effect: No load effect under stable power supply

 

3. Configuration

TypeSpecification CodeIllustration
ML3¨¨¨S---------------------------------Flange Mounting Intelligent Liquid Level & Pressure Transmitter
Accuracy3--------------------------------±0.5%
0--------------------------------±0.075%
Output5--------------------------------4-20mA, HART
Sensor1--------------------------------Capacitive Sensor
 S-------------------------------- 
Connection Medium ModeL--------------------------------Mounting Flange Type
Measuring Range4--------------------------------0-6.2~37.4KPa(0-635~3810mmH2O)
5--------------------------------0-31.1~186.8KPa(0-3175~19050mmH2O)
6--------------------------------0-117~690KPa(0-1.2~7Kgf/cm2)
Flange Dimension & Isolation Diaphragm Nominal DiameterInsertion DepthIsolation Diaphragm
A0--------------------------------80mmFlat316 SS
A2--------------------------------80mm50316 SS
A4--------------------------------80mm100316 SS
A6--------------------------------80mm150316 SS
B0--------------------------------100mmFlat316 SS
B2--------------------------------100mm50316 SS
B4--------------------------------100mm100316 SS
B6--------------------------------100mm150316 SS
C0--------------------------------80mmFlatHastalloy C
C2--------------------------------80mm50Hastalloy C
C4--------------------------------80mm100Hastalloy C
C6--------------------------------80mm150Hastalloy C
D0--------------------------------100mmFlatHastalloy C
D2--------------------------------100mm50Hastalloy C
D4--------------------------------100mm100Hastalloy C
D6--------------------------------100mm150Hastalloy C
E0--------------------------------80mmFlatTantalum
F0--------------------------------100mmFlatTantalum
Flange DimensionA--------------------------------3" 150lB
B--------------------------------4" 150lB
C--------------------------------3" 300lB
D--------------------------------4" 300lB
Q--------------------------------Other requirements
Display HeaderD--------------------------------Multiple Parameters and Methods Digital LED Display Header
N--------------------------------No Display Header
Electrical Interface5--------------------------------M20*1.5 Waterproof Concentrator
Additional Type-NF1----------------------------Ex-proof Security Certification: Exd II CT6
-NS1----------------------------Intrinsic Safety Certification: Exi II CT4
-M-------------------------------Other requirements are available
Remarks:
e.g.:ML3051SL-5A0AD5-NF1

 

4. Dimension

      

 

 

 

 

 

    

 

 

                     

 

             

 

 

 

 

 

 

 

        

 

The flange gasket is chosen by customers according to connecting liquid medium features. Our company recommends Asbestos Rubber,Nitrile Rubber, Fluorine Rubber, Nylon, Teflon and so on.

 

 

 

 

Hot Products

Flange Mounting Intelligent Capacitance Level Transmitter with Wide Measuring Range 1. Introduction ...
Capacitance Level Pressure Transmitter with Flange Mounting Intelligent Type 1. Introduction The ...
Industry Hydrostatic Type Level Transmitter Two - wired Analog 24VDC 1. Introduction ML2000T series ...
0 - 10V Hydrostatic Level Transmitter with 0.2% / 0.1% Accuracy 1. Introduction ML2000T series ...
High Stability Static Pressure Transmitter Flange Type Connection PVC Cable With Shield 1. ...
Cheap Hydrostatic China Level Transmitter with Hart / RS485 Output 1. Introduction ML2000T series ...