Guangzhou Jin Lun Electric Equipment Co.,Ltd |
|
Stainless steel sheet 380 provide bathroom live hot water bringing a comfortable environment
Technology Specification
Feature:
1. Economical operation
Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.
2. Safety
Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated
3. Environmental friendly
Transfer heat that’s already in the environment; Low CO2 emissions.
4. Easy operation
With intelligent control systems which convenient and simple operation
5. Constant hot water supply
Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.
6. Wide application
7. Heat pump water heater can be applied to sanitary hot water, house heating .
Advantage
1.Adopt world famous brand compressor.
2.High purity refrigerant: R410a/R407C, to make sure high COP.
3.Optimized system design: R410a/R407C system with accurate
capillary tube or electronic expansion valve, achieving stable
operation and high COP in wide ambient temperature range.
4.Big heat exchangers: big hydrophilic fin-tube heat exchanger, big
titanium coil heat exchanger, (maybe the biggest one in China), to
make sure high COP in wide ambient temperature range.
5.Big and strong case: allowing built-in big heat exchangers, and
reducing vibration and noise.
6.Advanced control: the quick-mind microchip LCD controller (Carel
controller is optional) provides extremely convenient control on
the heat pump.
7.Comprehensive protection: the heat pump is protected fully,
including water flow, water temperature, compressor pressure and
temperature, temperature for heat exchanger, and anti-freezing for
heat exchanger and so on.
8.Quiet: using the high-efficiency, low noise rotary or scroll
compressor, low noise fan.
A. Payment service
1. T/T
2. L/C (for container order only)
B. Technical service
1. We calculate the capacity and recommend the best models.
2.We supply you the professional refrigeration technical support and electronic technical support for your installation, debugging and operation.
3. We supply the spare parts and technical support in and after the warranty time.
4. We supply the training course to your workers at our factory if you need.
5. We can offer site training to your workers in your place which is negotiable.
C. After-sales service
1. Technical support for your installation, operation and maintenance.
2. Standard warranty time: One years’warranty for heat pumps
You can also pay for extended warranty or we can renegotiate the longer warranty period.
3. Spare parts and technical support at most economic prices after the warranty.
FAQ
Why us?
1.Timely Delivery, considerate sales after service
2.Many Years quality warranty,OEM service.
3.Top Craftmanship, All products 100% tested
4.Preferential freight by Famous shipping company
5.New Design,Very popular style products recommendation for your local market
Packaging & Shipment
1>Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.
2>Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .
3>All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.
4>Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.
5>Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)
Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters
Delivery Time :15 work days after arrival of down payment
ABOUT AS
1). We were established in 2001.
2).We are a professional heat pump manufacturer,Located arround baiyun Air port
3). We are trading on Meeting Brand ,Meeting heat pump Well-know brand we operate in Europe market
4). Our company has been inspected and certificated by TUV and SGS.
5). We are the one of the first manufacturers whose heat pumps are with top COP gaining grants from Chinese government.
6). We pass ISO9001 quality management system and ISO14000 environment protection system
7). Our testing laboratory can test heat pump up to 60KW heating capacity and create testing air temperature condition during -25DegC~45DegC,according to EN14511 standard.
9). Our leading products: Air to water heat pump , DC inverter heat pump, High water temperature heat pumps
Monoblock house heating heat pumps ,Split heat pump ,Super low noise heat pump
Heat pump dryer ,Ground source heat pump , water to water heat pump , swimming pool heat pump
MODEL | Unit | MD10D | |
Rated heating capacity | KW | 3.5 | |
Rated Cooling capacity | 1.8 | ||
Hot water supply | L/h | 75 | |
Average heating input power | KW | 0.75 | |
Rated heating input current | A | 6 | |
Rate outlet water temp | ℃ | 55 | |
COP | 3.65 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 1000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 29 | |
MODEL | Unit | MD15D | |
Rated heating capacity | KW | 5 | |
Rated Cooling capacity | 3 | ||
Hot water supply | L/h | 100 | |
Average heating input power | KW | 1.25 | |
Rated heating input current | A | 6 | |
Rate outlet water temp | ℃ | 55 | |
COP | 3.65 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 1600L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 40 | |
MODEL | Unit | MD20D | |
Rated heating capacity | KW | 7 | |
Rated Cooling capacity | 5 | ||
Hot water supply | L/h | 150 | |
Average heating input power | KW | 1.84 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 60 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A//R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 2000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 55 | |
MODEL | Unit | MD30D | |
Rated heating capacity | KW | 12 | |
Rated Cooling capacity | 7 | ||
Hot water supply | L/h | 260 | |
Average heating input power | KW | 3 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 60 | |
COP | 4 | ||
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 54 | |
Dimension | W*D*H | mm | 1120*490*710mm |
Packing size | W*D*H | mm | 1190*520*865mm |
Unit weight | KG | 108 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 3000L/h | |
Water pressure down | Kpa | 40 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 100 | |
MODEL | Unit | MD40D | |
Rated heating capacity | KW | 16 | |
Rated Cooling capacity | 10 | ||
Hot water supply | L/h | 360 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 4000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 125 | |
MODEL | Unit | MD50D | |
Rated heating capacity | KW | 18 | |
Rated Cooling capacity | 12 | ||
Hot water supply | L/h | 400 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | C | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 5000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 150 | |
MODEL | Unit | MD60D | |
Rated heating capacity | KW | 21 | |
Rated Cooling capacity | 15 | ||
Hot water supply | L/h | 520 | |
Average heating input power | KW | 5.68 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 210 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 6000 | |
Water pressure down | Kpa | 48 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 175 | |
MODEL | Unit | MD100D | |
Rated heating capacity | KW | 36 | |
Rated Cooling capacity | 24 | ||
Hot water supply | L/h | 800 | |
Average heating input power | KW | 9.2 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*800*1230 |
Unit weight | KG | 289 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 10000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size | DN | 32 | |
Max flat square meter | M2 | 300 | |
MODEL | Unit | MD150D | |
Rated heating capacity | KW | 42 | |
Rated Cooling capacity | 29 | ||
Hot water supply | L/h | 1200 | |
Average heating input power | KW | 11 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*800*1230 |
Unit weight | KG | 320 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size | DN | 32 | |
Max flat square meter | M2 | 350 | |
MODEL | Unit | MD200D | |
Rated heating capacity | KW | 72 | |
Rated Cooling capacity | 48 | ||
Hot water supply | L/h | 1590 | |
Average heating input power | KW | 18.2 | |
Rated heating input current | A | 35 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 65 | |
Dimension | W*D*H | mm | 2040×1100×2000 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 20000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max flat square meter | M2 | 600 | |
MODEL | Unit | MD300D | |
Rated heating capacity | KW | 88 | |
Rated Cooling capacity | 65 | ||
Hot water supply | L/h | 24000 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 68 | |
Dimension | W*D*H | mm | 2040×1100×2000 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 30000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max flat square meter | M2 | 730 |
Air to water source hat pump working principle diagarm
Main part diagarm
1. compressor
2. expansion
ABOUT US
1).We were established in 2001.
2).We are a professional heat pump manufacturer, Located around Baiyun Air port
3). We are trading on Meeting Brand ,Meeting heat pump Well-know brand we operate in Europe market
4). Our company has been inspected and certificated by TUV and SGS.
5). We are the one of the first manufacturers whose heat pumps are with top COP gaining grants from Chinese government.
6).We passed ISO 9001 quality management system and ISO14000 environment protection system
7). Our testing laboratory can test heat pump up to 60KW heating capacity and create testing air temperature condition during -25DegC~45DegC,according to EN14511 standard.
9). Our leading products: Air to water heat pump , DC inverter heat pump, High water temperature heat pumps