HVLS INDUSTRIAL CEILING FANS
The wind blown from HVLS industrial ceiling fan feels like natural
breeze system,the wind speed is just the best cool feeling of human
skin. Personnel can feel the temperature difference 5-8 degree,
provide personnel a suitable working environment in hot
summer,improving the production efficiency.
Function of the fan: ventilation | The fan improve air exchange in an entire space, it's perfect
streamlined design can produces 2-3m/s speed three-dimensional
wind, and makes personnel feel like the natural breeze system.It
promotes the dispersion of smoke, moisture, carbon dioxide and poor
air with high specific gravity.So as to improve the quality of
working area, create healthy, dry and safe working environment,
improve working efficiency. |
convenience | It is convenience to be operated, control system adopts the latest
poleless frequency converter control system.besides of convenience
operation, the humanized operation interface also allows you enjoy
the beauty of electronic and mechanic achieve the life. |
Dehumidification | Because it can produce large air volume, effectively promote air
circulation, so that the moisture is well dispersed, greatly
reducing the probability of problems such as bedbugs, fungi and so
on. 4)beautiful and durable After complex surface treatment,the product can avoid the pain of
period cleaning,the cost-performance ratio is the highest,the life
of each fan can reach more than10 years. |
energy saving | The rated power of the motor on the fan is 1.5KW,each fan can cover
1000 square meter working area,8 hours per day, is just 10 degree
power energy consumption,compared to typical small fans and high
power consumption air condition, our industrial ceiling fan can be
called model of energy saving, and greatly reduce your operation
cost. |
DAISEN PRODUCT CATALOG AS BELOW:
Series | Model | Numbers of the blades | Voltage | Power | Diameter | Drive mode | Max speed | Max air volume | Max coverage area(m²) | Fit for installation height(m) | Noise level | Net weight |
DS (Gearbox motor) | DS-7.3 | 6 | 220V/380V | 1.5KW | 7.3M (24FT) | Gearbox motor drive | 50RPM | 888000m3/h | 1200 | 7~18 | ≤60db | 156kg |
DS-6.7 | 6 | 220V/380V | 1.5KW | 6.7M (22FT) | Gearbox motor drive | 52RPM | 822000m3/h | 1000 | 6~15 | ≤60db | 152kg |
DS-6.1 | 6 | 220V/380V | 1.5KW | 6.1M (20FT) | Gearbox motor drive | 55RPM | 774000m3/h | 800 | 6~13 | ≤60db | 147kg |
DS-5.5 | 6 | 220V/380V | 1.5KW | 5.5M (18FT) | Gearbox motor drive | 60RPM | 732000m3/h | 600 | 5~11 | ≤60db | 143kg |
DS-5.0 | 6 | 220V/380V | 1.5KW | 5.0M (16FT) | Gearbox motor drive | 65RPM | 690000m3/h | 450 | 5~9 | ≤60db | 140kg |
DX (PMSM motor) | DX-7.3 | 6 | 220V | 1.5KW | 7.3M (24FT) | brushless direct drive | 50RPM | 888000m3/h | 1200 | 7~18 | ≤38db | 106kg |
DX-6.7 | 6 | 220V | 1.2KW | 6.7M (22FT) | brushless direct drive | 55RPM | 822000m3/h | 1000 | 6~15 | ≤38db | 100kg |
DX-6.1 | 6 | 220V | 1.0KW | 6.1M (20FT) | brushless direct drive | 60RPM | 774000m3/h | 800 | 6~13 | ≤38db | 94kg |
DX-5.5 | 6 | 220V | 0.75KW | 5.5M (18FT) | brushless direct drive | 65RPM | 732000m3/h | 600 | 5~11 | ≤38db | 72kg |
DX-5.0 | 6 | 220V | 0.7KW | 5.0M (16FT) | brushless direct drive | 68RPM | 690000m3/h | 450 | 5~9 | ≤38db | 68kg |
DX-4.2 | 5 | 220V | 0.6KW | 4.2M (14FT) | brushless direct drive | 75RPM | 636000m3/h | 300 | 4~7 | ≤38db | 64kg |
DX-3.6 | 5 | 220V | 0.3KW | 3.6M (12FT) | brushless direct drive | 90RPM | 393600m3/h | 250 | 4~6 | ≤45db | 42kg |
DX-3.0 | 5 | 220V | 0.2KW | 3.0M (10FT) | brushless direct drive | 100RPM | 331800m3/h | 200 | 4~5 | ≤45db | 38kg |
DX-2.4 | 5 | 220V | 0.15KW | 2.4M (8FT) | brushless direct drive | 100RPM | 273000m3/h | 200 | 4~5 | ≤45db | 34kg |
Key component configuration
★ drive device
• DX series fan adopts Taiwan/German gearbox motor
• DX series adopts the industry's first non carbon brush, large
torque, DC drive motor, replacing the traditional motor speed
reducer, realizing high integration, improving reliability and
transmission efficiency
★ control device
• DS series fan adopts Taiwan / Germany brand inverter stepless
speed change (optional explosion-proof controller) to configure
circuit breaker overcurrent overload protection, cooling fan and
other components
• DX series fans adopt a special brush free controller
★ fan blade
• The material of the fan blades adopt magnesium aluminum
alloy T6 treatment, corrosion resistance, high strength, high
toughness
• Advanced fluid simulation software CFD simulation and wind tunnel
test, in line with aerodynamic anti fatigue;
• With the function of delay start, the load and impact of the
motor are greatly reduced, and the service life is longer
★ Structure components
• The structural parts are formed by Q235B laser, bending the
stiffener structure, and the thickest part is 8mm.
• Alloy steel high strength bolts and anti-skid nuts are used for
the bolts.
• Steel wire rope and turnbuckle tension structure to stabilize the
fan against falling
• The integrated chassis can prevent the risk of fracture, the
coupling anti falling structure can avoid screw defects, the
chassis can be dropped, the hole arrangement design of plywood
structure can prevent sliding, the adjustable structure is suitable
for any installation conditions, and the arc-shaped adjustable
waist hole can be adjusted to ensure the plane level of blade
chassis
![Workshop Air Cooling Giant Factory Ceiling Fan/Industrial Fans](http://img.everychina.com/nimg/8d/cc/30e2889e7be167137973a5d6e35e.jpg)
Comparison of three refrigeration methods in 1000 square meter
plant
Refrigeration mode | Quantity | Power/unit | Tall power | General comparison |
Central air conditioner | 1 | 80KW | 80KW | The walls and doors and windows of the plant are required to be
insulated. The cost of one-time investment of the equipment is
high, and the maintenance cost of replacing the filter element and
adding refrigerant is high |
Traditional industrial fan | 40 | 0.3KW | 12KW | The installation of traditional wall fans is limited by walls and
columns. The power lines of floor fans are scattered, which has
potential safety hazards. It is not safe for the hair of staff
members to be mixed into the fan blades, which occupies a small
space and covers a short service life |
7.3M HLVS industrial ceiling fan | 1 | 1.5KW | 1.5KW | Large coverage area, long service life, low maintenance cost,
installation does not occupy the workshop space, safety and
environmental protection |
The energy consumption of large industrial ceiling fan is about 1 /
50 of that of central air conditioner and 1 / 10 of that of
traditional industrial wall fan
What are you looking for? Come and order!