GW9 Series 1000A Outdoor Disconnector Switch Ceramic Made Group
Operated Disconnect Switches For Destribution Equipment
Product Decription:
Outdoor disconnector switch is a type of portable device used for
isolating and grounding electrical distribution lines for
maintenance, repair, or emergency purposes. It is a versatile tool
that can be used in a variety of applications, including overhead
distribution lines, substations, and industrial facilities.
The outdoor disconnector switch is designed to be operated by a
single person, making it easy to use and maneuver. It consists of a
telescoping fiberglass pole, which can be extended to reach the
electrical equipment, and a set of interchangeable attachments,
which allow the user to perform a variety of tasks, such as opening
or closing switches and grounding lines.
The outdoor disconnector switch is designed to provide a visible
break in the electrical circuit, which helps protect against
accidental contact with energized equipment. It is also designed to
withstand harsh environmental conditions, such as high winds, rain,
and snow, making it suitable for use in outdoor environments.
Structure:
This product is composed of base (plate), post insulator,
conductive part and interlock device. One end of the knife is
installed on the dynamic contact knife head through bolts, and the
other end of the knife is separately connected with the static
contact head, and each side is maintained in a good contact state
by the pressure of the compression spring. Each knife is
slot-shaped type, which not only increases the heat dissipation
surface of the knife, but also conducive to reducing the
temperature rise, and improve the mechanical strength of the knife,
making the dynamic thermal stability against short circuit. The
interlocking parts installed at the non-rotating end of the contact
knife and the static locking hook on the static contact constitute
the opening locking device, which is self-locking when the brake is
closed, so that the brake knife will not fall off by itself due to
its own weight or the action of electric power, resulting in the
opening of the brake without cause.
Operation:
1.Closing the Switch: When the switch is closed, the two conductive
parts of the circuit are brought into contact with each other,
allowing electrical current to flow through the circuit.
2.Opening the Switch: When the switch is opened, an air gap is
created between the two conductive parts of the circuit,
effectively isolating the section from the rest of the system. This
is typically done to allow maintenance, repair, or testing work to
be carried out safely.
3.Grounding the Circuit: Before any work can be carried out on the
isolated section of the circuit, it is important to ground the
circuit to prevent any residual electrical charge from building up.
This is typically done using an earth switch or grounding
electrode.
Application:
1.Maintenance and Repair: The Loadbuster Electrical Isolator is
commonly used to isolate and ground electrical distribution lines
for maintenance and repair activities. It allows maintenance
personnel to work safely on energized equipment without the risk of
electrocution.
2.Emergency Response: The Loadbuster Electrical Isolator can be
used in emergency situations, such as power outages or natural
disasters, to isolate and ground electrical distribution lines and
restore power safely.
3.Switching Operations: The Loadbuster Electrical Isolator can be
used to open or close switches and perform other switching
operations on electrical distribution lines.
Technical Parameters:
Serial No. | Parameter | Unit | Data | |||||||||
1 | Rated Voltage | kV | 12 | |||||||||
2 | Rated Current | Model No. | (H)GW9-12(W)/630-20 | A | 630 | |||||||
(H)GW9-12(W)/1000-20 | 1000 | |||||||||||
(H)GW9-12(W)/1250-31.5 | 1250 | |||||||||||
3 | 4s Short-time withstanding current | Model No. | (H)GW9-12(W)/630-20 | kA | 50 | |||||||
(H)GW9-12(W)/1000-20 | 50 | |||||||||||
(H)GW9-12(W)/1250-31.5 | 80 | |||||||||||
4 | Rated Insulation Level | Lightning surge withstand voltage(peak) | Polar-to-Earth (Positive & Negative) | kV | 75 | |||||||
Interfracture (Positive & Negative) | 85 | |||||||||||
Industrial frequency withstand voltage (1 min) (Effective value) | Dry Test/Wet Test | Polar-to-Earth | 42(Dry) 34(Wet) | |||||||||
Interfracture | 48(Dry) | |||||||||||
48(Dry) | ||||||||||||
48(Dry) 40(Wet) | ||||||||||||
5 | Main Circuit Resistance | μ Ω | 630 | |||||||||
1000 | ||||||||||||
1250 | ||||||||||||
6 | Mechanical Life Time | times | 50 | |||||||||
50 | ||||||||||||
80 |