Home Companies GuangDong Heng AnShun Electrical Power Equipment Service Co., Ltd.

High Voltage Outdoor Vacuum Circuit Breaker 50Hz GB1984-2003

GuangDong Heng AnShun Electrical Power Equipment Service Co., Ltd.

Contact Us

[China] country

Trade Verify

Contact name:Sherlin

Inquir Now

GuangDong Heng AnShun Electrical Power Equipment Service Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

High Voltage Outdoor Vacuum Circuit Breaker 50Hz GB1984-2003

Country/Region china
Categories Battery Chargers
InquireNow

Product Details

High Voltage Outdoor Vacuum Circuit Breaker Automatically/Manually Control Vacuum Circuit Breaker

 

Product Description:


 

ZW20-12(F) outdoor vacuum circuit breaker is three phase AC 50Hz outdoor HV switchgear is mainly used for rural and urban 10 kV outdoor distribution network, as a separate and combined load current, overload current, short circuit current and other similar places.

Its whole structure is a three-phase common box type, which is composed of an operating mechanism, a conductive circuit, an insulating system, a sealing element and a shell.

And it is supporting the corresponding intelligent remote terminals to meet the application needs of distribution automation.

· ZW20-12 (Z) Outdoor Intelligent High Voltage AC True Air Breaker with GSM Short Message Function

· Combination with dividing switch controller ZW20-12 (F) Outdoor dividing high voltage AC true air breaker.

 
 
Characteristics of the controller:


 

1.It can be equipped with a 485/232 communication interface, or achieve long-distance monitoring through fiber optics or wireless communication. After reclosing, it has an acceleration function: when the switch recloses due to a permanent fault.

2.When a permanent fault occurs, it automatically accelerates to trip.

3.Remote control/manual reclosing with acceleration to trip, and reclosing interlock: After the user repairs the line and restores power, if they forget to remove the grounding knife switch, it should accelerate to trip.

4.The delay time for reclosing can be adjusted for all three attempts.

5.The trip/reclosing circuit is designed to prevent false operation and has anti-reclosing functionality.

6.Zero-sequence current can differentiate between faults inside and outside the zone.

7.The remote control trip/reclosing adopts a design to prevent false operation.

 
 
 
Application:


 

1.Mining Operations: The ZW20 switch is used in mining operations to control and protect electrical equipment and power distribution networks in underground and surface mines.

2.Data Centers: The switch is utilized in data centers to ensure reliable power distribution and protection for critical IT infrastructure. It enables efficient load switching and safeguards against electrical faults.

3.Oil and Gas Industry: The ZW20 switch finds application in the oil and gas industry for controlling and protecting electrical equipment in refineries, pipelines, and offshore platforms.

4.Infrastructure Projects: The switch is used in various infrastructure projects, such as airports, seaports, and stadiums, for reliable power distribution and protection.

5.Water and Wastewater Treatment Facilities: The ZW20 switch is employed in water and wastewater treatment facilities to control and protect electrical equipment in pumping stations, treatment plants, and distribution networks.

 
 
Structure:


 

1.The controller is a microcomputer-based relay protection and monitoring device.

2.The controller has strong weather resistance and protection against condensation.

3.It is connected to the switch body through aviation connectors.

4.It has good connection reliability and a high protection level.

The controller has four input analog channels: Phase A current, Phase C current, zero-sequence current, and Phase BC voltage. The controller monitors the values of these analog inputs in real-time and compares them with set values to determine line faults and initiate corresponding actions.

 

 

 

 

Environmental conditions:


 

1 ambient air temperature: -40 ° C ~ + 70 ° C;

2 Altitude: not more than 3000 m

3 Ambient air may be contaminated by dust, smoke, corrosive gases, steam or salt spray. Contamination Level: Class IV:

4 Wind speed does not exceed 34 m / s (equivalent to 700 Pa on the surface of the cylinder);

5 Vibration or ground motion from outside the switchgear and control equipment is negligible;

6 The amplitude of induced electromagnetic interference in the secondary system does not exceed 1.6kV.

 
 
 
Technical Parameters:


 

Serial No.ParameterUnitData
1Rated voltagekV12
2Insulation level of FractureWorking Frequency(Dry Test/Wet Test)48
Voltage of Lightning Shock Test (Peak)85
3Level of Insulation to ground/phase to phaseWorking FrequencyDry Test42
Wet Test34
Voltage of Lightning Shock Test (Peak)75
4Rated CurrentA630, 1250
5Rated short-circuit breaking currentkA16, 20, 25
6Rated short-circuit breaking current breaking timestimes30
7Rated short-time withstanding currentkA16, 20, 25
8Rated short-circuit durationS4
9Rated short-circuit closing current (peak)kA40, 50, 63
10Rated peak withstanding currentkA40, 50, 63
11Mechanical lifetimetimesover 1000
12Opening rated current10000
13Net Weightkg180

 

 

 

 

Technical Parameter of Controller:


 

Serial No.ParameterData
1Woking input voltageAC220V
2Input working frequency50Hz
3Allowable voltage fluctuation range for input voltage±20%
4Total power consumption of the device<10W
5Sampling value of phase current input60-600A
6Low voltage operation threshold10-140V
7Allowable sampling error for power input value±5%
8Overcurrent protection delay time value0.1-0.3s
9Setting value for zero-sequence current0.2-6A
10Grounding action delay time0-1200s

 



 

Hot Products

ZW8-12kV Series Outdoor Vacuum Circuit Breaker Stainless Steel Made Outdoor Powerful Vacuum Circuit ...
ZW8-12 Series Outdoor Vacuum Circuit Breaker Intelligent Automatic Vacuum Load Switch Product ...
High Voltage Outdoor Vacuum Circuit Breaker Automatically/Manually Control Vacuum Circuit Breaker ...
High Voltage Outdoor Vacuum Circuit Breaker Intelligent Boundary Vacuum Load Switch For Industrial ...
Industrial Outdoor Vacuum Circuit Breaker Controlled Manually/Automatically Matching With GW9 Series ...
High Voltage Automatic Vacuum Circuit Breaker Outdoor AC Circuit Breaker Used With Group Disconnect ...