Home Companies Thomas T Intelligent Technology Co., Ltd.

Underfloor Heating Valve Actuators 3 Wire Single Control Nut Mounting

Thomas T Intelligent Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.18 Tianzhu Road, Hudai Industrial Park, Binhu District, Wuxi, Jiangsu, China 214161

Contact name:Michael Tang

Inquir Now

Thomas T Intelligent Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Underfloor Heating Valve Actuators 3 Wire Single Control Nut Mounting

Country/Region china
City & Province wuxi jiangsu
Categories Bricks
InquireNow

Product Details

Manual and Automatic Integration Actuator for Floor Heating System

  • Compact and economical
  • Can make the valve power off when fully open or closed.
  • Three installation types: Nut mounting, vertical press way, snap-assembly

 

Model numberZBD230K01
Function3-wire dual control or 3-wire single control
Power supply          230VAC or 24VAC/DC
Power consumption3.5W
Frequency50/60Hz
Running time15s
Torque4Nm
Installation sizeM33x1.5
Protection levelIP42
Thrust100N
Stroke5.5mm

 

Wiring diagram

 

Type of vlaves to be used

Installation typeModel numberThreadDischarge coefficient KvsValue standard pressure MPaShut off pressure difference MPaMedium temperature
Nut mountingBV20-A33/4"7.241.00.15-100°C
BV20-ST13/4"9.301.00.15-100°C
BV25-A21"8.701.00.15-100°C
Vertical press wayVB19F20A3/4"9.781.00.15-100°C
VB19F20B3/4"9.781.00.15-100°C
Snap-assemblyVB18F20B1/2"9.861.00.15-100°C
VB18F20A1/2"9.861.00.15-100°C
U shaped push rod

 

 

Installation notes

 

Before any service work on the final controlling device is carried out, it is essential to isolate the rotary actuator from the power supply (by unplugging the electrical cable if necessary). Any pumps in the part of the piping system concerned must also be switched off and the appropriate slide valves closed (allow all components to cool down first if necessary and allows to reduce the system pressure to ambient pressure level).

The system must not be returned to service until the ball valve and the rotary actuator have been correctly reassembled in accordance with the instructions and the pipeline has been refilled by professionally trained personnel.

 

 

Hot Products

Electric valve actuators control the opening and closing of valves. They can provide linear or ...
2Nm Snap-Assembly Ball Valve Actuator Electric 230V ZBC230K03 3-wire dual control or 3-wire single ...
Manual and Automatic Integration Actuator for Floor Heating System Compact and economical Can make ...
LCD Screen Rotation Function Energy Saving Ball Valve Actuators Product Description: 1.Flexible ...
4Nm Electric Ball Valve Actuator The electric ball valve drive uses metal drive parts to drive the ...
DN20 High Flow Rate HVAC Control 2-Way Brass Ball Valve Matching Valve Application: HVAC Water ...