Yong Xing Boiler Group Co.,Ltd |
|
New Environment Friendly Save Fuel SZL Wood pellets or Coal Fired Steam Boiler For Sale From China Manufacturers
1. Introduction
- The SZL assembled chain grate biomass boiler adopts a double-drum vertical arrangement, and the combustion mode is a chain grate. The rated evaporation is 4~20t/h.
- The boiler is fueled with biomass-forming solid fuel. The water wall of the wall on both sides of the furnace adopts a membrane water wall structure;
- the water wall tubes of the front and rear walls of the furnace extend downward to the upper part of the grate to form front and rear arches, which not only increases the sealing performance of the boiler, but also increases the volume and the heating surface of the furnace.
-The strength of the rear arch is reinforced. The fuel falls from the coal hopper to the grate, and burns after the furnace enters the furnace. The flue gas enters the convection tube bundle area and passes through the smoke-proof wall.
-The flue gas flow turns to the S-shape, and the dust in the flue gas is separated by inertia and falls below. In the four gravity automatic falling hoppers provided, the slag hopper is discharged into the slag hopper with the operation of the grate, and the slag discharge machine discharges the furnace body.
- SZL series assembly chain grate biomass boiler has high
automation level, safe and stable operation, strong fuel
applicability and high smoke emission standard.
- After the furnace, there is a convection tube bundle and an economizer at the tail. The flue gas enters the tail flue through the furnace, the combustion chamber, the convection tube bundle, and the economizer, and is discharged into the atmosphere through the dust collector, the induced draft fan, and the chimney.
-The front wall is equipped with secondary air, controlled by a valve, put into use when burning biomass fuel, strengthens combustion, fully burns the fuel, and improves combustion efficiency. A higher feed port is used to meet the specific needs of biomass fuels.
The more details table about the biomass steam boiler of SZL 2-20t is list below.
Parameters Table for SZL 2-20 ton | |||||||
NO. | Model | SZL2 | SZL4 | SZL6 | SZL10 | SZL15 | SZL20 |
1 | Rated evaporation capacity t/h | 6 | 4 | 6 | 10 | 15 | 20 |
2 | Working Pressure Mpa | 1.25/1.6 | 1.25/2.5 | 1.25/2.5 | 1.25/2.5 | 1.25/2.5 | 1.25/2.5 |
3 | Steam Temperature ℃ | 194/225 | 194/225 | 194/225 | 194/225 | 194/225 | 194/225 |
4 | Thermal Efficiency % | 79.55 | 78.82 | 79.5 | 80.2 | 82 | 82 |
5 | Grate Area ㎡ | 3.22 | 6.72 | 7.52 | 11.8 | 18 | 23 |
6 | Fuel | Biomass/coal | Biomass/coal | Biomass/coal | Biomass/coal | Biomass/coal | Biomass/coal |
7 | Transportation Size m | 5.5×2.35×3.97 | 7.73×2.36×3.52 | 6.15×2.84×3.54 | 7.85×3.32×3.52 | 10×3.2×3.5 | 11×3.2×3.5 |
Kindly send us your inquiry by website or by mailbox.
2. SZL biomass boiler features
1).The convective arrangement has a high heat exchange efficiency
on the heated surface, and the efficiency of the boiler operation
is stable and has a certain overload operation capability;
2).The water circulation system is reasonable, the water capacity
is large, the steam space is large, and the steam quality is good;
3). The cross-section ratio of the falling surface of each heated
surface to the riser tube is reasonable, and the combustion
condition is stable;
4).The front and rear arches are properly matched, the coverage of
the furnace arch is large, the furnace temperature is high, and the
combustible volatiles of coal can be burned when it is greater than
20%;
5). Each air chamber can be adjusted according to the amount of air
required for each combustion stage of the fuel, and there is no
partial burning phenomenon. The lower part of each air chamber is
provided with a pull-type cast iron ash door, which is not easy to
be deformed, convenient to use, and has good sealing performance. .
When the carbon content in the coal slag is not more than 10%, the
thermal efficiency of the boiler is about 82%.
6). Design multiple smoke-proof walls between the convection tube
bundles, so that the flue gas in the combustion chamber enters the
convection tube bundle and perform multiple reentry. During the
reentry process, the smoke and soot in the flue gas and the
smoke-proof wall and the convection tube bundle are used. The
multiple scouring collisions, when the reentry, the flue gas forms
a vortex here, using the inertial force of the flue gas and the
smoke blocking wall, the tube bundle colliding, and the centrifugal
force when forming the vortex to perform dust removal, using this
measure, the initial dust concentration of the boiler body Very
low, it is beneficial to reduce the pollution of boiler smoke to
the atmospheric environment.
3.Description-----Precautions for the use of biomass boilers
1).Before starting the boiler, check the power supply, voltage,
water source, fuel abnormality, close the drain valve, open the
water supply valve, and check whether the flue is unobstructed. In
addition, check the pressure of the furnace body and the operation
of the make-up pump to confirm whether the motor can work normally.
Check the working status of the pump. After all the above devices
have been confirmed, they can be turned on.
2).When the user repairs the boiler or replaces the accessories,
the power must be cut off to avoid danger to the operator.
3).The electric control box, burner, pump motor and other parts
should be protected from moisture ingress to prevent burning, and
the boiler should be kept clean.
4).This product belongs to biomass/fired steam boiler. Please be
sure to install water softener when using this equipment according
to the boiler water quality requirements. Because the hard water
quality will cause boiler fouling, it will cause tube bursting when
it is serious. Shorten the life of the boiler. Failure to use the
water treatment equipment as required to cause damage to the boiler
is not covered by the warranty.
5).Please pay attention to the timed sewage when using the steam
boiler. Discharge at least once a day and discharge at a pressure
of 0.15 MPa to 0.25 MPa. This can effectively prevent pipe
blockage. In addition, the sewage pipe should be connected
according to the regulations, beware of the operator's burns.
TWO PART ASSEMBLED BOILER | ||||||||
boiler model | Unit | SZL6-1.25/1.6-AII | SZL8-1.25/1.6-AII | SZL10-1.25/1.6-AII | SZL12-1.25/1.6-AII | SZL15-1.25/1.6-AII | SZL20-1.25/1.6-AII | SZL25-1.25/1.6-AII |
capacity | ton/h | 6 | 8 | 10 | 12 | 15 | 20 | 25 |
rated pressure | Mpa | 12.5/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 |
rated steam temeperature | ℃ | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 |
feed water temperature | ℃ | 105 | 105 | 105 | 105 | 105 | 105 | 105 |
radiation area | m2 | 18.19 | 22.14 | 25.8 | 25.8 | 34.117 | 53.78 | 99.21 |
convection area | m2 | 121.9 | 158.86 | 200.38 | 250.17 | 331.616 | 411.8 | 457.78 |
economizer area | m2 | 53.13 | 104.64 | 130.8 | 174.4/261.1 | 117.72/117.2 | 212.4 | 476.16 |
valid grate area | m2 | 7.55 | 9.34 | 10.98 | 12.78 | 16.24 | 20.84 | 24.76 |
applicable fuel | COAL | COAL | COAL | COAL | COAL | COAL | COAL | |
exhaust gas temperature | ℃ | 165.78/169.85 | 161/165 | 160/162 | 158/150 | 156.7/159.4 | 153/159 | 152/156 |
design efficiency | % | 80.11/79.44 | 79.95/79.98 | 80.55/80.28 | 80.68/80.72 | 80.48/80.56 | 81.09/80.77 | 81.38/81.26 |
fuel consumption | kg/h | 863.28/874.78 | 1153.42/1161.38 | 1430.96/1442.74 | 1714.5/1721.8 | 2167.89/2164.7 | 2868.63/2884.7 | 3551/3556 |
max part size for delivery | mm | 7100*2800*3500 7300*2540*2330 | 7300*3000*3500 7400*2700*2330 | 7600*3200*3500 7700*2900*2330 | 7600*3200*3500 8500*2900*2330 | 7350*3373*3505 8904*3370*1100 | 7814.7*3573*3511 9439*3768*1100 | 8478*2600*2740 Bulk packing |