Yong Xing Boiler Group Co.,Ltd |
|
6t/h Oil gas commerical hot water boiler lng industrial boiler for package machine industry
The commerical hot water boiler is a kind of hot water boiler. The gas hot water boiler uses gas (such as natural gas, liquefied petroleum gas, city gas, biogas, etc.) as fuel, and heats the water through the burner to realize heating and provide life and bath. Hot water, high boiler intelligence, fast heating, low noise, no dust, is a kind of economical hot-selling boiler that is very suitable for China's national conditions.
The burner gas burner construction consists of the following five
parts:
The function of the air supply system of the air supply system is
to deliver air of a certain wind speed and air volume into the
combustion chamber. The main components are: housing, fan motor,
fan impeller, air gun fire tube, damper control.
Commerical hot water boiler Features:
1. Adopting the normal pressure mode, the boiler is not under
pressure, and the safety factor is high, and there is no danger of
explosion.
2. Designed as a burner-type pyrotechnic tube boiler, the fuel is burned by the burner in a micro-positive pressure in the furnace, the high-temperature flue gas is radiated and heat-exchanged in the furnace, and then enters the convective heat exchange of the pyrotechnic tube, and finally passes through the upper cigarette case. discharge.
3. The boiler body design of the boiler body adopts computer
optimized simulation design, which fully optimizes the size of the
boiler and makes the shape harmonious and beautiful.
4. The flue pipe is inserted with a baffle to slow down the flue
gas discharge speed, strengthen the heat exchange, ensure the heat
generated by the fuel combustion to heat the boiler water to the
greatest extent, and greatly improve the thermal efficiency of the
boiler.
5, equipped with imported brand burners, fully automatic program
control, high degree of automation, the fuel system provides the
fuel needed for combustion, the air supply system sends the
appropriate wind speed, air volume, the ignition system ignites the
mixture of air and fuel, the detection system Ensure stable and
safe combustion of the burner
6. The gap between the large diameter pipe and the large hole
bridge makes the scale coating thin and easy to clean in the same
time. Product map
7, the shell shell furnace large interlayer water jacket, the
boiler water capacity is large, can provide sufficient boiling
water.
8, with multiple safety protection: leakage protection means that
leakage automatically cuts off the power supply; overheat
protection means that when the boiler water temperature reaches the
alarm temperature, the burner is automatically stopped and an alarm
is issued; when the secondary overheat protection means that the
temperature of the boiler casing exceeds 105 °C, it is
automatically cut off. The secondary circuit, the boiler stops
working; the water level detection protection uses the
sophisticated water level electrode rod to monitor the water level
in real time, and the water level is lower than the upper limit
water level solenoid valve until the upper limit water level is
reached.
9, mechatronics design, small size, easy to install and transport.
10. The furnace is specially treated to ensure the water quality is
clean and hygienic.
11, the outer lining aluminum foil glass wool for insulation,
better insulation effect.
12, white color plate packaging, beautiful, clean and rust
resistant.
13. The water supply port is at the lower part, the solenoid valve
automatically replenishes water, and the boiling water in the
boiling water area takes water to eliminate the phenomenon of “hot
and cold water” and “thousand boiling water” to ensure that 100% of
the drinking water is pure boiling water. 14. The boiler can be
used in two machines, which can supply boiling water and provide
hot water.
Commerical hot water boiler Superior performance
1. Boiler patent technology
The fully wet back combustion chamber, the back combustion chamber
and the rear tube plate are butt jointed, and the boiler is 99.9%
full butt welding, with the lowest stress and more reliable
quality.
2. Large diameter corrugated furnace
The boiler combustion chamber is composed of a large-diameter
full-corrugated furnace, which has a large combustion space,
complete combustion of the fuel, effective absorption of thermal
expansion, and large radiation heating surface.
3. Enough heat
The total heating area of the boiler is sufficient to fully
absorb the effective heat, the exhausting temperature is low, and
the heat loss is small, ensuring sufficient output and high
efficiency.
4. Strong heat load adjustment ability
The shell has a large diameter and a large water capacity, and has
strong adaptability to load changes and stable output.
5. Completely solve the problem of too cold boiling of hot water
boiler
The water return system of the hot water boiler is scientifically
arranged, which increases the disturbance of the water side of the
heated surface in the high temperature zone, avoids the phenomenon
of supercooled boiling in the local area, and completely solves the
problem of cracks in the tube sheet and the pipe end of the high
temperature zone.
6. Multi-function safety explosion-proof device The explosion-proof device connected to the furnace on the rear panel of the boiler prevents the high energy generated by the venting moment when the fuel is severely detonated in the furnace, and can be automatically reset. At the same time, it has a sight glass and maintenance. The function of the channel makes use of the adjustment of the combustion flame during operation, and the furnace inspection and maintenance are convenient.
7. Easy maintenance in the pot The top of the boiler is equipped with manholes. The middle and lower parts of the front and rear ends of the boiler are equipped with unique hand hole devices to facilitate inspection and cleaning of the inside of the boiler and the bottom of the boiler.
8. Unique front and rear smoke box seals The smoke box adopts double-opening smoke box door, which is easy to open, multi-stage labyrinth seal, special sealing material, good compressibility, complete barrier of smoke leakage, and can be reused.
9. Reliable pressure and temperature protection Multi-control protection of boiler pressure and water temperature, as well as super-smoke temperature protection to ensure the safety of boiler operation.
10. Leading the level of automatic control The boiler controller adopts Siemens/Delixi electrical components and has reliable performance. The controller has three forms: normal type, Chinese and English menu type with liquid crystal display, and touch screen type for remote control of man-machine dialogue.
Oil water boiler 0.35MW-14MW Oil Gas Fired hot water boiler technical datasheet
Main technical parameters of CWNS oil (gas) atmospheric pressure and pressure hot water boiler | |||||||||||||||
Project model | CWNS, WNS series hot water boiler | ||||||||||||||
Rated calorific value (MW) | 0.35 | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 3.5 | 4.2 | 5.6 | 7 | 8.4 | 10.5 | 12.6 | 14 | |
Working pressure (MPa) | Normal pressure / pressure | ||||||||||||||
Outlet water temperature (°C) | 85/115 | ||||||||||||||
Backwater temperature (°C) | 60/70 | ||||||||||||||
Boiler thermal efficiency (%) | 91—95 | ||||||||||||||
Feed water temperature (°C) | 20 | ||||||||||||||
Fuel consumption | Diesel (Kg/h) | 32 | 65.4 | 98 | 131 | 196.2 | 261.6 | 327 | 392.4 | 523.2 | 654 | 784.8 | 981 | 1177 | 1310 |
Heavy oil (Kg/h) | 34 | 69.5 | 105 | 139 | 208.5 | 278 | 347.5 | 417 | 556 | 695 | 864 | 1042.5 | 1251 | 1390 | |
Natural gas (m3/h) | 39.5 | 79.3 | 119 | 159 | 237.9 | 317.2 | 396.5 | 475.8 | 644 | 793 | 951.6 | 1189.5 | 1427.4 | 1586 | |
Liquefied gas (m3/h) | 14.2 | 29 | 43.5 | 58 | 87 | 116 | 145 | 174 | 232 | 290 | 348 | 435 | 522 | 580 | |
City gas (m3/h) | 84 | 168.5 | 253 | 337 | 505.5 | 674 | 842.5 | 1011 | 1348 | 1685 | 2022 | 2527.5 | 3033 | 3370 | |
Boiler transportation | Length (mm) | 2800 | 3500 | 4100 | 4500 | 4700 | 4550 | 5700 | 6300 | 7000 | 7200 | 7840 | 8100 | 8230 | 8250 |
Width (mm) | 1600 | 1600 | 1900 | 2000 | 2110 | 2210 | 2500 | 2600 | 2700 | 2800 | 2860 | 3100 | 3100 | 3400 | |
High (mm) | 2000 | 2100 | 2310 | 2360 | 2470 | 2580 | 2800 | 2900 | 3200 | 3300 | 3300 | 3400 | 3400 | 3550 | |
Total power consumption (KW) | 2.3 | 6.7 | 11 | 13.5 | 19 | 21 | 23.5 | 26 | 37 | 37 | 42 | 45 | 52 | 52 | |
Chimney diameter (mm) | 250 | 350 | 430 | 450 | 450 | 550 | 650 | 650 | 650 | 800 | 800 | 900 | 1200 | 1200 | |
Shipping weight (T) | 3.2 | 4.7 | 4.8 | 5.4 | 8 | 9.78 | 13.4 | 15.4 | 17.4 | 17.4 | 23.8 | 30 | 31.6 | 34.5 | |
Heating area (m2) | 3000 | 6000 | 900 0 | 1200 0 | 1800 0 | 2400 0 | 3000 0 | 3600 0 | 4800 0 | 6000 0 | 7200 0 | 900 00 | 1080 00 | 1200 00 | |
Water supply capacity (t) | 7 | 15 | 22 | 30 | 45 | 60 | 75 | 90 | 120 | 150 | 180 | 225 | 270 | 300 |
Oil water boiler Vocume hot water boiler
Project / model | ZKW0.7-85/60-Y(Q) | ZKW1.05-85/60-Y(Q) | ZKW1.4-85/60-Y(Q) | ZKW1.75-85/60-Y(Q) | ZKW2.1-85/60-Y(Q) | ZKW2.8-85/60-Y(Q) | ZKW3.5-85/60-Y(Q) | |
Heat medium water capacity (L) | 410 | 520 | 568 | 700 | 830 | 980 | 1250 | |
Rated calorific value (Mw/h) | 0.7 | 1.05 | 1.4 | 1.75 | 2.1 | 2.8 | 3.5 | |
Rated calorific value | 60 | 90 | 120 | 150 | 180 | 240 | 300 | |
Fuel consumption | Light diesel oil (Kg/h) | 64 | 96 | 128 | 160 | 192 | 256 | 320 |
Heavy oil (Kg/h) | 67.3 | 100 | 134 | 168 | 202 | 269 | 363 | |
Natural gas (m3/h) | 165 | 116 | 155 | 193 | 232 | 310 | 387 | |
City gas (m3/h) | 77 | 247 | 330 | 412 | 494 | 659 | 824 | |
Liquefied gas (m3/h) | 29 | 44 | 58 | 73 | 88 | 117 | 146 | |
Heat Exchanger | Material/structure | Stainless steel | ||||||
Working pressure (MPa) | 1 | |||||||
Heating | Maximum calorific value | 36 | 54 | 72 | 90 | 108 | 144 | 180 |
Warm water circulation | 36 | 54 | 72 | 90 | 108 | 144 | 180 | |
Pressure loss | 2.2 | 3 | 2 | 2.6 | 2.5 | 3.5 | 3.3 | |
Heating outlet (DN) | 65 | 80 | 80 | 100 | 125 | 125 | 133 | |
Heating area (m2) | 6000 | 9000 | 12000 | 15000 | 18000 | 24000 | 30000 | |
Special for hot water | Maximum calorific value | twenty four | 36 | 48 | 60 | 72 | 96 | 120 |
Water supply capacity (m3/h) | 6 | 9 | 12 | 15 | 18 | twenty four | 30 | |
Hot water temperature | 50 | |||||||
Pressure loss | 2 | 0.6 | 1.5 | 1.8 | 1.5 | 1.8 | 2 | |
Water outlet diameter (DN) | 40 | 65 | 65 | 80 | 100 | 100 | 125 | |
Voltage | Voltage (V) | 220/380 | ||||||
Total power consumption | 2.2 (2.6) | 3.7 (4.1) | 5.0 (6.5) | 7.5(9) | 11 (2.5) | 15 (16.5) | 18.5(20) | |
Blower power consumption | 2.2 | 3.7 | 5 | 7.5 | 11 | 15 | 18.5 | |
Oil pump power consumption | 0.4 | 0.4 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | |
size | Chimney diameter (mm) | 350 | 350 | 400 | 450 | 500 | 550 | 600 |
Long (m) | 2700 | 3200 | 3400 | 4050 | 4700 | 4900 | 5500 | |
Width (m) | 1365 | 1365 | 1600 | 1600 | 1600 | 1800 | 2020 | |
High (m) | 2345 | 2400 | 2500 | 2580 | 2580 | 2630 | 2700 |