Series resonance test device

 

1. Subject
     1.10kV/300mm2 cable, unit length capacitance 0.37uF/km, cable length 1.4km, tested cable capacitance 0.153uF, test frequency 30-300Hz, test voltage 52kV, withstand voltage time 60min;
     2. 35kV power transformer power frequency AC withstand voltage test, capacitance ≤0.02uF, test frequency 45~65Hz, test voltage not exceeding 68kV, test time 1min;
     3. AC withstand voltage test for switches and transformers with voltage levels of 35kV and below, the test frequency is 30-300Hz, the test voltage does not exceed 100kV, and the test time is 1min;
2. Environmental conditions for device use
     1. Ambient temperature: -5℃—45℃;
     2. Relative humidity: ≤90﹪, no condensation;
     3. Altitude: ≤1000m.
3. The main technical parameters and functions of the system
     1. Rated capacity: 108kVA;
     2. Rated voltage: 27kV; 100kV;
     3. Rated current: 4A; 1A;
     4. Power supply: single-phase 220V±10﹪;
     5. Working frequency: 30-300Hz;
     6. Frequency resolution: 0.1Hz; frequency instability: ≤0.1%;
     7. Working time: 15min continuous operation is allowed under rated power;
     8. Temperature rise: After 15 minutes of continuous operation at rated power, the temperature rise of each part of the device is ≤65K;
     9. Output waveform: sine wave, waveform distortion rate <1%;
     10. Quality factor: the device itself Q≥30 (when f=45Hz);
     11. Protection: with over-current, over-voltage and flashover protection (see the frequency conversion power supply section for auspiciousness);
     12. System measurement accuracy: effective value 1.5.

 

Configuration equipment list

numberEquipment nameModels and SpecificationsunitQuantity
  1.  
Frequency PowerFKVF-6kW/220Vstation1
  1.  
Excitation transformerCQSB(J)-6kVA/1.5×4kV/0.225kVstation1
  1.  
Dry reactorCHX(Jf)-27kVA/27kVSection4
  1.  
Capacitor voltage dividerTRF-100kV/150pFstation1
  1.  
Compensation capacitorBWF-100kV/14.5nfstation1
  1.  
Insulation support set1
  1.  
Equalizing ring set1
  1.  
Wiring set1

Hot Products

Adjusting inductance type series resonance test device 1. Subject For the Suwa Hydropower Station ...
Frequency modulation type series resonance test device 1.Applicable scope of device 1. Meet the AC ...
Series resonance test device 1. Subject 1. 10kV/300mm2 cable 3km AC withstand voltage test, ...
Adjusting inductance type series resonance test device 1. Subject For the Suwa Hydropower Station ...
Series resonance test device 1. Subject 1.10kV/300mm2 cable, unit length capacitance 0.37uF/km, ...
Portable Variable Frequency Resonant Withstand Voltage Test Set , For 35KV Cable and Power ...